• Title/Summary/Keyword: stimulator

Search Result 335, Processing Time 0.023 seconds

Thermal Stimulation System for Meridian point (경혈 열자극 시스템)

  • Yang, S.Y.;Huh, W.;Kim, J.K.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.223-226
    • /
    • 2001
  • In this paper, we devised electrical thermal stimulator for meridian point. The system consist of has four channel applicator, power controller and computer. The applicator consist of resistance wire heater and thermal sensor. A stimulation patterns are obtained from a real moxa combustion. The developed system does not make any smog, does not need moxa anymore, only need electricity.

  • PDF

The Development of Virtual Reality Therapy(VRT) System for the Treatment of Acrophobia (고소공포증의 치료를 위한 가상 현실 시뮬레이터의 제작)

  • Paek, Seung-Eun;Ryu, Jong-Hyun;Beack, Seung-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.10
    • /
    • pp.486-493
    • /
    • 2001
  • Acrophobia is an abnormal fear of heights. Medications or cognitive-behavior methods have been mainly used as a treatment. Lately the virtual reality technology has been applied to that kind of anxiety disorders. A virtual environment provides patient with stimuli which arouses phobia, and exposing to that environment makes him having ability to over come the fear. In this study, the elevator stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a feel of phobia and without phobia, heart rate was measured during experiment. And also measured a person's HR after the virtual reality training and in a real building elevator. In this study, we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

A Study on Analysis and 3D Web Environment for the Treatment Alcoholism (알코중독 치료를 위한 Web 환경 시스템과 분석에 대한 연구)

  • Paek, Seung-Eun
    • The Journal of Information Technology
    • /
    • v.9 no.1
    • /
    • pp.9-19
    • /
    • 2006
  • Medications or conitive-behavior methods have been mainly used as a treatment of alcoholism. lately the virtualy technology has been applied to the kink of alcoholic disorders. A virtual environment makes him having avility to over come the drink. In this study, we were implemented by making panorama images and 3D object modules using 3D MAX, VRML, JAVA. And the BAR stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a alcoholism and without a liquor bottle, heart rate was measured during experiment, and also measured a person's HR after the virtual reality training. The system measures the Physiological signals such as ECG, Temperature, analyzes those data automatically. The system has two parts, one is physiological data acquisition part which gets the body signal, and the other one is mobile nuit which includes signal processing and transmission functions, And Bluetooth allows two parts to communicate with each other. we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

An electric pulp tester using a constant current source (정 전류원 이용한 치수(齒髓) 검사기)

  • Kim, J.S.;Nam, K.C.;Kim, S.C.;Lee, S.J.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.720-723
    • /
    • 2003
  • Electric stimulation of teeth is used for assessing pulp vitality. Because of very high and wide range of impedance of the enamel, electric pulp testers use high voltage, high output impedance and alternative current source. Most pulp testers use voltage stimulation method and their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation in enamel thickness. In this study, we constructed a constant current source type of pulp tester with the maximum current of 150 uA.

  • PDF

Screening of the Extracts of Herbal Medicines which Stimulate the Hydrolysis of Phosphoinositides in Jurkat T-lymphocyte Cells (Jurkat T 면역세포에서 Phosphoinositides의 가수분해를 증가시키는 약용식물 추출물의 검색)

  • 민도식;이영한;백석환;서판길;류성호
    • Biomolecules & Therapeutics
    • /
    • v.4 no.2
    • /
    • pp.148-153
    • /
    • 1996
  • Activation of the T lymphocytes results in a variety of early biochemical events ultimately leading to cell proliferation and lymphokine production. Stimulation of the signal transduction cascade in T cells through the T cell receptor coincides with activation of the phosphatidylinositol-phospholipase C (PI-PLC) pathway. Therefore, we have established a model system to screen immune-simulator that can increase the hydrolysis of phosphoinositides in human T cell leukemia Jurkat cells. As a result of screening from herbal medicine extract, 4 extracts (O1ibanum, Ephedrae Herba, Real Gar, Saussureae Radix) were found 14 increase the production of inositol phosphates. All the active fraction from the four kinds of extract were fluted in a different retention time on C-18 HPLC and these active fraction also showed difference in cell specificity. And all the active fractions increased DNA synthesis in T cell. Therefore, it is suggested that the active fraction among 4 extracts might contain a compound having different properties one another.

  • PDF

Development of Medical System using Time-varying Magnetic field (시변 펄스형 자기장 의료기기 시스템)

  • Kim, In-Soo S.;Hong, Jung-Hwang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2343-2351
    • /
    • 2007
  • In this paper, we describe the design and implementation of time-varying magnetic field stimulator. Novel design for power supply part to generate high repetitive magnetic field for very short time(less than $300{\mu}s$) was achieved. Using the novel designed power supply part and the circular type coil probe, we've achieved high magnetic field up to 1.2 Tesla in 20Hz repetition rate.

Treatment of an Atrophic Scar with Fractional Carbon Dioxide Laser-assisted Poly-L-lactic Acid Delivery

  • Kim, Wan Jin;Jung, Ha Rin;Lee, Sang Ju;Cho, Han Kyoung
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.181-184
    • /
    • 2021
  • Scars can cause great psychological stress among patients. Currently, there are numerous topical agents, laser and surgical treatments available for skin rejuvenation and scar minimization. Laser-assisted drug delivery (LADD) is a treatment method that increases drug delivery by stimulating the skin physically and chemically to enhance the penetration of topical agents. This is one of the areas of great interest in the treatment of various skin diseases in addition to its use for cosmetic purposes. In particular, LADD is relatively non-invasive and has advantages in terms of accessibility and stability. Poly-L-lactic acid (PLLA) is a collagen stimulator known to gradually restore skin volume by inducing inflammation and fibroplasia. Herein, we report a case of treatment of an atrophic scar with fractional carbon dioxide laser-assisted PLLA delivery.

Acupuncture Analgesia in Total Thyroidectomy for Graves' Disease: A Case Report

  • Dong Phuong Tran
    • Journal of Acupuncture Research
    • /
    • v.40 no.4
    • /
    • pp.377-381
    • /
    • 2023
  • This study included a 42-year-old female farmer with a 2-year history of Graves' disease who visited the hospital for a total thyroidectomy for her grade III goiter based on World Health Organization classification. Besides Hegu (LI4) and Neiguan (PC6), extensively used for acupuncture analgesia in thyroid surgery in previous studies, three additional acupuncture points for acupuncture analgesia in thyroidectomy were evaluated in this study: Shuitu (ST10), Quepen (ST12), and Yifeng (SJ17). In this case, we used an electroacupuncture stimulator to stimulate the acupuncture points and combined acupuncture analgesia with diazepam and atropine sulfate administration as adjunct medications to calm the patient. The operation was completed without any complications. The findings revealed that stimulating the five acupuncture points, i.e., Hegu (LI4), Neiguan (PC6), Shuitu (ST10), Quepen (ST12), and Yifeng (SJ17), for acupuncture analgesia combined with adjunct medications is safe for maintaining an adequate level of analgesia and hemodynamic stability during thyroidectomy.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF