• 제목/요약/키워드: structural coupling

검색결과 721건 처리시간 0.027초

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구 (The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator)

  • 이강욱;박정호;장성호;임우택;서정민
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

소결 온도에 따른 0.94(Na0.5K0.5)NbO3-0.06(Sr0.5Ca0.5)TiO3-0.1 MnO2의 압전 특성 (Piezoelectric Properties of 0.94(Na0.5K0.5)NbO3-0.06(Sr0.5Ca0.5)TiO3 with 0.1 MnO2 Addition at Varying Sintering Temperatures)

  • 정혜린;이성갑;이태호;김민호;조예원
    • 한국전기전자재료학회논문지
    • /
    • 제27권1호
    • /
    • pp.14-17
    • /
    • 2014
  • In this study, lead-free Piezoelectric $(Na_{0.47}K_{0.47}Sr_{0.03}Ca_{0.03})(Nb_{0.94}Ti_{0.06})O_3$-0.1 $MnO_2$ ceramics were fabricated using mixed oxide method and the effects of various sintering temperature on the structural and electrical properties were investigated. For the $(Na_{0.47}K_{0.47}Sr_{0.03}Ca_{0.03})(Nb_{0.94}Ti_{0.06})O_3$-0.1 $MnO_2$ (NKN-SCT-$MnO_2$) ceramics sintered at temperatures of $1,025{\sim}1,100^{\circ}C$. The results indicated that all specimens were perovskite single phase formation without any second phase. It has been shown that relative density is increased to increasing sintering temperature. When the sintered temperature at $1,075^{\circ}C$, highest sintered density and maximum value of $4.45g/cm^3$. Average grain size is increased to increasing sintering temperature. The electromechanical coupling factor, dielectric constant, dielectric loss, d33 and curie temperature at the sintering temperature $1,075^{\circ}C$ of NKN-SCT-$MnO_2$ specimens were 0.22, 511, 0.033, 103 and $380^{\circ}C$, respectively.

국부적 불연속을 갖는 도파관을 따라 전파되는 파동에 대한 파수 영역 유한 요소 해석 (Propagation of Structural Waves along Waveguides with Non-Uniformities Using Wavenumber Domain Finite Elements)

  • 유정수
    • 한국음향학회지
    • /
    • 제33권3호
    • /
    • pp.191-199
    • /
    • 2014
  • 파이프, 평판과 같이 단면의 형상이 길이 방향으로 일정한 도파관 구조물을 따라 전파되는 진동의 반사 및 투과 특성은 여러 공학 분야에서 응용되는 중요한 주제이다. 도파관에 조인트 또는 균열 등의 국부적 불연속이 있는 경우, 스펙트럴 요소(spectral element)와 유한 요소(finite elment)를 결합한 SE/FE 방법이 주로 사용되고 있다. 그러나 이 방법은 보 이론에 기반한 스펙트럴 요소가 사용되므로 저주파수 대역 해석에 국한되는 단점이 있다. 고주파수 대역 해석에는 스펙트럴 수퍼 요소(spectral super element)와 유한 요소를 결합한 SSE/FE 방법이 제안되었으나 유한요소와 스펙트럼 요소의 연성으로 인해 많은 연산 시간이 요구된다. 이러한 문제점을 개선하고자, 본 연구에서는 국부적 불연속 구간의 단면이 일정한 경우에 대해 국부적 불연속 구간을 스펙트럴 수퍼 요소로 대체한 SSE/SSE 연성 해석을 시도하였다. 적용 모델로는 국부적 결함을 가진 레일의 파동 반사 및 투과, 그리고 주기적 보강재를 가진 평판의 진동전파에 대해 적용하였다. 결함을 가진 레일의 해석 예를 통해, 본 논문에서 사용한 SSE/SSE 방법과 기존의 SSE/FE 방법의 성능을 비교하였다. 보강재를 가진 평판의 예를 통해서는 반복 구조를 가진 도파관의 파동 전파 특성 해석에 SSE/SSE 방법이 유용함을 확인하였다.

