• Title/Summary/Keyword: static design

Search Result 3,384, Processing Time 0.031 seconds

Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level (비소음 측정을 이용한 저소음 축류홴 설계)

  • 김창준;이동익
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF

Strength Design of Driveshafts for Passenger Cars (승용차용 구동축의 강도설계)

  • Jeong, Chang-Hyun;Jung, Do-Hyun;Bae, Won-Rak;Kim, Jin-Yong;Im, Jong-Soon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.114-123
    • /
    • 2007
  • We are going to propose equations for stable static and endurance strength design of driveshafts. It is very important to decide the contact normal stress of internal components of CV joints. We can estimate the strength, torque capacity, endurance life of CV joints from contact normal stress by presented equation in this paper. Besides it can be shown the equation for shaft design.

IDDQ Testable Design of Static CMOS PLAs with tow rower Consumption

  • Hoshika, Hiroshi;Hashizume, Masaki;Yotsuyanagi, Hiroyuki;Tamesada, Takeomi
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.351-354
    • /
    • 2000
  • In the past, we proposed an IDDQ testable design method for static CMOS PLA circuits. All bridging faults can be detected in NOR planes of our testable designed PLA circuits by IDDQ testing with 4 kinds of test input vectors which are independent of the logical functions to be realized. However, the testable designed PLA circuits consume large power in the normal operation. In this paper, a new IDDQ testable design method is proposed and evaluated by some experiments. The experimental results show that the PLA circuit designed with our method can work with low power consumption than the previous one.

  • PDF

전기체 정적시험 치구설계 기술보고서

  • Kim, Sung-Chan;Shin, Jeong-Woo;Shim, Jae-Yeul;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.32-44
    • /
    • 2002
  • This paper contains the information that describes the test fixture design and technology for full-scale airframe static test. Obtained technologies consist of determination of design load for test fixture, design technique for loading system, counterbalance system, positioning system of test article, test equipment and overload protection method. Full-scale airframe static test of advanced jet trainer was implemented using test fixture which are applied these technique.

  • PDF

Design of Passive Parameters for A Cascade Multilevel Inverter Based Static Var Compensator (직렬형 멀티레벨 인버터를 사용한 무효전력보상장치의 수동 파라메타 설계)

  • Min, Wan-Ki;Min, Jun-Ki;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.125-130
    • /
    • 2002
  • This paper examines the application of high voltage static var compensator(SVC) with cascade multilevel inverter which employs H~bridge inverter(HBI). The SVC system is modeled using the d-q transform which calculates the instantaneous reactive power. This model is used to design a controller and analyze the SVC system. From the mathematical model of the system, the design procedures of the circuit parameters Land C are presented in this thesis. To meet the specific total harmonic distortion(THD) and ripple factor of the capacitor voltage, the circuit parameters Land C are designed. Simulated and experimental results are also presented and discussed to validate the proposed schemes.

  • PDF

Numerical Analysis for the Flow Uniformity in the LP-SCR Reactor (LP SCR 반응기 내 유동 균일도 개선을 위한 해석적 연구)

  • Um, Hyung Sik;Kim, Gun Ho;Kim, Dae Hee;Kim, Kyu Jong;Kim, Jung Rae
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.61-63
    • /
    • 2015
  • In the low pressure selective catalytic reduction (LP SCR) system, the uniformity of both ammonia concentration and exhaust gas flow at the SCR catalyst layer are important design factor for the efficient SCR-deNOx performance. According to the shape of the guide vane and static mixer, numerical simulations were conducted to analyze flow patterns and finally to find out the appropriate alternative for uniform flow at the front of catalyst in the real scale LP SCR reactor. The variations of gas velocity and ammonia concentration were quantitatively evaluated. Based on the present results, the shape was devised to satisfy the design criteria.

