• 제목/요약/키워드: subway

검색결과 2,099건 처리시간 0.05초

모바일 환경센서 모듈을 이용한 지하철 2호선의 공기질 분석 (Air Quality Analysis of Subway Station Line Number 2 Using Mobile Environmental Sensor Modules)

  • 나형욱;김창훈;김규식;김희식;김조천
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.354-356
    • /
    • 2009
  • Air quality analysis is done for subway trains and subway platforms of subway line number 2 using mobile environmental sensor modules. $CO_2$ and PM10/PM2.5 particulate concentration are investigated for screen door systems, under-ground platforms, and transfer stations. These results would help to increase the quality of life of subway railroad passengers.

  • PDF

전철 고상홈 승강장안전시스템 개발시험 (A Study of Safety System for High Platform)

  • 김명룡;권성태;박우현;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.416-421
    • /
    • 2001
  • The subway station platform is designed in high platform for quick getting in/out which is against ordinary train platform. Out of 370 Metropolitan subway station platforms, subway stations which have cured platform are about 38%. In these cases, as the distance between subway and platform would become longer, handicapped people's wheelchairs, baby carriers and old and feeble people can feel uncomfortable when they are getting in and out Also, passengers often fall into track because of the height difference between high platform and track. And if passengers go down on track to pick up something fallen, they sometime fail to climb up and happen to hit against subway. To solve out these kind of inconveniences and prevent accidents, we have developed subway station high platform safety system and finished tests. This safety system is consisted of safety block, screened door and safety wall. This study explained the composition and function of this system and presented the test result to identify its performance.

  • PDF

Assessment of Indoor Air Quality(IAQ), Comfort and Safety in Metro Subway Station

  • Choi, Gi-Heung
    • International Journal of Safety
    • /
    • 제7권1호
    • /
    • pp.39-43
    • /
    • 2008
  • With ever increasing number of citizen using subway stations everyday, safety, health and comfort of passengers and occupants (mostly metro personnel) have become important social issues. Considering the fact that various physical variables and pollutants such as particulate, VOCs and biological agents are closely related to indoor air quality (IAQ) which may cause health problems, a method of quantitative assessment using information-theoretic measure on such variables needs to be devised and implemented for comfort, health and safety of passengers and occupants in the subway station. A basic framework for assessing indoor air quality (for comfort and health) and safety in subway station is suggested. In particular, application of information-theoretic measure for the assessment of indoor air quality, comfort and safety in subway station is discussed. Some examples are presented as well.

지하철 역사에서의 계단 및 개찰구 군중흐름에 관한 연구 (The Study of Crowd Movement in Stair and Turnstile of Subway Station)

  • 김명훈;김응식;조주호
    • 한국안전학회지
    • /
    • 제24권3호
    • /
    • pp.88-95
    • /
    • 2009
  • Most of subway stations are located underground and the number of passengers is far more than that of designed value, therefore the risk of accident is growing bigger and serious damage is expected in case of disaster. In Korea the period of evacuation study is short and numerical and experimental data of evacuation phenomena in subway station is rare. Many egress evaluation depend on foreign commercial S/Ws which are not yet proven its availability in special case such as subway station. In this paper outflow coefficients which are essential in egress evaluation are calculated at train door, stairway and turnstile at 3 most crowed subway stations. This numerical data can be used in prediction of egress evaluation and the result of other prediction methods can be verified with these experimental data.

지하철 터널부로의 열 및 연기배출에 관한 연구 (A Study of Heat and Smoke Exhaust to Subway Tunnel Direction)

  • 이동호
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.1-8
    • /
    • 2004
  • This study aims to derive the operation method of a comprehensive ventilation system which is capable of providing passengers with safe exit paths from platforms in onboard fire situations. To accomplish this, the airflow distributions in subway platforms under 6 types of tunnel vent system were calculated in addition to having analyzed diffusion behaviors of smoke and heat exhaust in such states by performing 6 kinds of different ventilation scenarios in a 3-D Fire Dynamic Simulation (FDS) simulation model. In order to recommend the mechanical smoke exhaust operation mode, Subway Environmental Simulation(SES) is used to predict the airflow of the inlet and outlet tunnel for the subway station to clarify the safety evaluation fir the heat and smoke exhaust on subway fire events.