유체 부가질량 및 감쇠 결정시 점성 및 편심 영향에 대한 유한요소해석 (Finite Element Analysis for Evaluation of Viscous and Eccentricity Effects on Fluid Added Mass and Damping)

  • 구경회;이재한
    • 한국지진공학회논문집
    • /
    • 제7권2호
    • /
    • pp.21-27
    • /
    • 2003
  • 일반적으로 유체-구조물 상호작용을 고려한 유체속 구조물들의 지진 및 진동해석에는 주어진 시스템에 대한 유체부가질량을 추정하여 구조물관 연계하는 단순해석 방법을 주로 사용한다. 실제로 유체속 구조물의 응답특성은 유체부가질량 뿐만 아니라 유체점성으로 인한 감쇠영향을 받으며 이들은 모두 연계항을 갖는 복잡한 행렬 형태로 나타난다. 본 연구에서는 비점성 및 점성 유체에 대한 Navier-Stokes 지배방정식의 선형화를 통한 유한요소 정식화를 유도하였다. 이를 이용하여 유한요소 해석 프로그램을 작성하고 6각형 단면특성을 갖는 액체금속로 노심에 대하여 덕트집합체 사이의 유체간격과 레이놀즈수 변화에 따른 유체부가질량과 유체감쇠에 대한 유한 요소 해석을 수행한 결과, 유체간격이 줄어들수록 유체부가질량은 유체점성의 영향을 크게 받고 유체감쇠는 점성으로 인하여 레이놀즈수의 영향을 크게 받는 것으로 나타났다. 또한 편심을 갖는 동축원통에 대한 유한요소 해석결과, 편심이 증가할수록 유체부가질량은 크게 증가하지만 유체감쇠는 편심이 작은 경우 거의 변화가 없으며 어느 일정 수준이상으로 편심이 커질 경우에는 크게 영향을 받는 것으로 나타났다.

HyGIS와 Qual2E의 연계 시스템 개발 (Development of Qual2E Interface System Coupled with HyGIS)

  • 박인혁;김경탁;하성룡
    • 한국지리정보학회지
    • /
    • 제14권2호
    • /
    • pp.96-108
    • /
    • 2011
  • 환경에 대한 관심이 고조되면서 환경용량을 정량적으로 평가할 수 있는 환경모델링에 대한 관심이 고조되고 있다. 환경 모델링, 특히 수질 모의에 있어 GIS는 정량적인 매개변수 추출과 산출 등을 가능케 하는 중요한 툴임에도 불구하고 표준화된 절차 등의 부재로 적용에 어려움을 겪고 있다. 이로 인해 동일한 모델을 사용하여 동일한 지역을 모의하더라도 연구자마다 다른 결론을 내고 있어 정책 입안시 혼란을 가중시키고 있다. 본 연구에서는 1차원 하천수질예측모델인 Qual2E와 수문형 GIS 툴인 HyGIS를 연계하여 시스템을 구축하고자 하였다. 이를 위해 Qual2E 모델의 구조화 분석을 실시하고 기존 모델링 절차를 표준화 하였으며, Qual2E 모형에 최적화된 데이터모델을 설계 구축하였다. 또한 입력파일과 출력파일을 통제할 수 있는 매개변수 산출 알고리즘을 개발하고 구축하였다. 시스템의 구축시 GIS 데이터의 제어는 GDK를 활용하고 GUI 및 기타 시스템 환경은 Visual Basic 6.0을 활용하였다. 개발된 시스템을 활용하여 시험평가를 수행한 결과, 모델 구동시간이 기존 모델링에 비해 최대 3배 이상 단축되는 것으로 나타났으며, 입력파일 오류 등으로 인한 모델수행 장애는 발생하지 않았다.

Step-down Piezoelectric Transformer Using PZT PMNS Ceramics

  • Lim Kee-Joe;Park Seong-Hee;Kwon Oh-Deok;Kang Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권3호
    • /
    • pp.102-110
    • /
    • 2005
  • Piezoelectric transformers(PT) are expected to be small, thin and highly efficient, and which are attractive as a transformer with high power density for step down voltage. For these reasons, we have attempted to develop a step-down PT for the miniaturized adaptor. We propose a PT, operating in thickness extensional vibration mode for step-down voltage. This PT consists of a multi-layered construction in the thickness direction. In order to develop the step-down PT of 10 W class and turn ratio of 0.1 with high efficiency and miniaturization, the piezoelectric ceramics and PT designs are estimated with a variety of characteristics. The basic composition of piezoelectric ceramics consists of ternary yPb(Zr$_{x}$Ti$_{1-x}$)O$_{3}$-(1-y)Pb(Mn$_{1/3}$Nb1$_{1/3}$Sb$_{1/3}$)O$_{3}$. In the piezoelectric characteristics evaluations, at y=0.95 and x=0.505, the electromechanical coupling factor(K$_{p}$) is 58$\%$, piezoelectric strain constant(d$_{33}$) is 270 pC/N, mechanical quality factor(Qr$_{m}$) is 1520, permittivity($\varepsilon$/ 0) is 1500, and Curie temperature is 350 $^{\circ}C$. At y = 0.90 and x = 0.500, kp is 56$\%$, d33 is 250 pC/N, Q$_{m}$ is 1820, $\varepsilon$$_{33}$$^{T}$/$\varepsilon$$_{0}$ is 1120, and Curie temperature is 290 $^{\circ}C$. It shows the excellent properties at morphotropic phase boundary regions. PZT-PMNS ceramic may be available for high power piezoelectric devices such as PTs. The design of step-down PTs for adaptor proposes a multi-layer structure to overcome some structural defects of conventional PTs. In order to design PTs and analyze their performances, the finite element analysis and equivalent circuit analysis method are applied. The maximum peak of gain G as a first mode for thickness extensional vibration occurs near 0.85 MHz at load resistance of 10 .The peak of second mode at 1.7 MHz is 0.12 and the efficiency is 92$\%$.

