• Title/Summary/Keyword: storage heat flux

Search Result 64, Processing Time 0.032 seconds

Study on Ice Making Behavior of Water Solution with Surfactant (계면활성제 첨가수용액의 제빙에 관한 기초연구)

  • ;Hideo Inaba;Akihiko horibe
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1175-1183
    • /
    • 2001
  • Recently, a great attention has been paid to the ice thermal storage system for the purpose of energy saving and reduction in peak electrical demand. In the present study, it has been investigated the freezing behavior of several kinds of water solutions with nonionic surfactant. In order to prevent ice blockage in a cooled pipe, the amount and wall adhesion behavior of ice of the test fluids were observed experimentally under different concentration of water solution with surfactant, temperature of cooled wall, and the shear velocity of test fluids. The results showed that the size of ice crystal became smaller at higher shear velocity at wall. And the lowest limit of wall adhesion of ice in water solution with surfactant was found at 230 W/$m^2$ of heat flux.

  • PDF

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

A study on the relationship between the thermal properties of rock and the enviroment in underground spaces (암반 열물성과 지하공간 환경분석 연구)

  • Lee, Chang-Woo
    • Tunnel and Underground Space
    • /
    • v.6 no.4
    • /
    • pp.335-341
    • /
    • 1996
  • This fundamental study analyzes the relationship between rock thermal properties and psychrometric properties in underground space and has a ultimate goal to develope technologies for predicting major environmental variables. The study is divided into 2 subjects (1) developement of a basic model for predicting temperature and humidity, (2) analysis of the validity of the model through application to a local underground storage space for military supplies. The basic model is built for the network of tunnel-shaped underground spaces. The model takes into account rock thermal properties and changes in moisture content in the air due to condensation/evaporation on the rock surface. Using lumped-parameter analytical method, heat flux from or to the surrounding rock is calculated and then the psychrometric properties(air quantity, pressure, temperature, humidity) are estimated through network simulation. The model can be utilized regardless of the tunnel type. The study site is a local storage space built in rock, mainly granite gneiss and quartz-porphyry. It is a U-shaped tunnel, 593.5m long and 6x6.5m wide. Relative humidity inside has to be strictly controlled under 55% to avoid erosion of a certain types of supplies stored in 6 chambers with the capacity of 300~1.000 ton. The thermal conductivity varies between 2.734 and 2.779W/m$^{\circ}C$ and the thermal diffusivity is in the range of 1.119 and $1.152{\times}10^{-6}\;m^2/s$ the specific heat between 910 and $920\;J/kg^{\circ}C$. Relative errors of the predicted values of dry/wet temperature and relative humidity are 0.8~3.0%, 0~7.5% and 0~7.0%, respectively. Apparent errors associated with the rock surface temperature seems to be partly due to the intrinsic limitations in the infrared thermometer used in this study.

  • PDF

Comparison of Surface Fluxes Based on Landuse Characteristics Near Gangjeong-Goryeong Weir of the Nakdong River (낙동강 강정고령보에서 관측된 플럭스의 지표면에 따른 특성 비교)

  • Kahng, Keumah;Koo, Hae-Jung;Byon, Jae-Young;Park, Young-San;Jung, Hyun-Sook
    • Journal of the Korean earth science society
    • /
    • v.34 no.6
    • /
    • pp.561-574
    • /
    • 2013
  • This study investigates energy fluxes measured near Gangjeong-Goryeong Weir of the Nakdong River of South Korea for more than a year, from July 2011 to September 2012, in order to analyze the applicability of the data for future impact analyses. Each of the two study sites is located in a rural area, surrounded by agricultural fields, and an urban industrial area. Sensible and latent heat fluxes are analyzed according to the wind direction. In the summertime, when the wind blows from the river, sensible heat tends to decrease and latent heat tends to increase at both sites. This result is considered to be caused by moisture transfer from the river. Bowen ratio, energy balance closure, momentum flux, and stability are analyzed as well. The Bowen ratio of the rural agricultural site turns out higher than that of the urban site regardless of the season. The energy balance closure is higher at the agricultural site compared to the urban area, which is mainly due to exclusion of the storage term calculation at the urban site. The momentum flux is greater at the urban site both in winter and summer. The instability lasts longer during daytime and in the summertime, when there is a strong turbulence. The data from these sites are appropriate to be used in analyzing the impact of river in surrounding areas for future studies.

