• 제목/요약/키워드: steel fiber reinforced high-strength concrete

검색결과 320건 처리시간 0.027초

대각 보강된 HPFRCCs 커플링 보의 전단강도 및 설계 (Shear Strength and Design of HPFRCCs Coupling Beam with Diagonal Reinforcement)

  • 박완신;윤현도;김선우;전에스더;김용철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.257-260
    • /
    • 2006
  • Coupled shear walls consist of two or more in-plane walls inter-connected with coupling beams. In order to effectively resist seismic loads, coupling beams must be sufficiently stiff, strong and posses a stable load-deflection hysteretic response. Much of requirements to the civil and building structures have recently been changed in accordance with the social and economic progress. Ductility of high performance fiber reinforced cementitious composites(HPFRCCs), which exhibit strain hardening and multiple crackling characteristics under the uniaxial tensile stress is drastically improved. This paper provides background for design guidelines that include a design model to calculate the shear strength of pseudo strain hardening cementitious composite steel coupling beam.

  • PDF

모어써클을 활용한 탄소섬유 전단보강된 보의 전단거동 평가 (Evaluation of Shear Behavior of Beams Strengthened in Shear with Carbon Fiber Reinforced Polymer with Mohr's Circle)

  • 김윤곤
    • 콘크리트학회논문집
    • /
    • 제28권5호
    • /
    • pp.527-534
    • /
    • 2016
  • CFRP의 전단강도 기여분을 평가하고, 모어서클을 이용하여 전단거동 특성을 분석하기 위해 전단철근비가 서로 다른 보에 동일한 탄소섬유 전단보강 설계한 보 실험을 수행하였다. 취성특성을 가지는 CFRP의 전단기여분을 평가하기 위해서는 CFRP의 변형률을 평가해야 한다. 각 실험결과는 모어써클(Mohr's Circle)을 활용하여 전단변형률을 주인장변형률 및 균열각도의 변화와 연계하여 비교하였다. 전단철근비가 작은 경우 탄소섬유 자체의 전단강도 기여분 뿐만 아니라 탄소섬유에 의해 콘크리트 균열의 진전을 제어하여 균열에 의한 콘크리트의 성능저하를 최소화한다. 전단철근비가 큰 경우는 전단철근비가 작을 때 보다 탄소섬유 보강효과가 크지 않았다. 따라서 보강부재의 전단성능을 결정할 때 탄소섬유의 전단강도 기여분은 전단철근과의 상호작용을 고려할 수 있는 변형적합조건에 근거하여 평가되어야 한다.

인발성형된 이형 GFRP 보강근과 GFRP 보강 콘크리트 부재의 크리프 거동 (Creep Behavior of Pultruded Ribbed GFRP Rebar and GFRP Reinforced Concrete Member)

  • 유영준;박영환;김형열;최진원;김장호
    • 콘크리트학회논문집
    • /
    • 제25권2호
    • /
    • pp.187-194
    • /
    • 2013
  • 섬유복합체(FRP)는 비부식성 재료라는 특징으로 인해 이상적인 철근 대체재로 주목 받고 있다. 그러나 현재 FRP 보강근은 철근과 달리 일반적으로 수용되는 고정된 형태가 존재하지 않고 다양한 재료와 성분비, 형태 등으로 제작되기 때문에 이에 대한 성능평가 데이터에 근거한 FRP 보강 콘크리트 부재의 거동특성 구명은 상당부분 제한될 수 있다. 더군다나 FRP 보강 콘크리트 부재의 휨거동에 대한 평가는 주로 단기 거동 측면에 집중되어 이루어져 왔다. 이 연구는 GFRP 보강근 및 이를 사용하여 보강된 콘크리트 부재의 장기거동을 평가하기 위한 것으로, 먼저 철근 대체용으로 개발된 GFRP 보강근에 대한 성능평가 결과를 제시하였고, 이의 크리프 거동 특성에 대한 3년간의 계측 결과를 제시하였다. 실험 결과 인장강도의 약 55% 이하의 하중이 지속적으로 재하되는 경우에는 100년 이상의 내구연한을 확보할 수 있는 것으로 나타났다. 또한 GFRP 보강 콘크리트 보의 장기거동을 약 1년간 관찰하였으며 이로부터 FRP 보강 부재의 장기처짐 계산식에 사용되는 수정계수 값 0.73을 도출하였다. 따라서 이 연구로부터 도출된 GFRP 보강근 및 이로 보강된 콘크리트 보의 단기 및 장기 거동 특성값은 FRP 보강 콘크리트 부재의 설계에 유용하게 활용될 수 있을 것으로 사료된다.