Wind load and wind-induced effect of the large wind turbine tower-blade system considering blade yaw and interference

  • Ke, S.T.;Wang, X.H.;Ge, Y.J.
    • Wind and Structures
    • /
    • 제28권2호
    • /
    • pp.71-87
    • /
    • 2019
  • The yaw and interference effects of blades affect aerodynamic performance of large wind turbine system significantly, thus influencing wind-induced response and stability performance of the tower-blade system. In this study, the 5MW wind turbine which was developed by Nanjing University of Aeronautics and Astronautics (NUAA) was chosen as the research object. Large eddy simulation on flow field and aerodynamics of its wind turbine system with different yaw angles($0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$ and $45^{\circ}$) under the most unfavorable blade position was carried out. Results were compared with codes and measurement results at home and abroad, which verified validity of large eddy simulation. On this basis, effects of yaw angle on average wind pressure, fluctuating wind pressure, lift coefficient, resistance coefficient,streaming and wake characteristics on different interference zone of tower of wind turbine were analyzed. Next, the blade-cabin-tower-foundation integrated coupling model of the large wind turbine was constructed based on finite element method. Dynamic characteristics, wind-induced response and stability performance of the wind turbine structural system under different yaw angle were analyzed systematically. Research results demonstrate that with the increase of yaw angle, the maximum negative pressure and extreme negative pressure of the significant interference zone of the tower present a V-shaped variation trend, whereas the layer resistance coefficient increases gradually. By contrast, the maximum negative pressure, extreme negative pressure and layer resistance coefficient of the non-interference zone remain basically same. Effects of streaming and wake weaken gradually. When the yaw angle increases to $45^{\circ}$, aerodynamic force of the tower is close with that when there's no blade yaw and interference. As the height of significant interference zone increases, layer resistance coefficient decreases firstly and then increases under different yaw angles. Maximum means and mean square error (MSE) of radial displacement under different yaw angles all occur at circumferential $0^{\circ}$ and $180^{\circ}$ of the tower. The maximum bending moment at tower bottom is at circumferential $20^{\circ}$. When the yaw angle is $0^{\circ}$, the maximum downwind displacement responses of different blades are higher than 2.7 m. With the increase of yaw angle, MSEs of radial displacement at tower top, downwind displacement of blades, internal force at blade roots all decrease gradually, while the critical wind speed decreases firstly and then increases and finally decreases. The comprehensive analysis shows that the worst aerodynamic performance and wind-induced response of the wind turbine system are achieved when the yaw angle is $0^{\circ}$, whereas the worst stability performance and ultimate bearing capacity are achieved when the yaw angle is $45^{\circ}$.

분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성 (Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy)