Quality Control and Characteristic of Eddy Covariance Data in the Region of Nakdong River (낙동강 유역에서 관측된 에디 공분산 자료의 품질 관리 및 플럭스 특성)

  • Lee, Young-Hee;Lee, Byoungju;Kahng, Keumah;Kim, Soo-Jin;Hong, Seon-Ok
    • Atmosphere
    • /
    • v.23 no.3
    • /
    • pp.307-320
    • /
    • 2013
  • We performed comprehensive quality control for eddy-covariance measurements from 3 farmland sites and 1 industrial site adjacent to Nakdong river. The quality control program is based on Foken and Wichura (1996) and Vicker and Mahrt (1997) and we added criteria for trend and standard deviation for scalar variables and modified criteria for non-stationarity condition of Foken and Wichura (1996) to consider random error of fluxes. The classification of data quality is designed for the raw data and the processed flux data, separately. Use of added criteria efficiently reduces the number of outlier for water vapor and $CO_2$ fluxes and use of modified criteria for non-stationarity reduces the number of outlier for scalar fluxes and increases the number of data with accepted quality for further work. Energy balance ratio is higher in farmlands than industrial site, which is due to neglect of heat storage term in industrial site. Among farmland sites, C4 site shows higher energy balance ratio than other sites. This is due to more homogeneous surface of C4 site than other farmland sites. However, energy balance ratio is very low or even negative at night. Mismatch between the flux footprint and the other energy component footprint over the heterogeneous surface is main cause for energy imbalance at night. Other possible causes are also discussed.

Effect of Pressurization and Cooling Rate on Dissolution of a Stationary Supercooled Aqueous Solution (정지상태 수용액에서 가압과 냉각속도가 과냉각해소에 미치는 영향)

  • Kim, Byung-Seon;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.850-856
    • /
    • 2007
  • In a supercooled or capsule type ice storage system, aqueous solution (or water) may have trouble with non-uniform dissolution though the system contributes to the simplicity of system and ecological improvement. The non-uniform dissolution increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to observe the supercooled state, a cooling experiment was performed with pressurization to an ethylene glycol(EG) 3 mass% solution in stationary state. Also, the effect of the pressurization from 101 to 505 kPa to the dissolution of supercooled aqueous solution was measured with the dissolution time of the supercooled aqueous solution at a fixed cooling rate of brine. At results, the dissolution of supercooled point decreased as the pressure of the aqueous solution in the vessel increased. Moreover, the dissolution point increased as the heat flux for cooling increased.

A Study on Insensitive Munition Test and Evaluation for Solid Rocket Motor (고체추진기관 둔감시험 평가 기법에 관한 연구)

  • Lee, Do-Hyung;Kim, Chang-Kee;Lee, Hwan-Gyu;Yoo, Ji-Chang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.129-132
    • /
    • 2010
  • The objective of IM rocket motor is to minimize the probability of inadvertent initiation and severity of subsequent collateral damage, hence it is important to define personnel and equipment survivability to a rocket motor accident. The violent response probability associated with shock, impact and thermal effects be minimized. And during production, transportation/storage and stack of rocket motor, sympathetic detonation, giving severe effects of the propagation of adverse reaction on its surroundings, be reduced. Hence Reaction type also based on reaction results of the overpressure, fragment throw and heat flux.

