• 제목/요약/키워드: storage materials

검색결과 2,209건 처리시간 0.034초

감마선 처리에 의한 방풍, 백지의 저장성 연구 (Studies on the Storage Characteristics of Angelica dahuricae Radix, Glehnia littoralis Radix Treated with Gamma-irradiation)

  • 김수민;김은주
    • 대한본초학회지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2009
  • Objectives : The purpose of this study is to investigate on storage characteristics of Herbal materials treated with Gamma-irradiation(10 KGy). Methods : This experiments were carried out by field survey and storage characteristics were carried out by physicochemical determination. Results : Antimicrobial activity of oriental medicine materials(Angelica dahurica Radix, Glehnia littoralis Radix) were examined, together with investigation of effects on gamma-irradiation. Oriental medicine materials contaminated in microbial cell were tend to be pinhole in packaging materials(polypropylene) by bug and Larva. At the same time, PVDC (polyvinylldichloride) package also was founded in bug and Larva by microbial contamination during storage in room temperature. Conclusions : In conclusion, it is very desirable to dose gamma-irradiation(10 KGy) in these oriental medicine materials in order to prevent microbial activity.

The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials

  • Nassar, Usama;Flores-Mir, Carlos;Heo, Giseon;Torrealba, Ysidora
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.182-187
    • /
    • 2017
  • PURPOSE. Vinyl polyether silicone (VPES) has a different composition from other elastomeric impression materials as it combines vinyl polysiloxane (VPS) and polyether (PE). Therefore, it is important to study its properties and behavior under different test conditions. This study investigated the dimensional stability of 5 VPES consistencies when stored for up to 2 weeks, with and without using a standard disinfection procedure. MATERIALS AND METHODS. 40 discs of each VPES consistency (total 200) were made using a stainless steel die and ring as described by ANSI /ADA specification No. 19. 20 discs of each material were immersed in a 2.5% buffered glutaraldehyde solution for 30 minutes. Dimensional stability measurements were calculated immediately after fabrication and repeated on the same discs after 7 and 14 days of storage. The data was analyzed using two-way ANOVA with a significance level set at ${\alpha}=0.05$. RESULTS. The discs mean contraction was below 0.5% at all test times ranging from $0.200{\pm}0.014$ to $0.325{\pm}0.007$. Repeated measures ANOVA showed a statistically significant difference after 2-week storage between the disinfected and non-disinfected groups (P < .001). Although there was no statistically significant difference between the materials at the time of fabrication, the contraction of the materials increased with storage for 1 and 2 weeks. CONCLUSION. The dimensional changes of VPES impression discs after disinfection and prolonged storage complied with ANSI/ADA standard. The tested VPES impression materials were dimensionally stable for clinical use after disinfection for 30 minutes in glutaraldehyde and storage for up to 2 weeks.

냉동탑차의 Thermobank 열저장 매체에 따른 냉각성능 비교 (Cooling Characteristics of Refrigerated Vehicles with Heat Storage Materials in Thermobank)

  • 문제철;최광일;오종택;김재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.810-814
    • /
    • 2009
  • A experimental study of a high efficiency transport refrigeration system for sliced-raw fish transportation is presented in this paper. The refrigeration system, that is powered by the car engine, is equipped with heat storage for reverse cycle-hot gas defrost; the stored heat is used during defrost cycle of the system. The heat storage has size $400(L){\times}350(W){\times}250(H)\;mm$ and made of fin-tube heat exchanger. System performance and container operating conditions are experimentally investigated and analyzed under cooling and defrosting conditions with heat storage materials. The water is faster about 30% than paraffin in cooling-down time of heat storage materials with load and unload.