초고강도 콘크리트를 활용한 고온가열 이후의 탄소 보강근과 철근의 잔류 부착성능 평가 (Evaluation of Residual Bond Stress between Carbon-fiber Reinforced Polymer and Steel Rebar Using Ultra-High-Performance-Concrete after Elevated Temperature)

  • 유선재;이호진;원천봉;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.169-176
    • /
    • 2021
  • 본 연구에서는 고온가열 이후의 탄소 보강근의 잔류 부착 강도 평가를 위하여 상온, 150℃에 따른 부착실험을 수행하였으며, 탄소 보강근과의 비교를 위한 D10 및 D13 철근도 고온 가열한 이후 잔류 부착 강도를 평가하였다. 실험 결과, 150℃ 가열 이후 탄소 보강근의 부착 강도는 상온 대비 약 9.94% 감소하였다. 반면 가열 이후 D10 철근 및 D13 철근 모두 탄소 보강근 대비 부착 강도 감소율이 적게 나타났다. 또한 온도 가열 이후 최대부착 강도에서 발생한 슬립도 탄소 보강근과 철근 모두 줄어드는 경향을 보였다. 이를 통해 고온가열에 따른 부착 강도와 슬립 감소의 상관관계를 확인하였으며, 부착-슬립 곡선을 나타내었다. 최종적으로는 실험 결괏값을 상대부착 강도로 나타냄으로써 가열 이후 탄소 보강근 및 철근의 잔류 부착성능을 확인하고자 하였다.

고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구(1) (An Experimental Study on the Flexural Behavior of RC Beams Strengthened with High-Strength Bars(1))

  • 신경재;곽명근;허병욱;나정민;오영석
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.527-534
    • /
    • 2006
  • 본 논문은 외부 비부착 고장력 인장봉을 사용한 새로운 방식의 RC보의 휨보강공법에 관한 논문이다. 제안된 공법의 장점은 기존의 보강방식과 비교하여 빠르고 간단하게 시공할 수 있다는 점이다. 제안된 공법은 기존의 외부 비부착 프리스트레스 텐던공법의 많은 장점을 보유함과 동시에 프리스트레싱 작업시간을 단축시킨 공법이다. 탄소섬유쉬트, 강판 및 고장력 인장봉과 같은 서로 다른 보강재를 사용하여 보강한 철근콘크리트보 실험체를 총 9개 제작하여 실험하였다. 실험 결과, 탄소섬유쉬트로 보강된 RC보는 쉬트의 박리로 인한 취성파괴모드를 나타내었다. 강판보강 시험체의 경우도 기존의 일반적인 앵커와 에폭시로 접합을 할 경우에 강판보강의 효과가 떨어지고 앵커설계를 특별히 하고 시공에 유의하여야 함을 보여주고 있다. 반면에 고장력 인장봉을 사용한 RC보의 경우에는 무보강 RC보와 비교하여 최대내력이 212% 증가하였고, 중앙부 처짐은 65% 감소되었다. 실험 결과는 고장력 인장봉으로 보강된 RC보는 특히 강도와 변형능력에서 기존의 보강방법을 사용한 실험체보다 우수성을 보여주었다.

