• 제목/요약/키워드: static horizontal load

검색결과 103건 처리시간 0.026초

건식 경량벽체의 구조안전성에 영향을 미치는 수평하중의 종류 및 특성 고찰 (A Review of the Types and Characteristics of Horizontal Load Affecting the Structural Safety of the Lightweight Dry Walls)

  • 송정현;노용운;김기준;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.43-45
    • /
    • 2013
  • The purpose of this study is to obtain basic data for making performance criteria about the structural safety of lightweight dry wall later by examining types and characteristics of horizontal load acting on the wall. The subjects applying horizontal load to the wall are human and objects. The types of horizontal load are classified as static load and dynamic load depending on the difference of acting time. The magnitude of horizontal load "0.25kN/㎡" defined by KBC 2009 has no significant meaning since it is the unsubstantial nominal load. The result of examining types and characteristics of horizontal load is as follows. (1) Static load by human needs to have more systematic investigation including differences in wall hardness and human weight. (2) Dynamic load by human needs to raise the significance of study result by increasing the number of subjects. (3) Dynamic load by objects needs to accumulate the load specific data for various load subjects considering real situations.

  • PDF

정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구 (Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load)

  • 송정현;김기준;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

경량벽체에 작용하는 인간에 의한 정적하중의 특성 (Characteristic of Human Static load Acting on the Lightweight Wall)

  • 송정현;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.192-193
    • /
    • 2013
  • The purpose of this research is to comprehend experimentally the nature of human static load to wall for making use of the result as basic data to evaluate resisting force of lightweight wall. Human motions exerting static load are classified to 4 types, and two-hands pushing and shoulder pushing are defined as the instantaneously forcing motions with hands or shoulder put on the load plate, respectively. Back leaning and one-hand leaning are defined as motions of taking a rest in their respective comfortable posture. Measurement of static horizontal load caused by each motion showed that the highest load ratio depends on hardness of load plane and was 1.17~1.25 times of weight in two-hands pushing, 0.95~0.99 times in shoulder pushing, 0.16~0.18 times in back leaning, and 0.12~0.15 times in one-hand leaning.

  • PDF

CFRP strengthening of steel beam curved in plan

  • Keykha, Amir Hamzeh
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.637-648
    • /
    • 2021
  • Nowadays, one of the practical, fast and easy ways to strengthen steel elements is the use of Carbon Fiber Reinforced Polymer (CFRP). Most previous research in the CFRP strengthening of steel members has carried out on straight steel members. The main difference between horizontal curved beams and straight beams under vertical load is the presence of torsional moment in the horizontal curved beams. In the other words, the horizontal curved beams are analyzed and designed for simultaneous internal forces included bending moment, torsional moment, and shear force. The horizontal curved steel beams are usually used in buildings, bridges, trusses, and others. This study explored the effect of the CFRP strengthening on the behavior of the horizontal curved square hollow section (SHS) steel beams. Four specimens were analyzed, one non-strengthened curved steel beam as a control column and three horizontal curved steel beams strengthened using CFRP sheets (under concentrated load and uniform distributed load). To analyze the horizontal curved steel beams, three dimensional (3D) modeling and nonlinear static analysis methods using ANSYS software were applied. The results indicated that application of CFRP sheets in some specific locations of the horizontal curved steel beams could increase the ultimate capacity of these beams, significantly. Also, the results indicated when the horizontal curved steel beams were under distributed load, the increase rate in the ultimate capacity was more than in the case when these beams were under concentrated load.

정하중 및 동하중이 작용하는 연약지반의 거동특성(비교모형실험) (Characteristic of a Soft Ground Behavior Subjected to Static and Dynamic Loads (A Study on the Model Test))

  • 김종렬;강진태;이치열;박용면;정재훈
    • 한국지반공학회논문집
    • /
    • 제24권1호
    • /
    • pp.111-118
    • /
    • 2008
  • 본 연구에서 준설매립지반과 같은 연약지반의 개량 시 장비의 연행하중이 지반에 미치는 영향을 파악하고자 2차원 모형재하시험을 실시하였다. 정하중 및 동하중은 각각 $0.02kg/cm^2,\;0.03kg/cm^2$$0.04kg/cm^2$으로 압밀된 모형지반에 재하하였다. 압밀하중 $0.02kg/cm^2,\;0.03kg/cm^2$$0.04kg/cm^2$으로 2달간 압밀시킨 후 각각의 압밀하중으로 인한 극한지 지력은 $0.16kg/cm^2,\;0.19kg/cm^2,\;0.24kg/cm^2$인 것을 얻을 수 있었다. 그리고 정하중시험의 침하량과 같아지는 지점의 동하중시험 시 에너지 값은 각각의 압밀하중에 대하여 $E=336{\sim}945kg{\cdot}cm,\;E=252{\sim}780kg{\cdot}cm$$E=323{\sim}727kg{\cdot}cm$의 범위를 나타냈다. 같은 지반조건에서 정하중과 동하중이 각각 작용할 경우, Heaving량은 정하중보다 동하중 작용시 더 컸으며, 수평변위량은 정하중 시험에 비해 극히 미비하게 나타났다.

