• Title/Summary/Keyword: stx2

Search Result 128, Processing Time 0.022 seconds

2-Dimensional Moving Particle Simulation for Prediction of Oil Boom Performance in Waves (파랑 중 오일붐 성능 예측을 위한 2차원 입자법 시뮬레이션)

  • Nam, Jung-Woo;Park, Ji-In;Hwang, Sung-Chul;Park, Jong-Chun;Jeong, Se-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.90-97
    • /
    • 2013
  • Oil booms are one of the most widely used types of equipment for the protection of coastal areas against oil spills. In some situations, however, there are several types of oil leaks from the oil boom. Important factors regarding these phenomena include the surrounding ocean environment, such as waves, the density and viscosity of oil, the length of the oil boom skirt, etc. To estimate the performance of the oil boom, it is necessary to predict the behavior of the spilled oil and oil boom. In the present study, the prediction of oil boom performance in waves was carried out using the Pusan-National-University-modified Moving Particle Semi-implicit (PNU-MPS) method, which is an improved version of the original MPS proposed by Koshizuka and Oka (1996). The governing equations, which consist of continuity and Navier-Stokes equations, are solved by Lagrangian moving particles, and all terms expressed by differential operators in the governing equations are replaced by the particle interaction models based on a kernel function. The simulation results were validated through a comparison with the results of Violeau et al. (2007)..

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

Prevalence and Characterization of Virulence Genes in Escherichia coli Isolated from Diarrheic Piglets in Korea

  • Kim, Sung Jae;Jung, Woo Kyung;Hong, Joonbae;Yang, Soo-Jin;Park, Yong Ho;Park, Kun Taek
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.271-278
    • /
    • 2020
  • Enterotoxigenic Escherichia coli is one of the major causative infectious agents of diarrhea in newborn and post-weaning pigs and leads to a large economic loss worldwide. However, there is limited information on the distribution and characterization of virulence genes in E. coli isolated from diarrheic piglets, which also applies to the current status of pig farms in Korea. To investigate the prevalence and characterization of virulence genes in E. coli related to diarrhea in piglets, the rectal swab samples of diarrheic piglets (aged 2 d to 6 w) were collected from 163 farms between 2013 and 2016. Five to 10 individual swab samples from the same farm were pooled and cultured on MacConkey agar plates, and E. coli were identified using the API 32E system. Three sets of multiplex PCRs were used to detect 13 E. coli virulence genes. As a result, a total of 172 E. coli isolates encoding one or more of the virulence genes were identified. Among them, the prevalence of individual virulence gene was as follows, (1) fimbrial adhesins (43.0%): F4 (16.9%), F5 (4.1%), F6 (1.7%), F18 (21.5%), and F41 (3.5%); (2) toxins (90.1%): LT (19.2%), STa (20.9%), STb (25.6%), Stx2e (15.1%), EAST1 (48.3%); and (3) non-fimbrial adhesin (19.6%): EAE (14.0%), AIDA-1 (11.6%) and PAA (8.7%), respectively. Taken together, various pathotypes and virotypes of E. coli were identified in diarrheic piglets. These results suggest a broad array of virulence genes is associated with coliform diarrhea in piglets in Korea.

A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer (비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구)

  • Yeom, Misuk;Lee, Woosuk;Kim, Daesup;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Purpose : For non-small cell lung cancer, if the treatment volume is large or the total lung volume is small, and the tumor is located in midline of patient's body, total lung dose tends to increase due to tolerance dose of spinal cord. The purpose of this study is to compare and evaluate the total lung dose of three dimensional conformal radiotherapy(3D CRT), intensity modulated radiotherapy(IMRT) and volumetric modulated arc therapy(VMAT) using restricted angle for non-small cell lung cancer patients. Materials and Methods : The treatment plans for four patients, being treated on TrueBeam STx($Varian^{TM}$, USA) with 10 MV and prescribed dose of 60 Gy in 30 fractions, 3D CRT, restricted angle IMRT and VAMT radiotherapy plans were established. Planning target volume(PTV), dose to total lung and spinal cord were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV, $V_{30}$, $V_{20}$, $V_{10}$, $V_5$, mean dose for total lung and maximum dose for spinal cord was assessed. Results : Average value of CI, HI and PCI for PTV was $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$ respectively. $V_{20}$ values from 3D CRT, IMRT and VMAT plans were 30.7%, 20.2% and 21.2% for the first patient, 33.0%, 29.2% and 31.5% for second patient, 51.3%, 34.3% and 36.9% for third patient, finally 56.9%, 33.7% and 40.0% for the last patient. It was noticed that the $V_{20}$ was lowest in the IMRT plan using restricted angle. Maximum dose for spinal cord was evaluated to lower than the tolerance dose. Conclusion : For non-small cell lung cancer, IMRT with restricted angle or VMAT could minimize the lung dose and lower the dose to spinal cord below the tolerance level. Considering PTV coverage and tolerance dose to spinal cord, it was possible to obtain IMRT plan with smaller angle and this could result in lower dose to lung when compared to VMAT.