고품질 숏크리트 개발을 위한 새로운 급결제 적용 (Application of New Type Accelerator for High Quality Shotcrete)

  • 박해균;이명섭;김재권;정명근
    • 한국터널지하공간학회 논문집
    • /
    • 제4권1호
    • /
    • pp.45-55
    • /
    • 2002
  • 1980년 초 서울지하철 건설공사를 계기로 국내의 터널공사에 NATM(New Austrian Tunnelling Method)공법이 적용되고 있다. 하지만, 주지보재의 하나인 숏크리트 기술은 NATM공법이 국내에 들어온 초기의 기술력을 아직 답습하고 있는 상태로 다량의 리바운드가 발생하고, 노즐맨의 경험이나 기량등에 의존하는 경우가 많아 비용절감 및 시공능률 향상을 위한 개선이 절실히 요구되고 있는 실정이다. 본 논문에서는 숏크리트 품질확보에 중요한 위치를 차지하고 있는 급결제(Accelerator)를 주변수로 강섬유보강 숏크리트(SFRS)에 대한 모형시험을 실시하여 고품질 숏크리트에의 적용 가능성을 검토하였다. 모형시험(압축강도, 휨강도, 휨인성)결과, Alkali-free 액상급결제를 사용한 숏크리트를 통해 고강도 발현을 위한 고가의 혼화재를 사용하지 않고서도 고품질의 고강도 숏크리트 개발 가능성을 확인할 수 있었으며, Single-Shell Lining 터널 등 Permanent Shotcrete Lining이라는 새로운 개념의 터널 지보시스템 구축을 위한 요소기술로 그 적용이 확대될 것으로 판단된다.

  • PDF

Low velocity impact behavior of concrete beam strengthened with CFRP strip

  • Kantar, Erkan;Anil, Ozgur
    • Steel and Composite Structures
    • /
    • 제12권3호
    • /
    • pp.207-230
    • /
    • 2012
  • Nowadays CFRP (Carbon Fiber Reinforced Polymer) became widely used materials for the strengthening and retrofitting of structures. Many experimental and analytical studies are encountered at literature about strengthening beams by using this kind of materials against static loads and cyclic loads such as earthquake or wind loading for investigating their behavior. But authors did not found any study about strengthening of RC beams by using CFRP against low velocity impact and investigating their behavior. For these reasons an experimental study is conducted on totally ten strengthened RC beams. Impact loading is applied on to specimens by using an impact loading system that is designed by authors. Investigated parameters were concrete compression strength and drop height. Two different sets of specimens with different concrete compression strength tested under the impact loading that are applied by dropping constant weight hammer from five different heights. The acceleration arises from the impact loading is measured against time. The change of velocity, displacement and energy are calculated for all specimens. The failure modes of the specimens with normal and high concrete compression strength are observed under the loading of constant weight impact hammer that are dropped from different heights. Impact behaviors of beams are positively affected from the strengthening with CFRP. Measured accelerations, the number of drops up to failure and dissipated energy are increased. Finite element analysis that are made by using ABAQUS software is used for the simulation of experiments, and model gave compatible results with experiments.

Compressive behavior of galvanized steel wire mesh (GSWM) strengthened RC short column of varying shapes

  • Marthong, Comingstarful
    • Structural Monitoring and Maintenance
    • /
    • 제7권3호
    • /
    • pp.215-231
    • /
    • 2020
  • In a reinforced concrete building different shapes of column are adopted depending on the structural orientation and the architectural aspect. When there is an increase in loading due to changes in usage or revision in the design codes these columns need to be strengthened for enhanced performance during their service life. Strengthening materials such as carbon fiber and glass fiber polymer has been successfully used however, due to high cost application other alternative materials need to be explore. Galvanized steel wire mesh (GSWM) is one of the suitable materials locally available. High tensile strength, low weight, corrosion resistance, easy installation, minimum change in dimensions of the sections and cost effectives are the advantages of GSWM. Therefore, in this paper, four different shapes of column such as circular, square, rectangular and L were wrapped with different layers GSWM and jacketed with mortar. All the specimens were tested under axial compression. The objective of the study is to investigate the effectiveness of GSWM as a confining material for strengthening of column having varying shape. Test results shows that the axial strength enhanced with wrapping of GSWM jacket and a circular column presented the highest load carrying capacity and ductility as compared to the others. From the study of 22 column specimens, it is found that axial load is increased upto 20% and 19% when circular and square column are strengthened with one wrap of GSWM respectively, while a rectangular and L column required a wraps of two and three layers respectively in order to achieved the same load capacity as that of a circular column. Based on the present study, it is concluded that GSWM can be effectively used for strengthening of different shapes of concrete columns economically.