PAR에 의한 강관 말뚝의 극한 수직 및 수평 지지력 예측 (Prediction on Ultimate Vertical and Horizontal Bearing Capacity of Steel Pipe Piles by Means of PAR)

  • 최용규
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.13-24
    • /
    • 1997
  • 말뚝 해석 프로그램인 PAR에 의하여 말뚝의 극한 수직 및 수평 지지력을 예측할 수 있는 방법을 제안하였으며,현장에서 수행된 말뚝재하시험 결과들을 이용하여 PAR에 의한 사례연구를 수행하였다. PAR에 의해 해석된 말뚝의 극한지지력은 정재하시험에서 구한 지지력에 대하여 약 15%이내의 오차범위에 들었다. 또한, 강관말뚝들에 수행된 정재하시헙, 정.동재하시험 그리고 PDA 결과들을 비교하였으며, PAR에 의해 극한지지력을 예측하였다. PAR을 이용하면 말뚝의 축방향 하중의 분포를 예측할 수 있었으며, 여기서, 하중전이해석도 근사적으로 수행할 수 있었다.

  • PDF

Investigation on the failure type of tower segments under equivalent static wind loads

  • Li, Yue;Xie, Qiang;Yang, Zheng
    • Wind and Structures
    • /
    • 제34권2호
    • /
    • pp.161-171
    • /
    • 2022
  • This paper presents a failure type assessment curve method to judge the failure type of transmission tower segments. This novel method considers the equivalent static wind load characteristics and the transmission tower members' load-bearing capacities based on numerical simulations. This method can help judge the failure types according to the relative positions between the actual state points and the assessment curves of transmission tower segments. If the extended line of the actual state point intersects with the horizontal part's assessment curve, the segment would lose load-bearing capacity due to the diagonal members' failure. Another scenario occurs when the intersection point is in the oblique part, indicating that the broken main members have caused the tower segment to fail. The proposed method is verified by practical engineering case studies and static tests on the scaled tower segments.

면진장치 설치각도에 따른 아치구조물의 지진응답 (Seismic Response of Arch Structure with Base Isolation Device Depending on Installation Angle)

  • 김기철;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권1호
    • /
    • pp.25-32
    • /
    • 2022
  • The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.

Frictional responses of concrete-to-concrete bedding planes under complex loading conditions

  • Dang, Wengang;Konietzky, Heinz;Li, Xiang
    • Geomechanics and Engineering
    • /
    • 제17권3호
    • /
    • pp.253-259
    • /
    • 2019
  • Concrete-to-concrete bedding planes (CCBP) are observed from time to time due to the multistep hardening process of the concrete materials. In this paper, a series of direct/cyclic shear tests are performed on CCBP under static and dynamic normal load conditions to study the frictional behavior effect by the shear velocities, normal impact frequencies, horizontal shear frequencies, normal impact force amplitudes, horizontal shear displacement amplitudes and normal load levels. According to the experimental results, apparent friction coefficient k ($k=F_{Shear}/F_{Normal}$) shows different patterns under static and dynamic load conditions at the stable shear stage. k is nearly constant in direct shear tests under constant normal load conditions (DCNL), while it is cyclically changing with nearly constant peak value and valley value for the direct shear tests under dynamic normal load conditions (DDNL), where k increases with decreasing normal force and decreases with increasing normal force. Shear velocity has little influence on peak values of k for the DCNL tests, but increasing shear velocity leads to increasing valley values of k for DDNL tests. It is also found that, the valley values of k ascend with decreasing impact normal force amplitude in DDNL tests. The changing pattern of k for the cyclic shear tests under constant and dynamic normal load conditions (CCNL and CDNL tests) are similar, but the peak value of k is smaller in CDNL tests than that in CCNL tests. Normal load levels, shear displacement amplitudes, vertical impact frequencies, horizontal shear frequencies and normal impact force amplitudes have little influence on the changing pattern of k for the cyclic shear tests. The tests of this study provide useful data in understanding the frictional behavior of the CCBP under distinct loadings, and these findings are very important for analyzing the stability of the jointed geotechnical structures under complicated in situ stress conditions.

철도교량용 고무패드의 특성 및 강성 추정기법 (The Characteristics and Estimated Stiffness of Rubber Pads for Railway Bridges)

  • 최은수;김현민;오지택;김성일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.115-122
    • /
    • 2005
  • This study analyzed the characteristics of four kinds of bridge rubber pads and suggested how to determine the stiffness the pads. The stiffness of rubber pads can be estimated by a direct static test. In the procedure to estimate the stiffness of a pad, the dead load(preload) of a bridge and live load of a vehicle are considered. The polyurethane rubber pads have larger hardness than natural and chloroprene rubber pads and thus carry larger load bearing capacity. In addition, they showed higher stiffness with the same shape factor than the others and thus are more avaliable as for bridge bearings. Although natural and chloroprene rubber pads are elongated to large deformation in horizontal direction due to vertical loads, polyurethane rubber pads almost do not generate horizontal deformation due to vertical loads regardless to the thickness and hardness of the pads. Therefore, they do not need reinforced plate to restrict horizontal deformation.

  • PDF