Expressed Sequence Tag Analysis of Toxic Alexandrium tamarense and Identification of Saxitoxin Biosynthetic Genes (독성 Alexandrium tamarense 의 EST 분석 및 삭시톡신 생합성 유전자의 확인)

  • Chang, Man;Lee, Juyun;Chung, Youngjae;Lee, Gunsup;Kim, Dongguin;Lee, Taek-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3582-3588
    • /
    • 2013
  • Expressed sequence tag (EST) library was constructed from A. tamarense. Base sequences of EST clones were analyzed and saxitoxin biosynthesis-related genes were cloned. Sequences of 827 clones were analyzed and 564 EST were functionally clustered using Blast searches against GenBank. Main genes in the EST had functions on cellular organization, cell metabolism, energy, cell cycle and DNA processing, cellular transport and transport, cell rescue, defense, death and aging, and transcription. Moreover, expression of S-adenosylmethionine synthetase and H2A histone family genes were increased in the toxic A. tamarense. These results show that two genes could be a good biomarkers for the detection of saxitoxin biosynthesis in the A. tamarense.

Development of WMLS-based Particle Simulation Method for Solving Free-Surface Flow (자유표면 유동해석을 위한 WMLS 기반 입자법 기술 개발)

  • Nam, Jung-Woo;Park, Jong-Chun;Park, Ji-In;Hwang, Sung-Chul;Heo, Jae-Kyung;Jeong, Se-Min
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.93-101
    • /
    • 2014
  • In general, particle simulation methods such as the MPS(Moving Particle Simulation) or SPH(Smoothed Particle Hydrodynamics) methods have some serious drawbacks for pressure solutions. The pressure field shows spurious high fluctuations both temporally and spatially. It is well known that pressure fluctuation primarily occurs because of the numerical approximation of the partial differential operators. The MPS and SPH methods employ a pre-defined kernel function in the approximation of the gradient and Laplacian operators. Because this kernel function is constructed artificially, an accurate solution cannot be guaranteed, especially when the distribution of particles is irregular. In this paper, we propose a particle simulation method based on the moving least-square technique for solving the partial differential operators using a Taylor-series expansion. The developed method was applied to the hydro-static pressure and dam-broken problems to validate it.

Ejector Optimization for SOFC Anode Off-Gas Recirculation System (SOFC 산화전극 배기가스 순환 시스템을 위한 이젝터 최적 설계)

  • Jo, Sung Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.139-148
    • /
    • 2013
  • In this study, an ejector was designed to recirculate the anodic off-gas of SOFC, and a parametric study of the system performance was conducted at various ejector entrainment ratios. Aspen Plus, a chemical engineering program, was used to calculate the operational conditions of the ejector. To minimize the calculation load of the CFD and to ensure the global optimum, a genetic algorithm and Kriging model were used for the optimization. The optimization results showed that the dominant design variables of the sonic ejector are the throat diameter and the first flow nozzle position. The designed ejector has enough flexibility for different operating conditions of a 1-kW SOFC system. When the ejector was applied to the SOFC, it reduced 56% of the steam and 8.4% of the fuel compared to the reference case.