  • PDF

바닥난방시스템 적용을 위한 MPCM 성능평가 (Performance evaluation of MPCM to apply for radiant floor heating system)

  • 정수광;전지수;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.475-479
    • /
    • 2012
  • Thermal energy storage (TES) systems using Microencapsulated phase change material (MPCM) have been recognized as one of the most advanced energy technologies in enhancing the energy efficiency and sustainability of buildings. We examined a way to incorporate MPCMs with building materials through application for wood-based flooring. Wood-based flooring is commonly used for floor finish materials of residential buildings in Korea. However, wood-based flooring has not performed the characteristic of heat storage. This study is aimed at manufacturing high thermal efficiency wood flooring by increasing its heat storage using MPCM. As a result, this study confirmed that MPCM is dispersed well in adhesive through the scanning electron microscopy analysis. From the differential scanning calorimetry analysis, it can be confirmed that this composite has the characteristic of a thermal energy storage material. Also, we analyzed how this composition was formed by physical combination through the Fourier transform infrared analysis. Also, we confirmed the bonding strength of the material by using the universal testing machine.

  • PDF

PCM 함유된 축열석고보드의 열환경특성 (Thermal Environment Characteristic of the Heat Storage Gypsum Board Included with Phase Change Material)

  • 권오훈;윤희관;한성국;안대현;심명진;조성운;박종순;김재용
    • 공업화학
    • /
    • 제21권5호
    • /
    • pp.570-574
    • /
    • 2010
  • 기존 단열재의 주된 기능은 단지 열전달을 차단하는 기능과 건물로부터 열손실을 줄여주는 기능만을 수행했다. 반면, 축열재는 특정온도 범위 내에서 열에너지를 저장 또는 방출함으로써 건물에너지 사용량을 절감할 수 있다. 축열 건자재는 실내 공기온도 변화주기를 효과적으로 조절하여 일정하게 온도를 유지시킬 수 있다. 결과적으로 냉난방시스템 기능을 효율적으로 향상시킬 수 있다. 본 연구는 건축자재로 많이 이용되고 있는 석고보드에 상변화잠열물질을 축열재로 첨가하여 그 물성과 열환경 특성을 파악하였다. 또한 축열 건자재를 활용할 때 발생가능한 문제점을 확인하였다. 마지막으로 TVOC와 HCHO 함량 분석으로부터 오염물질의 배출가능성을 조사하여 축열 건자재의 환경 친화도를 검토하였다.

고성능 이차 전지용 하이브리드 에너지 저장 메커니즘을 위한 고용체 화학 (Hybrid Energy Storage Mechanism Through Solid Solution Chemistry for Advanced Secondary Batteries)

  • 하시온;김경호
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.11-25
    • /
    • 2024
  • Lithium-ion batteries (LIBs) have attracted great attention as the common power source in energy storage fields of large-scale applications such as electrical vehicles (EVs), industries, power plants, and grid-scale energy storage systems (ESSs). Insertion, alloying, and conversion reactions are the main electrochemical energy storage mechanisms in LIBs, which determine their electrochemical properties and performances. The electrochemical reaction mechanisms are determined by several factors including crystal structure, components, and composition of electrode materials. This article reviews a new strategy to compensate for the intrinsic shortcomings of each reaction mechanism by introducing the material systems to form a single compound with different types of reaction mechanisms and to allow the simultaneous hybrid electrochemical reaction of two different mechanisms in a single solid solution phase.

Thermopiezoelectric Cantilever for Probe-Based Data Storage System

  • Jang, Seong-Soo;Jin, Won-Hyeog;Kim, Young-Sik;Cho, Il-Joo;Lee, Dae-Sung;Nam, Hyo-Jin;Bu, Jong. U.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제6권4호
    • /
    • pp.293-298
    • /
    • 2006
  • Thermopiezoelectric method, using poly silicon heater and a piezoelectric sensor, was proposed for writing and reading in a probe based data storage system. Resistively heated tip writes data bits while scanning over a polymer media and piezoelectric sensor reads data bits from the self-generated charges induced by the deflection of the cantilever. 34${\times}$34 array of thermopiezoelectric nitride cantilevers were fabricated by a single step wafer level transfer method. We analyzed the noise level of the charge amplifier and measured the noise signal. With the sensor and the charge amplifier 20mn of deflection could be detected at a frequency of 10KHz. Reading signal was obtained from the cantilever array and the sensitivity was calculated.