  • 김우철;배성환;김삼진;김철성;김광주;윤정범;정명화
    • 한국자기학회지
    • /
    • 제17권2호
    • /
    • pp.81-85
    • /
    • 2007
  • 분자선 증착법을 이용하여 MnTe 박막을 Si(100):B 및 Si(111) 기판 위에 성장시켰다. 두개의 K-cell을 사용하여 기판온도 $400^{\circ}C$ 및 Te가 풍부한 조건에서 MnTe 합성이 잘 이루어졌다. 이 경우 증착속도는 $1.1 {\AA}/s$이었고 성장된 층의 두께는 $700{\AA}$ 정도이었다. 합성된 MnTe 박막들에 대하여 X선회절, 초전도 양자 간섭계, Physical Property Measurement System, 홀효과 측정 등을 사용하여 그 구조적, 자기적, 전기적 특성들을 조사하였다. X선회절 측정 결과 Si(100) : B및 Si(111)기판 위에 성장된 MnTe는 다결정성의 hexagonal 구조를 나타내었으며, 자기적, 전기적 특성 측정 결과 분말형태의 MnTe와 비교하여 매우 다른 특성을 나타내었다. Zero-field-cooling(ZFC) 및 field-cooling(FC) 조건에서 취해진 자화율 측정에서 다결정 박막은 21 K, 49K, 210K 근처에서 자기적 전이 현상을 보였으며, ZFC와 FC 자화율 사이의 큰 불가역성이 나타났다. MnTe박막의 5K와 300K에서의 자기이력곡선은 강자성 상태를 나타내었으며 잔류자화값과 보자력은 5 K에서 $M_R= 3.5emu/cm^3$$H_c=55Oe$를, 300 K에서 $M_R= 2.1emu/cm^3$$H_c=44Oe$로 나타났다. 전기수송 특성 측정 결과, 온도에 따른 비저항은 저온에서 Mott variable range hopping 전도특성을 나타내는 전형적인 반도체 성질을 보여주었다.

가정간호사업 운용을 위한 정보전달체계 개발 I (가정간호 데이터베이스 구축과 뇌졸중 환자의 가정간호 전산개발) (Development of the Information Delivery System for the Home Nursing Service)

  • 박정호;김매자;홍경자;한경자;박성애;윤순녕;이인숙;조현;방경숙
    • 가정∙방문간호학회지
    • /
    • 제4권
    • /
    • pp.5-22
    • /
    • 1997
  • The purpose of the study was to development an information delivery system for the home nursing service, to demonstrate and to evaluate the efficiency of it. The period of research conduct was from September 1996 to August 31, 1997. At the 1st stage to achieve the purpose, Firstly Assessment tool for the patients with cerebral vascular disease who have the first priority of HNS among the patients with various health problems at home was developed through literature review. Secondly, after identification of patient nursing problem by the home care nurse with the assessment tool, the patient's classification system developed by Park (1988) that was 128 nursing activities under 6 categories was used to identify the home care nurse's activities of the patient with CAV at home. The research team had several workshops with 5 clinical nurse experts to refine it. At last 110 nursing activities under 11 categories for the patients with CVA were derived. At the second stage, algorithms were developed to connect 110 nursing activities with the patient nursing problems identified by assessment tool. The computerizing process of the algorithms is as follows: These algorithms are realized with the computer program by use of the software engineering technique. The development is made by the prototyping method, which is the requirement analysis of the software specifications. The basic features of the usability, compatibility, adaptability and maintainability are taken into consideration. Particular emphasis is given to the efficient construction of the database. To enhance the database efficiency and to establish the structural cohesion, the data field is categorized with the weight of relevance to the particular disease. This approach permits the easy adaptability when numerous diseases are applied in the future. In paralleled with this, the expandability and maintainability is stressed through out the program development, which leads to the modular concept. However since the disease to be applied is increased in number as the project progress and since they are interrelated and coupled each other, the expand ability as well as maintainability should be considered with a big priority. Furthermore, since the system is to be synthesized with other medical systems in the future, these properties are very important. The prototype developed in this project is to be evaluated through the stage of system testing. There are various evaluation metrics such as cohesion, coupling and adaptability so on. But unfortunately, direct measurement of these metrics are very difficult, and accordingly, analytical and quantitative evaluations are almost impossible. Therefore, instead of the analytical evaluation, the experimental evaluation is to be applied through the test run by various users. This system testing will provide the viewpoint analysis of the user's level, and the detail and additional requirement specifications arising from user's real situation will be feedback into the system modeling. Also. the degree of freedom of the input and output will be improved, and the hardware limitation will be investigated. Upon the refining, the prototype system will be used as a design template. and will be used to develop the more extensive system. In detail. the relevant modules will be developed for the various diseases, and the module will be integrated by the macroscopic design process focusing on the inter modularity, generality of the database. and compatibility with other systems. The Home care Evaluation System is comprised of three main modules of : (1) General information on a patient, (2) General health status of a patient, and (3) Cerebrovascular disease patient. The general health status module has five sub modules of physical measurement, vitality, nursing, pharmaceutical description and emotional/cognition ability. The CVA patient module is divided into ten sub modules such as subjective sense, consciousness, memory and language pattern so on. The typical sub modules are described in appendix 3.

  • PDF