• Title/Summary/Keyword: statement analysis

Search Result 594, Processing Time 0.027 seconds

The Effect of $OPB-K^{(R)}$ on the Osseointegration and Stability of Implant ($OPB-K^{(R)}$가 임플랜트의 골유착 및 안정성에 미치는 영향에 관한 연구)

  • Kang, Sung-Jin;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.31-41
    • /
    • 2008
  • Statement of problem: It has been proved that Pleurotus eryngii Quel and Eleutherococcus senticosus have antiinflammatory action and not only stimulates the proliferation and activity of osteoblast but inhibits the generation and activity of osteoclast in vitro. Pleurotus eryngii Quel and Eleutherococcus senticosus are the main component of $OPB-K^{(R)}$. Purpose: The purpose of this study was to evaluate $OPB-K^{(R)}$ which enhances the healing rate of peri-implant bone and the bone mineral density. Materials and methods: Thirty six specially designed implants were installed in the tibia of rats. The group medicated with $OPB-K^{(R)}$ was the experimental group, and that without was the control group. hen the implant stability was measured by $Periotest^{(R)}$. Bone mineral density and histological measurement were conducted at the 2nd, 4th and 6th week $Periotest^{(R)}$ and bone mineral density values were analyzed statistically with independent t-test at 95% confidence level(p<0.05). Results: The results of this study were as follows : 1. There was no statistically significant difference in $Periotest^{(R)}$. values between the experimental group and control group at the 2nd week, however, on the 4th and 6th week there was significant difference(p<0.05). 2. There was no statistically significant difference in bone mineral density between the experimental group and control group at the 2nd and 4th week, however on the 6th week there was significant difference(p<0.05). 3. Histological analysis showed difference in osseointegration on the 4th and 6th week between the groups. Conclusion: From the results, it is concluded that the $OPB-K^{(R)}$ medicated group showed statistically better results in bone density and stability than the control group. Clinically it would be better to medicate $OPB-K^{(R)}$ to patients for a long period of time after implantation to get superior results.

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

A retrospective statistical analysis of dental implants (치과 임플란트 환자의 통계 분석에 관한 후향적 연구)

  • Zhao, Chun-Ri;Cho, In-Ho;Moon, Eun-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.266-272
    • /
    • 2009
  • Statement of problem: The number of edentulous patients is increasing due to an aging society, which leads to increased demands and interests on implant restorations. Implant restorations are an effective treatment method for both complete and partially edentulous patients, and the success rate has been reported to be high. But because of the increased use of implants in various situations have resulted in frequent reports of failures on implant restorations. Various efforts to overcome these failures have been made. Purpose: The aim of this study was to investigate the statistic survival rate of dental implants on patients who were treated at Dankook University Dental Hospital during the past 10 years based on their charts. Materials and methods :The research was made for two different periods of time; The first investigation was for patients from August, 1998 to August, 2003 and the second was for patients from September, 2003 to April, 2007. Information on the number of implants placed, the location and distribution of implants, the duration between the first and second surgery, and the survival rate of implants were investigated from the patients'charts. Results: 1. According to the first investigation, 1680 implants were placed on 612 patients and the second investigation showed 2438 implants placed on 933 patients. Thus a total of 4118 implants on 1545 patients. 2. Among the 1545 patients, 884 patients were male (57.2 %) and 661 patients were female (42.8%). Out of 4118 implants, 1739 implants (42.2%) were placed on the maxilla, and 2379 implants (57.8%) on the mandible. Implants were placed most frequently in the posterior region of the mandible. A total of 2043 implants (53.2%) were placed in this region. 3. According to the first investigation, 57 out of 1680, implants failed, while from the second investigation, 17 out of 2438 implants were reported as failure. In total, 74 implants failed, which results in a 98.2% survival rate. 4. The average duration between the first and the second surgeries in maxillas decreased from 7.4 months to 6.8 months. The duration also decreased from 5.6 months to 5.0 months in mandibles. Conclusion: As shown in the results, the number of placed implants and the survival rate of implants were higher in the second investigation than that of the first investigation. And the time spent after the first surgery to the second surgery was less in the second investigation. Consequently, it can be presumed that the demand and consumption of dental implants as well as the survival rate will increase in the future.

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

The Effect of Three Surface Sealants on Microleakage of Class V Composite Resin Restorations (복합레진으로 수복한 5급 와동의 미세누출에 대한 3종의 레진 표면 전색제의 효과)

  • Lee, Won-Cheol;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.182-190
    • /
    • 2009
  • Statement of problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration. Purpose: The aim of this study was to assess the effectiveness of three different surface sealants(Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250). Material and methods: Forty noncarious human premolars and molars extracted within a three-month period were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test($\alpha$=0.05). Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group(P<.05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin(P>.05). Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study (두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study))

