• Title/Summary/Keyword: step-through test

Search Result 585, Processing Time 0.032 seconds

Durability Evaluation of Platform Safety Step System (승강장 안전발판 시스템의 내구성 평가)

  • Park, Min Heung;Kwak, Hee Man;Kim, Min Ho
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate durability of platform safety step system in railway. Method: We performed finite element analysis & durability analysis of platform safety step system with VPD (Virtual Product Development) techniques and examined the durability standard & qualification life through the rig test during no failure test time in reliability qualification test. We continued to test 1 million cycles in KRS (Korea Railway Standard) for system's robust design performance. Result: FEM analysis results are 14.9MPa & 14.7MPa of pin-joint, pivot and durability analysis result is above 1 million cycles. we calculated theoretically no failure test time 855,000 cycles and through the 1 million cycles durability rig test in KRS standard we confirmed product quality. Conclusion: This platform safety step system was designed very safe in terms of a mechanical strength & durability.

Clinical Criteria to Perform the Step through Step Gait with a Cane in Chronic Stroke Patients

  • Kim, Won-Bok;Lee, Jung-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.3
    • /
    • pp.285-291
    • /
    • 2014
  • PURPOSE: The purpose of this study was to propose clinical criteria to differentiate patients who are able to perform the step-through-step gait pattern in chronic stroke patients. METHODS: Sixty patients with chronic stroke patients participated this study. To differentiate patients who could perform the step-through-step gait pattern, age, gender, and causes of stroke were noted, a Chedoke-McMaster (CM) damage list, Fugl-Meyer (FM) assessment scales and the Berg Balance Scale (BBS) were determined. A 10 meter gait test and Timed Up and Go (TUG) test were conducted to determine the differences in gait speed and dynamic balance between patients walking with or without canes in the step-through-step gait pattern group. RESULTS: There was no significant statistical difference in age, gender, and stroke type between all subjects. There were significant differences in the CM scale for postural and lower extremities, and FM scale for lower extremities and BBS. The dynamic balance ability and gait speed showed significant differences between the subjects in the step-through-step gait pattern with or without a cane during gait. CONCLUSION: CM and FM scales for the lower extremities and postural control, as well as BBS scales, can be used as criteria to differentiate patients who are able to perform the step-through-step gait pattern. These results can also be used to provide beneficial information to patients that are walking with canes.

Design of bivariate step-stress partially accelerated degradation test plan using copula and gamma process

  • Srivastava, P.W.;Manisha, Manisha;Agarwal, M.L.
    • International Journal of Reliability and Applications
    • /
    • v.17 no.1
    • /
    • pp.21-49
    • /
    • 2016
  • Many mechanical, electrical and electronic products have more than one performance characteristics (PCs). For example the performance degradation of rubidium discharge lamps can be characterized by the rubidium consumption or the decreasing intensity the lamp. The product may degrade due to all the PCs which may be independent or dependent. This paper deals with the design of optimal bivariate step-stress partially accelerated degradation test (PADT) with degradation paths modelled by gamma process. The dependency between PCs has been modelled through Frank copula function. In partial step-stress loading, the unit is tested at usual stress for some time, and then the stress is accelerated. This helps in preventing over-stressing of the test specimens. Failure occurs when the performance characteristic crosses the critical value the first time. Under the constraint of total experimental cost, the optimal test duration and the optimal number of inspections at each intermediate stress level are obtained using variance optimality criterion.

Test Rally to Exchange Product Model (제품 모델 교환 테스트 랠리)

  • 박상호;이병훈;김준형;한순흥;유상봉
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • CAD systems have been developed with network technology and it is needed to exchange product data among them. STEP becomes world-wide international standard to exchange CAD data among various heterogeneous CAD systems in manufacturing industrial fields. We report results to test errors that can happen when exchanging STEP files of product model through the STEP translator of different commercial CAD systems. Also the tests of Korean Character, Hangul, have been carried out. And also we report the STEP rallies held twice in Korea and several rounds abroad, and their testing results are shown as tables and graphs. The tested results can be used for exchanging product models to the next domestic STEP Rally and extended to Northeastem Asian STEP rally by steadily contacting with the organizations for Asian STEP centers such as JSTEP(Japan) and CSTEP(China). Finally we expect that the result can be used to specify STEP standardization in the field of managing product data.

Effects of Red Ginseng Extract Including Vitamin B Groups on Learning and Memory in Mice (비타민 B군이 함유된 홍삼 추출물이 학습 및 기억에 미치는 영향)

  • 김학성;장춘곤
    • Journal of Ginseng Research
    • /
    • v.20 no.3
    • /
    • pp.226-232
    • /
    • 1996
  • This study was performed to investigate the effect of red ginseng extract including some vitamin B groups as test drug on learning and memory in mice. Single and repeated administrations of the test drug improved the acquisition and the process of consolidation in the tests using step-through and step-down apparatus, indicating this test drug improved learning and memory. However, the test drug did not improve scopolamine-induced amnesia. These results suggest that test drug may be useful as a nootropic agent.

  • PDF

Bearing Capacity Estimation of Tapered Pile Using Step-wise shape (등가변형을 이용한 테이퍼 말뚝의 지지력 산정)

  • Jun, Sung-Nam;Seo, Kyoung-Bum;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.490-495
    • /
    • 2009
  • In this study, estimate solution of ultimate axial capacity for axial loaded pile is proposed using step-wised shape. This is verified for effective appling on realistic factor by calibration chamber tests. Estimation method of ultimate axial capacity in this study is verified by calibration chamber test. The results of ultimate axial capacity through this proposed method have sufficiently low standard derivations and COVs. Also, this is verified through test that method is similarly resulted with measured values.

