Compatibility test of a non-instrumented irradiation test capsule for the HANARO test reactor

환형소결체 하나로 조사시험용 무계장 캡슐의 연구로 설치 적합성시험

  • 이강희 (한국원자력연구원 선진핵연료기술개발부) ;
  • 김대호 (한국원자력연구원 선진핵연료기술개발부) ;
  • 전태현 (한국원자력연구원 선진핵연료기술개발부) ;
  • 김형규 (한국원자력연구원 선진핵연료기술개발부)
  • Published : 2008.11.20

Abstract

To investigate an in-pile behavior of the newly developed DUO fuel pellet, the irradiation test will be carried out in the domestic test reactor. Irradiation test capsule for the HANARO reactor, which is a specially designed equipment used for material, irradiation and creep test, must satisfy the operational requirement on the hydraulic characteristics and structural integrity. In this study, a pressure drop, a flow-induced vibration and a short-term endurance test for the newly developed non-instrumented test capsule were carried out using FIVPET as a out-pile evaluation test. The test results show that the new test rig satisfy the HANARO operational requirement with sufficient margin.

Keywords