A Basic Structural Design for Large Floating Crane (대형 해상크레인의 구조 기본 설계)

  • PARK CHAN-HU;KIM BYUNG-WOO;HA MUN-KEUN;CHUN MIN-SUNG
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.1 s.62
    • /
    • pp.71-76
    • /
    • 2005
  • This paper describes basic structural design for the large floating crane barge of fixed undulation type. Structural analysis was performed separately after dividing the floating crane into two parts, The crane part was composed of jib boom, back stay and back tower and the barge part supported the crane part. The structural strength for jib boom structural members are in compliance with JIS B 8821 and scantling of all barge structural members are in compliance with the requirement of KR (Korean Register of Shipping) Steel Barges and Rules for Classification of Steel Ships. For the structural analysis of large floating crane, MSC/NASTRAN and MSC/PATRAN software were used.

Study on Structural Design and Analysis of Fuel System for Aircraft Auxiliary Fuel Tank (항공기 보조연료탱크 연료시스템 구조 설계 및 해석)

  • Choi, Won;Park, Hyunbum
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.4
    • /
    • pp.60-65
    • /
    • 2019
  • This study did a structural design of a fuel system of auxiliary fuel tank applied to aircraft then analyzed it. The safety of the structural design result was investigated. Aluminum alloy metal structure was applied to the fuel system structure. The structural analysis was conducted using commercial finite element software. The design requirement was maximum accelerate condition of the structure. Therefore, structural design was done considering the maximum accelerate condition.

Pressure Drop and Flow-Induced Vibration Test for the HANARO Non-instrumented Irradiation Test Rig of Annular Fuel Pellet (환형소결체 하나로 조사시험용 무계장 리그의 차압 및 유동유발 진동시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Bang, Jae-Gun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.281-286
    • /
    • 2007
  • Needs of fuel's performance evaluation for the dual-cooled fuel pellet (annular shape) necessitate the irradiation test in the test reactor. Irradiation test rig for the HARARO reactor, which is a special-purposed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this paper, pressure drop and flow-induced vibration test for the newly developed non-instrumented test rig were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin. The spectral response characteristics of the flow-induced vibration of the test rid were also discussed.

  • PDF

Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor (환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험)

  • Lee, Kang-Hee;Kim, Dae-Ho;Chun, Tae-Hyun;Kim, Hyung-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.226-229
    • /
    • 2008
  • To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

  • PDF

Performance Requirement of Cast-in-place Concrete with Sandwich Insulation (타설형 콘크리트 중단열 벽체의 요구성능 분석)

  • Park, Jun-Ho;Yu, Jung-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.10-11
    • /
    • 2014
  • Energy load of building affected by insulation performance of building's exterior. and insulation system can be classify interior insulation, exterior insulation, sandwich insulation according to install place of insulation. but within interior insulation system, corner wall and the cross outer wall-slab insulation part may occur thermal bridges. And then, within exterior insulation system is more superior insulation performance than interior insulation, but it has difficult to apply, easily broken at high building because of strong wind load. And also difficult to maintenance exterior insulation system. So, in this study, to found requirement performance of cast-in-place sandwich insulation system that is superior insulation performance and easy construction and maintenance. requirement performance of cast-in-place sandwich insulation system is 1) To avoid thermal bridges in the insulation performance, 2) Both sides concrete wall can be composite action in the structural performance. Because of this study, can develops cast-in-place sandwich insulation system and this insulation system contribute to improve insulation performance of apartment-house and high building.

  • PDF

Requirement analysis for Development of the Bolt-type Rebar Coupler (볼트 접합형 철근 이음장치 개발을 위한 요구조건 분석)

  • Lim, Chae-Yeon;Joo, Jin-Kyu;Lee, Goon-Jae;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.169-170
    • /
    • 2011
  • In the connection of green frame, the bottom rebar of the precast concrete beam needs joint or anchorage to ensure structural integrity. However, given the characteristics of composite precast concrete joint, enough length over which rebar can be anchored or lap-spliced is not secured. In addition, due to issues with constructability, cost or quality, it is difficult to apply welding or mechanical connection techniques. Therefore, this study analyze the requirement for a bolt-type rebar coupler as a solution for the coupling issue between the lower rebars of green frame beam. The requirement for bolt-type rebar coupler proposed herein will provide basic data for development studies of the rebar coupler.

  • PDF

A Basic Structural Design for large Floating Crane (대형 해상크레인의 구조 기본 설계)

  • PARK CHAN-HU;KIM BYUNG-WOO;HA MUN-KEUN;CHUN MIN-SUNG
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.42-47
    • /
    • 2004
  • This paper describes basic structural design for the large floating crane barge of fixed undulation type. Structural analysis is performed to divide two parts because crane barge is composed two parts, crane part of jib boom back stay and back tower and barge part to support crane part. The structural strength for jib boom structure members are in compliance with JIS B 8821 and scantling of all barge structural members are in compliance with the requirement of KR (Korean Register of Shipping) Steel Barges and Rules for Classification of Steel Ships. For the structural analysis of large floating crane, MSC/NASTRAN & MSC/PATRAN software is used.

  • PDF

Evolution of Tall Building Structures with Perimeter Diagonals for Sustainable Vertical Built Environments

  • Kyoung Sun Moon
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.4
    • /
    • pp.307-320
    • /
    • 2023
  • Tall buildings are built with an abundant amount of materials, including structural materials, coming from our limited natural resources. Tall buildings that began from about 10-story tall office towers have evolved to over 150-story tall mixed-use megastructures. As a building becomes taller, structural material requirement to resist lateral wind loads becomes exponentially larger. Therefore, it is crucial to employ efficient structural systems and optimize their design, which will contribute to sustainable vertical built environments through preservation of resources. Tube type structures with large perimeter diagonals are among the most efficient structural systems for tall buildings. Developments of braced tube, braced megatube, diagrid structures, and their optimal design strategies are reviewed. Superframed conjoined towers, produced by interconnecting multiple clustered braced tubes, are presented as a new design direction to achieve not only structural but also architectural and social sustainable design goals.

A System Development of Generating Ubiquitous Service Scenarios and System Analysis (유비쿼터스 서비스 시나리오 생성 및 시스템 분석 시스템 개발)

  • Lee, Yon-Nim;Jung, Dong-Young;Kwon, Oh-Byung
    • Journal of Intelligence and Information Systems
    • /
    • v.14 no.4
    • /
    • pp.161-178
    • /
    • 2008
  • Development and realization of ubiquitous services in physical space is now in progress to develop ubiquitous smart space (USS). As the development methodologies for USS, scenario development is performed before requirement analysis and design, or vice versa. However, even though lots of redundant elements could be found between scenarios and requirement analysis results, a sort of structural approaches to join them together has been still very rare. Hence, the aim of this paper is to propose a system which generates ubiquitous service senarios and system analysis specifications according to a novel integration methodology. To do so, scenario and requirement analysis are integrated in a structured manner.

  • PDF

Comparative Study on Structural Requirements of Part 23 Normal Category and VLA (Part 23 보통급 비행기와 VLA 비행기의 구조분야 감항기술기준 요건 비교 연구)

  • Kim, Seung-Kyem
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.42-46
    • /
    • 2013
  • In 2010, Airworthiness standard for VLA(Very Light Airplane) category was newly introduced as KAS Part VLA. KAS Part VLA is an adaption of EASA CS-VLA which was developed to reduce unnecessary burden of manufacturer of very light, simple, single-reciprocating-engine/propeller powered airplanes having low stall speeds by tailoring some requirements of Part 23. In this paper, difference and similarity of structural requirements between Part 23 and VLA was analyzed.