  • PDF

Impact Analysis of Seismic Load on the Design of Turbine-Generator Foundations (지진하중이 터빈-발전기 기초의 설계에 미치는 영향)

  • 김재석;조양회;안대호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.224-231
    • /
    • 2003
  • The purpose of this study is to review and validate the seismic analysis procedures of turbine-generator foundation specified in the Korea Building Code which adopts equivalent static analysis. Typical machines and foundations were chosen and various kinds of parametric studies were peformed and the results were compared with the detail dynamic analysis. The general trend of the study results showed that the most of the computed responses of equivalent static analysis are smaller than those of the dynamic analyses(response spectrum analysis and time history analysis), which implies the existing seismic analysis technique using the existing Building Code may give unconservative design results. The results also showed that the seismic loads are one of the governing design parameters of the turbine-generator foundations.

  • PDF

Modal rigidity center: it's use for assessing elastic torsion in asymmetric buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • v.1 no.2
    • /
    • pp.163-175
    • /
    • 2010
  • The vertical axis through the modal center of rigidity (m-CR) is used for interpreting the code torsional provisions in the design of eccentric multi-story building structures. The concept of m-CR has been demonstrated by the author in an earlier paper and the particular feature of this point is that when the vertical line of the centers of mass at the floor levels is passing through m-CR, minimum base torsion is developed. For this reason the aforesaid axis is used as reference axis for implementing the code provisions required by the equivalent static analysis. The study examines uniform mixed-bent-type multistory buildings with simple eccentricity, ranging from torsionally stiff to torsionally flexible systems. Using the results of a dynamic response spectrum analysis as a basis for comparisons, it is shown that the results of the code static design are on the safe side in torsionally stiff buildings, but unable to predict the required strength of bents on the stiff side of systems with a predominantly torsional response. Suggestions are made for improving the code provisions in such cases.

Reliability Verification of Numerical Prediction Method on Pile Behaviour Characteristics using Field Static Loading Test (현장정재하시험을 이용한 말뚝 거동특성 수치해석 예측기법의 신뢰성 검증)

  • Nam, Hosung;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.9
    • /
    • pp.11-18
    • /
    • 2017
  • Numerical analysis method for prediction of pile behaviour characteristics has widely been used in detail design process before construction because field static loading test requires high cost. However, the reliability verification of numerical analysis of result is not permitted compare with field test. In this study, to verify the numerical analysis results, pile behaviour prediction was compared with field static loading test results. For exact analysis of interaction between pile and ground, soil investigation and in-situ test such as boring, SPT and bore-hole shear test were performed before pile static loading test. During the static loading test, pile behaviour characteristics were analyzed under every loading condition. After static pile loading test, numerical analysis was carried out under same condition with static pile loading test. In the numerical analysis, to apply same loading condition with each loading condition in the field test and to compare with between the results of numerical analysis, the field test results for reliability were verified with the results of numerical analysis.

The Effect of Therapeutic Ultrasound and Static Stretching of the Hamstring Muscle on Flexibility and Static Balance Ability (초음파 치료와 정적 스트레칭이 뒤넙다리근의 유연성과 정적균형에 미치는 영향)

  • Cho, Seung-bong;Park, Mi-young;Won, Ji-sun;Kim, Ye-lin;Hong, Joon-taek;Kim, Seong-ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • Background: The purpose of present study was to examine the effect of ultrasound therapy and static stretching on hamstring length and balance. Design: Randomized Controlled Trial. Methods: A total of 30 adults in S college, Seongnam city, Gyeonggi-do, between the ages of 20-30 were randomly assigned to two groups. Group 1 (n=15) had ultrasound therapy, called US group. Group 2 (n=15) had static stretching, called SS group. Measurements were taken prior to starting the program and after completing the experiment using Finger to floor test and Active knee extension test to get the results of hamstring flexibility and the ability of static balance. Paired t-test was used to compare each group pre-test values to post-test values and to compare US post-test values to SS post-test values on PASW 18.0. Results: 1) Both hamstring SS group and US group had significant increase (p<.05) in Finger to floor test and Active knee extension test. 2) Dominant leg standing had significant change (p<.05) only in US group. 3) There was no significant difference between US group and SS group. Conclusion: Results showed that US group and SS group had an effect on changes in hamstring length (p<.05). However, they did not show a significant increase in static balance. Further effective studies on hamstring SS group and US group were needed based on this examination.