GFRP 보강근으로 보강된 교량 바닥판의 성능과 사용성에 관한 실험연구 (Service and Ultimate Load Behavior of Bridge Deck Reinforced with GFRP Rebars)

  • 유영준;박영환;박지선
    • 대한토목학회논문집
    • /
    • 제28권5A호
    • /
    • pp.719-727
    • /
    • 2008
  • GFRP 보강근의 인장강도 및 부착성능 등은 철근과 다르기 때문에 GFRP 보강근을 콘크리트 구조물에 적용하기 위해서는 GFRP 보강근으로 보강된 콘크리트 부재의 거동에 관한 연구가 선행되어야 한다. GFRP는 높은 비강도, 경량성, 비부식성 등의 장점을 가지고 있으나 탄성계수가 철근보다 작아 상대적으로 큰 처짐이 발생하는 단점이 있다. 교량 바닥판은 아칭효과 등에 의해 휨성능이 증가하므로 FRP 보강근을 우선 적용할 수 있는 대상 중 하나이다. 본 논문은 국내에서 개발된 철근 대체재용 GFRP 보강근의 콘크리트 구조물로의 적용 가능성을 관찰하기 위한 실험연구에 관한 것이다. 대상 실험체는 폭과 길이가 3,000 mm, 4,000 mm이고 두께가 240 mm인 실제 크기의 콘크리트 바닥판이다. 실험변수는 보강근 종류(철근, GFRP 보강근)와 보강비로 총 3개의 바닥판을 제작하였다. 정적실험을 수행하였으며 DB-24 하중등급의 축하중을 모사한 재하면적을 가진 직사각형 강재로 바닥판이 파괴될 때까지 집중하중을 가하였다. 철근 보강 바닥판과 GFRP 보강 바닥판의 거동차이를 최대성능, 처짐 및 균열 거동 등에 대해 비교 검토하였다.

GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가 (Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio)

  • 유영준;박영환;최지훈;김장호
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.491-497
    • /
    • 2014
  • 철근의 부식은 철근콘크리트 교량 바닥판의 성능 저하에 큰 요인으로 작용한다. FRP는 비부식성 재료이기 때문에 이를 활용하여 보강근을 개발하려는 노력이 이루어지고 있다. 여러 종류의 FRP 보강근이 개발되었으나 아직 활용 실적은 많지 않은 상황이다. 그 이유로는 FRP 보강 콘크리트 구조물에 대한 단/장기 검증 데이터가 부족하기 때문이다. 이 연구에서는 GFRP 보강 바닥판에 대한 피로성능을 관찰하기 위해서 길이 4000 mm, 폭이 3000 mm, 높이 240 mm인 실제 크기의 교량 바닥판을 도로교설계기준을 준용하여 제작한 후 실험을 실시하였다. 하부 보강비를 변수로 설정하였으며 DB-24 하중이 바닥판 중앙에 집중 작용하는 것으로 실험을 실시하였다. 사용하중의 3.5, 4.5, 5.0배에 해당하는 다양한 하중을 2백 만회 이상 반복 재하하여 GFRP 보강 바닥판의 피로성능을 관찰하였다. 실험 결과 거더가 횡구속된 GFRP 보강 바닥판의 최대성능은 보강근비에는 민감하지 않았고, 피로성능은 보강비보다는 적용하중의 크기에 민감하며, 바닥판이 200만회 이상 반복재하에 저항하기 위해서는 재하되는 집중하중의 크기는 최대하중의 58% 수준 이하이어야 하며, 이 연구의 실험 대상 GFRP 보강 바닥판의 피로수명은 철근 콘크리트 바닥판의 수명 예측값보다는 다소 낮은 값을 나타내었고 FRP 보강 콘크리트 바닥판의 기존 예측값보다는 높은 값을 나타내었다.