  • Lee, Ji-Eun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Han, Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.169-174
    • /
    • 2008
  • Statement of problem: Changes of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. It was proposed that bone-retention elements such as microthreads at the coronal part of implant might help maintain the marginal bone level. Purpose: This study was designed to evaluate the effect of microthread configuration within the marginal coronal portion of the implant fixture at the marginal bone changes after loading around two different external hex implants. Material and methods: Twenty-four patients were included and randomly assigned to treatment with $Br{{\aa}}nemark$ system implants (Group 1, rough-surfaced implants, n=20) and Oneplant system implants (Group 2, rough-surfaced neck with microthreads, n=20). Clinical and radiographic examinations were conducted at baseline (implant loading) and 1 year postloading. Data analysis was performed by the SAS statistical package version 9.1.3 (SAS Institute, Cary, NC, USA) and the final model was calculated by the MIXED procedure (three-level ANCOVA) for marginal bone change of each test group at baseline and 1 year follow-up. Results: Comparing to baseline, significant differences were noted in marginal bone level changes for the 2 groups at 1 year follow-up (P<0.05). Group 1 had a mean crestal bone level changes of $0.83{\pm}0.31mm$; Group 2 had a mean crestal bone level changes of $0.44{\pm}0.36mm$. Rough-surfaced with microthreads implants showed significantly less marginal bone loss than rough surfaced neck without microthread implants. Conclusion: A rough surface with microthreads at the implant was beneficial design to maintain the marginal bone level against functional loading.

An Analysis of the Cognition of Professionals Regarding the Validity of Planting Design Change that Occurred in the Landscape Construction of a Major Private Company (민간기업 조경공사에서 나타나는 식재설계 변경 타당성에 대한 전문가 인식 분석)

  • Park, Jae-Young;Cho, Se-Hwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.101-110
    • /
    • 2014
  • This study analyzes the validity of the type classification of the type and design changes of apartment landscaping planting construction design changes that were completed in the private sector, efficiently manages the design changes that are displayed over landscaping planting work in general in the future, and performs research by placing the object underlying the presentation. The results are as follows. First, the percentage that occurred in the planting construction of design changes that have occurred in the apartment landscaping construction was carried out in the private sector and accounted for 61.8%. This indicates that part of the planting is a major design change. Second, as the cause of such a design change to be those associated with the field conditions such as lack of main construction period. In particular, due to a change in oral, appeared 7-48 times design changes of one review design change approval is complex, design changes of planting construction had shown a feature that occurs in multiple simultaneous. Third, the 7 types of Design Changes in planting design were delineated as 'design changes for consideration of the user', 'design changes for image improvement', 'design changes for ease of maintenance', 'design changes due to the mismatch of design statement', 'design changes due to the relationship with the engineering species of other', 'design changes due to lack of field study', and 'design changes due to the consideration of feasibility.' Fourth, 'design changes for consideration of the user' and 'design changes for image improvement' were found in more than half of the frequency of the overall changes. This differed from the results shown in public corporations. Fifth, if planting construction design change process, private companies, it was found that is showing the approval of the practice after the previous construction of the construction cost savings due to construction time. However, in the case of a public corporation, these exhibited a different aspect from the private sector and show a design change procedure that reflects the changes after the design change events in the field have occurred. The above results, the type of landscaping works in planting design change of public enterprises, regardless of the private sector, is the same in the seven types, the main reason of and procedures for design changes, indicating that there are other respects. In design change, it may be desirable to apply becomes liquidity rationality and efficiency of the dimension, depending on the nature of the landscape construction.

Exploring Mask Appeal: Vertical vs. Horizontal Fold Flat Masks Using Eye-Tracking (마스크 매력 탐구: 아이트래킹을 활용한 수직 접이형 대 수평 접이형 마스크 비교 분석)

  • Junsik Lee;Nan-Hee Jeong;Ji-Chan Yun;Do-Hyung Park;Se-Bum Park
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.4
    • /
    • pp.271-286
    • /
    • 2023
  • The global COVID-19 pandemic has transformed face masks from situational accessories to indispensable items in daily life, prompting a shift in public perception and behavior. While the relaxation of mandatory mask-wearing regulations is underway, a significant number of individuals continue to embrace face masks, turning them into a form of personal expression and identity. This phenomenon has given rise to the Fashion Mask industry, characterized by unique designs and colors, experiencing rapid growth in the market. However, existing research on masks is predominantly focused on their efficacy in preventing infection or exploring attitudes during the pandemic, leaving a gap in understanding consumer preferences for mask design. We address this gap by investigating consumer perceptions and preferences for two prevalent mask designs-horizontal fold flat masks and vertical fold flat masks. Through a comprehensive approach involving surveys and eye-tracking experiments, we aim to unravel the subtle differences in how consumers perceive these designs. Our research questions focus on determining which design is more appealing and exploring the reasons behind any observed differences. The study's findings reveal a clear preference for vertical fold flat masks, which are not only preferred but also perceived as unique, sophisticated, three-dimensional, and lively. The eye-tracking analysis provides insights into the visual attention patterns associated with mask designs, highlighting the pivotal role of the fold line in influencing these patterns. This research contributes to the evolving understanding of masks as a fashion statement and provides valuable insights for manufacturers and marketers in the Fashion Mask industry. The results have implications beyond the pandemic, emphasizing the importance of design elements in sustaining consumer interest in face masks.