일본 도시철도 개착식 터널의 내진성능 평가 방법에 대한 고찰 (A Study on Evaluation Method of Seismic Performance on Cut and Cover Tunnel of Subway in Japan)

  • 박범호;이우철;김진호;임남형
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.15-19
    • /
    • 2009
  • Due to the Japan's Kobe earthquake in 1995, a cut-and-cover tunnel, which is one of subway facilities, collapsed unexpectedly. As a result, also in Korea, seismic performance needs to be secured for the cut-and-cover tunnel and currently, the subway seismic design standard is based on the seismic performance. However, there is no standard for the damage level or stability level of a member for securing the seismic performance, and the definition of multi-level seismic performance is not sufficient. By contrast to this situation, in the Japan's evaluation method of seismic performance, design earthquake ground motion having reflected there into the subway driving stability is clearly defined and the seismic performance required for structures is classified in detail. This study analyzes the Japan's systematic evaluation method of seismic performance for cut-and-cover tunnels of subway.

  • PDF

도시철도차량의 내구연한관련 사례분석 (A Case Study on Lifetime for Electric Multiple Units)

  • 정종덕;편장식;박기준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1008-1013
    • /
    • 2008
  • Currently, the use of the subway system as a public transportation has been an increasing demand due to the complex transportation structure in Korea. The subway system provides on time arrival and departure, relatively comfortable riding, and convenient access in the metropolitan area. Among several areas of the operation of the subway system, the safety of subway vehicle itself is of important because the rolling stocks carry the passengers, and the safety and reliability of rolling stocks are directly affected for the safety of subway passengers. In this research, various advanced engineering analysis techniques for the precision diagnosis assessment of subway EMUs have been introduced and the diagnosis assessment results have been used to provide the critical information for the lifetime assessment of EMUs.

  • PDF

지하철 터널내 열차풍 예측 프로그램 개발에 관한 연구 (A Study on the Development of the Train Wind Rate Prediction Program in Tunnel of the Subway)

  • 김종열;최광환
    • 동력기계공학회지
    • /
    • 제3권1호
    • /
    • pp.38-44
    • /
    • 1999
  • Subway is one of the most important transportation and its facilities are increased by the drift of population to cities in these days. But heat generation results from lighting, human and traffic increase in subway, half-closed space, gives uncomfortable sense to the subway passengers. Therefore, natural ventilation by piston effect is done to relieve uncomfortable sense. But train wind by piston effect gives uncomfortable sense to the subway passengers, too. So the numerical calculation of inflow and outflow amounts is important to predict thermal environment and reduce train wind. In case of actual survey of train wind in target station, the amount of train wind are about $3100m^3/train$ at the minimum, about $6000m^3/train$ at the maximum, about $4200m^3/train$ on average. When comparison between simulation for train wind prediction and actual survey for accuracy was done train wind prediction program showed similar results.

  • PDF

도시지하철 진동이 신축예정 건축물에 미치는 영향에 대한 사전환경평가 기법개발 (Development of Pre-assessment Technique for Environmental Impact of Urban Subway Vibration on Newly Planned Buildings)

  • 박상규;이홍기;박원형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1197-1200
    • /
    • 2003
  • Urban subways usually make environmental problems because subway vibrations are transmitted to building structures. However, when the buildings are designed, vibrations due to subway are not usually considered in advance. This results in many environmental vibration problems after buildings are constructed. This study was carried out to set up and evaluate a pre-assessment technique for the environmental impact of urban subway vibration on newly planned buildings near a subway line. for this purpose, semi-emperical method was set up and vibration measurements were made on site in accordance with construction schedule. Computer simulation was also performed using ANSYS software to predict the building vibration and compared with the measured results for evaluation of the pre-assessment technique.

  • PDF

지하철 콘크리트 BOX구조물의 내구성설계에 대한 연구 (A Study of Durability Design in the Subway Concrete Box Structure)

  • 권영찬;김은겸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.940-956
    • /
    • 2004
  • In the course of studying the design of securing the 100-year-long durability of 100 years the subway structure according to the requested service by the Seoul Metropolitan Subway Construction Headquarters, we analyzed 14 construction sites adopting the durability design in subway line No. 9 and concluded as follows: 1. When comparing with 158, the environment index presented for securing 100-year-long durability of subway structure in subway line No. 9, the index of durability was verified as 159.7$\~$179.8 2. When examining the increase value of durability index, we verified that the constructors didn't make various choices in method but they employed the uniformly selected system. 3. Under consideration of the bid form, the construction under bid contract in bulk gave the impacts on the construction cost with attention to selection of the durability index, while the construction under alternative contract in bid adopted uniformly the standard presented by the ordering party.

  • PDF