  • PDF

EFFECT OF "STEP-DOWN" AND "BALANCED FORCE" PREPARATION METHODS ON THE SHAPE OF THE ROOT CANAL (Step-down과 Balanced force 근관성형술식에 의한 근관 형태의 변화)

  • Chin, Cheong-Hee;Kim, Jong-Hwa;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.768-779
    • /
    • 1995
  • This study was performed to investigate the effect of root canal shaping techniques on the change of the shape of prepared root canal. 40 mesiobuccal canals of recently extracted mandibular 1st and 2nd molars were divided into 4 groups and shaped by step-down/balanced force technique, step-down/step-back technique, step-back technique and conventional technique respectively. The change of the shape of root canal was traced by superimposing the radiographs obtained before and after shaping of each root canal. The results were as follows. 1. By the experimented techniques except conventional technique, the root canals were more shaped in convex side of apical area and in concave side of most curved and coronal area than in the other sides(P<0.05). By conventional technique, the root canals were more shaped in convex side than in convave side from apex to orifice(P<0.05). 2. By step-down/balanced force technique, the cancave sides at C and D points of proximal view and C point of clinical view were more shaped than the convex side(P<0.05). Through the entire canal, the concave side was more shaped than the convex side in proximal view(P<0.01). But there was no statistical difference between both sides in clinical view. 3. By step-down/step-back technique, the change of root canal shape was not statistically different in concave and convex sides at each point of both views(P>0.05). And through the entire canal in proximal view, there was no statistical difference in shaping percentage between both sides. But through the entire canal in clinical view, the concave side was more shaped than the convex side(P<0.1). 4. By step-back technique, the convex side at B point of clinical more shaped than the other sides(P<0.05). Through the entire canal in proximal and clinical views, there was no statistical difference in shaping percentage between both sides. 5. Comparing the total shaping percentage among techniques, that in conventional technique was the greatest numerically, and followed by the percentages in step-down/step-back, step-down/balanced force and step-back technique. But, in proximal view, shaping percentages were not statistically different among techniques(P>0.05, ANOVA test). In clinical view, shaping percentages in step-back and conventional techniques were statistically different(P<0.01, ANOVA test). * Proximal view: radiograph taken in mesiodistal direction. * Clincal view: radiograph taken in faciolingual direction. A point : 1mm point from radiographic apex B point : center point between A and C points C point : most curved point of root canal D point : center point between C point and canal oriffice.

  • PDF

Experimental Test Time Reduction Method for Step Responses Using the Time-Optimal Control Technique (시간최적제어 기법을 이용한 계단응답 실험시간 단축 방법)

  • Lee, Jietae
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.190-196
    • /
    • 2020
  • The step to obtain a process dynamic model through process experiments is very important because it needs times and expenditures. Step response method is one of the standard methods to have long been used for understanding process dynamics, obtaining dynamical models and designing control systems. For the step response, it is usually required to measure process output for a step input change in the open-loop manner. Its disadvantage criticized is the long open-loop operation. For this, a method based on the time-optimal control technique to minimize the test time for obtaining the step response has been recently presented. However, the method requires iterative computations for the minimization of test times. Here, a method where iterative computations are not required is proposed. Simulation results are presented to show that test times to obtain step responses are reduced considerably and an autotuning method based on the proposed method is compared with the relay feedback autotuning method accepted widely for the autotuning of controllers.

A Study on the Development of Physical Examination with VR Content and User Satisfaction (VR 콘텐츠를 이용한 신체검사 개발 및 사용자 만족도 연구)

  • An, Ho-Won;Kim, Jun-Min
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.318-326
    • /
    • 2021
  • This study aims to the effectiveness of physical examination using VR contents to solve problems such as the increase in chronic diseases and shortage of professional manpower in the health care field according to the aging and low birth rate, and to provide efficient healthcare. Therefore, this study implemented a one-stop VR content physical examination system by wearing HTC VIVE Pro VR and a stick controller. The system is from step 1 to step 5, and the final body age is determined and a simple solution is provided through five steps sequentially: color blind test, memory test, audiogram test, reaction speed test, and instantaneous cognitive ability test. In addition, for the one-stop VR content physical examination system developed by this study, as a result of verifying the user satisfaction for normal people who visited the health examination center and VR/AR clinical trial center of certified tertiary hospital in Daejeon, the overall satisfaction and the intention to reuse Was high, and according to gender, there was a significant difference in the 5-step test, and according to the age, there were significant differences in the 4-step test and the 5-step test.

Performance and Thermal Design Validation for FM STEP Cube Lab. (큐브위성 STEP Cube Lab. 비행 모델의 열진공시험을 통한 성능 및 열제어계 설계 검증)

  • Kang, Soo-Jin;Jung, Hyun-Mo;Seo, Joung-Ki;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.9
    • /
    • pp.814-821
    • /
    • 2015
  • The STEP Cube Lab. classified as a pico-class satellite has been successfully developed as a flight model(FM) to be launched in 2015. Its mission objective is to perform the on-orbit verification of fundamental space core-technologies. In this study, a thermal design concept based on the passive method to achieve the mission objective is introduced. The effectiveness of the thermal design and performance of the satellite has been verified through the acceptance level thermal vacuum test. In addition, to improve the reliability of thermal mathematical model, correlation was performed using the results of thermal balance test. This paper describes a series of process for the thermal vacuum test on the STEP Cube Lab. FM.