• Title/Summary/Keyword: subway system

Search Result 859, Processing Time 0.028 seconds

Case Study on defects of Tunnel Drainage in Subway (지하철의 터널 배수체계에 따른 결함 사레)

  • Kim Suk-Cho;Lee Jae-Uk;Cho Sung-Woo;Shin Yong-Suk
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.292-298
    • /
    • 2005
  • Tunnel in subway should be designed as a water-proof type tunnel as much as possible but it is difficult to make it come true due to several facts, such as construction technique and cost. A drainage type tunnel as a substitute of a water-proof tunnel lead to the increase of water pressure on the concrete lining that make bad effect to tunnel structure when it has some problem to operate the drainage system. Throughout studying about cases on defects of tunnel drainage in subway We hope it contributes to tunnel maintenance.

  • PDF

A Study on the Effect of Corporate Culture on the Organizational Effectiveness. - Focusing on the Case of A Subway - (기업문화가 조직효과성에 미치는 영향 -A지하철을 중심으로-)

  • Shin Tack-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.2
    • /
    • pp.176-181
    • /
    • 2005
  • The purpose of this thesis is, based on the cognitive response of employees, to depict the phenomenon and the pattern of organizational culture in A Subway system, To attain this purpose, several aspects of organizational culture are surveyed through questionaire and analyzed by SPSS. The major findings are . 1) In general, the cognitive response of employees in railway-concerned firms on culture-related aspects is awfully negative. 2) Job satisfaction and involvement in A Subway is highly related to achievement factor in terms of culture. 3) According to the analysis based on four kinds of Job Groups, certain job groups such as drivers and vehicle maintenance are seen as having exceptionally negative attitude towards every aspects of their organization. So, some careful diagnosis and approaches to the symptoms, the causes, and the treatments are urgently needed.

A study on panel structure filter performance of air handling units for subway stations (지하역사 공기조화기 장착용 판넬형 부직포필터 성능 연구)

  • Hwang, Sun-Ho;Bae, Sung-Joon;Shin, Chang-Hun;Park, Youn-Ho;Kwon, Soon-Bark;Kim, Se-Young
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1328-1334
    • /
    • 2010
  • As the life quality is higher and higher, the requirement for the clean air in a subway station is strongly being increased. Therefore, many researches have been performed about that. Seoulmetro has taken many parts and has applied latest products for the higher level of air quality. However, by various kinds of facilities, it is hard to maintain the facilities and verify their performances. Therefore it is better to use qualified air filter system by the performance test at subway stations than to apply newly developed one without any verification. This study is focused on the performance verification for a panel structure, which consists of non-woven fabric, to suggest the standard of air filter systems.

  • PDF

A study on the reorganization of subway station as the extended space of city activities - Focused on the case of Hong-Ik university subway station - (도시 활동의 연장 공간으로서의 지하철역 재구성에 관한 디자인연구 - 홍대 전철역을 중심으로 -)

  • Lee, Sun-Min;Kim, Kwang-Soo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.05a
    • /
    • pp.46-50
    • /
    • 2005
  • In the contemporary city, which is an information-oriented society, human is evolving for responding to the various situation. Because the city has changed into the multi-layered network system, which is different from the paths in the past, the paths in the city have become the usual space of life. The active programmed space which is corresponding to citizen's spontaneous activities should be reflected in the path of city However, the current subway station, which is the main path of the city, is not equipped with the elements responding to the various possibilities of citizens. So this study suggests the programmed station as the extended space of citizen's daily lives.

  • PDF

The Corrosion Control Method for the Stray Current of Subway on Underground Gas Pipeline (지하철의 표유전류에 대한 가스배관의 전식대책법)

  • Ha, Tae-Hyun;Lee, Hyun-Goo;Bae, Jeong-Hyo;Kim, Dae-Kyeong;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.382-384
    • /
    • 2003
  • In case of parallel running with underground gas pipeline and subway, stray current of subway makes a interference on gas pipeline. This interference is one of the reason of gas pipeline corrosion. So, the high speed response rectifier was developed in order to mitigate a interference. In this paper, the field test result of proposed rectifier is presented. The effect of an alternative in stead of the forced drainage system is also presented.

  • PDF

Optimum Support Pattern Design of the Tae-Gu Subway Tunnel (대구 지하철 터널의 적정지보패턴 선정에 관한 연구)

  • 지왕률;최재진
    • Tunnel and Underground Space
    • /
    • v.4 no.2
    • /
    • pp.119-131
    • /
    • 1994
  • This is a Double-Track Railway tunnel in typical Tae-Gu black and gray shale forming part of the No.1 Line of the Tae-Gu Subway. The main fault zone at tunnel is a moderately to highly weathered and closely jointed zone, 0.5 m wide with associated paralled jointing which is slickensided and fractured. After excavation by blasting, the soft rocks should need to be reinforced with optimal supporting pattern which might be better redesigned through the consideration of the results of in-situ rock measurements at the field. Performances fo the field tests included Point Load Test, Schmidt Hammer Test, and field joint measurement gave the detail data for the optimum support design and safe excavation of the No.1 Line of Tae-Gu Subway at the No.1-7 consturction site adn the safety of this redesigned supports system was analysed by the FDM program FLAC.

  • PDF

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.

A Design on the TMS-DCU Interface for Low and High Level Railway Platforms (저상 및 고상 철도 승강장 겸용 승강문 제어유닛과 열차모니터링시스템의 인터페이스 설계)

  • Kim, Chul-Su;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.325-330
    • /
    • 2014
  • In order to operate trains both mainline railroad platform and metropolitan subway line platform, it is necessary to develop the door step equipment of the rolling stock regardless of low(500mm, mainline) and high level platforms(1,135mm, metropolitan subway line) because of the requisite door safety system. In this study, TMS-DCU interface is studied for low and high level railway platforms. As a result, Design circuit of TMS(Train Management System)-DCU(Door Control Unit) interface is suitable for telescopic sliding type doorstep unit to minimize damage to the carbody underframe of railway vehicles.

Introduction of the Intelligent Health Surveillance System for Urban Transit Station (도시철도 정거장의 종합 건전성 감시시스템 개발방향)

  • Shin, Jeong-Ryol;Ahn, Tae-Ki;Park, Kee-Jun;Kim, Jin-Ho;Lee, Woo-Dong
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1248-1253
    • /
    • 2007
  • Urban transit or subway stations generally service for a long period of several decades. And, the urban transit or subway is public transportation which lots of people takes every day. During the service time, they are inevitably damaged from environmental corrosion, material aging, fatigue, and the coupling effects with long-term loads and extreme loads. The included damage accumulates and performance degenerates due to the above factors. They would inevitably reduce the resisting capacity of station against the disaster; even they result in collapse with the structural failure under extreme loads. And, if disaster such as earthquake, fire, etc. happens, it causes huge property damage and threatens the human lives. Because of these above reasons, the intelligent health surveillance system should be researched and developed for ensuring the safety of station. In this paper, the research plans of the intelligent health surveillance system of urban transit station are presented. And also, the development or establishment directions of this system are suggested.

  • PDF

A Study On Gateless Fare Collection System in the Subway (지하철 무개찰 시스템에 관한 연구)

  • Kim, Hyun;Yang, Kyeong-Rok;Oh, Se-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.423-425
    • /
    • 2001
  • In this paper, RF-ID system is used in gateless fare collection for the subway system. This enables passengers to go in and out of stations without any actions specifically for fare collection, such as carrying out from the purse at the gate, throwing tickets into gate machines or moving RF-ID cards near to the card readers. Card check zone system might extract fare from two or more cards that one person carries.

  • PDF