  • PDF

Ice Formation on the Outer Surface of a Vertical Tube with Inside Refrigerant Boiling (관 내부 냉매비등이 있는 수직관 외부 얼음 형성 연구)

  • Nguyen, Minh Phu;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.129-135
    • /
    • 2011
  • An ice-making model has been developed and analyzed in this study. The effects of the following on the ice formation on the outer surface of a tube in which a refrigerant flows and boils are numerically investigated: thermal resistance of the refrigerant and thermal resistance of the ice formed on the outer surface of the tube. The ice thickness and related variables are analyzed in the case of the refrigerants R22 and R134a by using the expressions for phase-change heat transfer and boiling heat transfer coefficient. Vapor qualities of the refrigerants range from 0 to 0.8. As a result, up to the first 30 min, the internal convection resistance is higher than the thermal resistance of the ice on the external surface of the tube. However, after about 30 min, the thermal resistance of the ice increases remarkably due to the increase in the ice thickness. Thus, the heat flux to the refrigerant decreases, and further, the refrigerant quality and the boiling heat transfer coefficient also decrease. As the heat transfer coefficient of R22 is higher than that of R134a, the mass of the ice formed when R22 is used is higher than that formed when R134a is used.

Experimental validations of fire-resistant materials for protecting LPG small storage tank from building fires (건물 화재 시 LPG소형저장탱크 보호용 화재 저항 재료 성능 실증)

  • Kim, Seung-Hwan;Kim, Kyung-Sik;Heo, Seung-Geon;Lee, Jae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.18-24
    • /
    • 2020
  • The purpose of this study is to validate thermal hinderance effects, i.e., feasibilities, of fire-proof structure for LPG tank exposed to fire from adjacent burning building. The panel materials suggested for the fire-proof structure are (1) 10 mm-thick wood, (2) wood with fireproof coating, (3) 75 mm-thick Expanded Polystyrene, (4) 75 mm-thick glass wool filled sandwich panel, and (5) 75 mm-thick autoclaved lightweight concrete. The square planar fire source of 1 ㎡, a matrix of nozzles releasing 120-140 g/s of LPG, is used to heat up the wall and the tank beyond, mimicking heat transfer from burning exterior wall finishes. The feasibility is tested by inspecting structural integrity after test, and then by examining temperatures at both sides of panels and tank's front surface as well as heat fluxes. As a result, it can be concluded that, among the suggested sample materials, fire-proof wall with ALC panel only showed the feasibility for explosion prevention with the proven evidences of structural integrity and least increase in temperature of tank.

Measurements of Wet Canopy Evaporation in Forests: A Review (산림에서의 젖은 군락 증발 관측: 고찰)

  • Kwon, Hyo-Jung
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.2
    • /
    • pp.56-68
    • /
    • 2011
  • Wet canopy evaporation ($E_{WC}$) has been recognized as a significant component of total evapotranspiration, especially in forests and therefore it is critical to accurately assess $E_{WC}$ to understand forest hydrological cycle. In this review, I focused on the measurement methods and evaluating the magnitudes of $E_{WC}$ at diverse forest types (e.g., deciduous, coniferous, mixed, and rain forests). I also present the general issues to be considered for $E_{WC}$ measurements. The commonly used measurement methods for $E_{WC}$ include the water balance, energy balance, and the Penman-Monteith (PM) methods. The magnitudes of $E_{WC}$ ranged from 5 to 54% of precipitation based on the literature review, showing a large variation even for a similar forest type possibly related to canopy structure, rainfall intensity, and other meteorological conditions. Therefore, it is difficult to draw a general conclusion on the contribution of $E_{WC}$ to evapotranspiration from a particular forest type. Errors can arise from the measurements of precipitation (due to varying wind effect) and throughfall (due to spatial variability caused by canopy structure) for water balance method, the measurements of sensible heat flux and heat storage for energy balance method, and the estimation of aerodynamic conductance and unaccounted sensible heat advection for the PM method. For a reliable estimation of $E_{WC}$, the combination of ecohydrological and micrometeorological methods is recommended.