A Study on the Design Method of Magnetizing Yoke Circuit Constant of 200kJ Magnetizer for Rotor Magnetization of High Capacity Permanent Magnet Motors (고용량 영구자석형 모터의 회전자 착자를 위한200 kJ급 착자기의 착자요크 회로정수 설계 방법에 관한 연구)

  • Jeong Minuk;SoongKeun Lee;GwonHu Baek;TaeKue Kim
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.2
    • /
    • pp.21-30
    • /
    • 2023
  • As the adoption and high-performance enhancement of Electric Vehicles continue, the demand for high-output motors and high-capacity Magnetizer for producing large-scale IPMSM is increasing. The maximum peak current of the magnetization and the capacitor discharge time, which are important factors in the magnetization process, are determined by the circuit constants of the magnetizer. In this paper, we analyze the magnetizing system using MATLAB SIMULINK to design the circuit constant of the magnetizing yoke for magnetizing design and present the design procedure for Design the circuit constant. As a result, the parameters of the magnetizing yoke were derived to be 0.015[ohm] and 0.035[mH] based on the capacitance of 15,000[uF] and voltage of 5,000[V].

Evaluate the implementation of Volumetric Modulated Arc Therapy QA in the radiation therapy treatment according to Various factors by using the Portal Dosimetry (용적변조회전 방사선치료에서 Portal Dosimetry를 이용한 선량평가의 재현성 분석)

  • Kim, Se Hyeon;Bae, Sun Myung;Seo, Dong Rin;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.167-174
    • /
    • 2015
  • Purpose : The pre-treatment QA using Portal dosimetry for Volumetric Arc Therapy To analyze whether maintaining the reproducibility depending on various factors. Materials and Methods : Test was used for TrueBeam STx$^{TM}$ (Ver.1.5, Varian, USA). Varian Eclipse Treatment planning system(TPS) was used for planning with total of seven patients include head and neck cancer, lung cancer, prostate cancer, and cervical cancer was established for a Portal dosimetry QA plan. In order to measure these plans, Portal Dosimetry application (Ver.10) (Varian) and Portal Vision aS1000 Imager was used. Each Points of QA was determined by dividing, before and after morning treatment, and the after afternoon treatment ended (after 4 hours). Calibration of EPID(Dark field correction, Flood field correction, Dose normalization) was implemented before Every QA measure points. MLC initialize was implemented after each QA points and QA was retried. Also before QA measurements, Beam Ouput at the each of QA points was measured using the Water Phantom and Ionization chamber(IBA dosimetry, Germany). Results : The mean values of the Gamma pass rate(GPR, 3%, 3mm) for every patients between morning, afternoon and evening was 97.3%, 96.1%, 95.4% and the patient's showing maximum difference was 95.7%, 94.2% 93.7%. The mean value of GPR before and after EPID calibration were 95.94%, 96.01%. The mean value of Beam Output were 100.45%, 100.46%, 100.59% at each QA points. The mean value of GPR before and after MLC initialization were 95.83%, 96.40%. Conclusion : Maintain the reproducibility of the Portal Dosimetry as a VMAT QA tool required management of the various factors that can affect the dosimetry.

  • PDF

Optimization of the Propeller Steady Performance Behind Wake Field

  • Lee, Wang-Soo;Choi, Young-Dal;Kim, Gun-Do;Moon, Il-Sung;Lee, Chang-Sup
    • Journal of Ship and Ocean Technology
    • /
    • v.11 no.2
    • /
    • pp.10-25
    • /
    • 2007
  • With the sharp increase of the oil price, the issue of the energy saving requires even higher propulsive efficiency of the propellers. Traditionally the propellers have been designed with the criteria such as that of Lerbs optimum based on the lifting line theory and the empirical formulae of Lerbs and van Manen giving relations of the wake pitch with the wake non-uniformity. With the aid of the high speed computer, it is now possible to apply the time-consuming iterative approaches for the solution of the lifting surface problems. In this paper we formulate the variational problem to optimize the efficiency of the propeller operating in the given ship wake using the lifting surface method. The variational formulation relating the spanwise circulation distribution with the propulsive efficiency to be maximized is however non-linear in circulation distribution functions, thus the iterative method is applied to the quasi-linearized equations. The blade shape design also requires the iterative procedures, because the shape of the blade which is represented by the lifting surface is unknown a priori. The numerical code was validated with the DTNSRDC propeller 4119 which is well-known to be optimum in uniform inflow condition. In addition existing (well-designed) commercial propellers were selected and compared with the results of the open water tests and the self-propulsion tests.