• Title/Summary/Keyword: statement analysis

Search Result 599, Processing Time 0.022 seconds

Study on the Subjectivity about Nursing Student's Image of Professional Nurse before Clinical Practice (임상실습 전 간호대학생의 전문 간호사 이미지에 관한 주관성 연구)

  • Kim, Yun-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.224-234
    • /
    • 2014
  • This study designed to nursing student's image of professional nurse before clinical practice using Q-methodology. Using Q-methodology, 43 nursing student sorted 34 statements selected professional nurse type. The statement positions on the sorting continuum were scored from +4(representing the highest level of agreement) through 0(at the neutral position on the continuum) through -4(representing the highest level of disagreement). Factor analysis of the data was undertaken using PC QUANL software to determine if any patterns were discernible. The three factors extracted eigenvalues greater than 1.0 and explained approximately 53.94% of the variation in responses(41.63, 7.41 and 4.9% respectively). The categories were labeled 'Nightingale's nursing philosophy type', 'Consideration of patient type' and 'Self-development type'. Twenty-two students who located to factor 1 "Nightingale's nursing philosophy type". Eleven students who located to factor 2 "Consideration of patient type". Three students sho located to the factor 3 "Self-development type". The significant differences found in the subjective structure of nursing student's image of professional nurse. The study results can be utilized in both an effective nursing education and clinical practice.

Structuralization Expected Outcome of Social Welfare Program Based on Community Network : Using Concept Mapping Method (지역사회네트워크를 기반으로 한 사회복지프로그램 기대성과 구조화 : 컨셉트 맵핑(concept mapping)을 활용하여)

  • Kwon, Sunae
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.5
    • /
    • pp.107-116
    • /
    • 2014
  • The purpose of this study is to verify the applicability of concept mapping in the process of planning social welfare program based on community network. Concept mapping is a kind of decision-making method that structuralized complex ideas and presented visually. Already, concept mapping is widely utilized in counseling, nursing and public health area to plan and evaluation their program and service. For recent, effectiveness of concept mapping has been reported. Concept mapping is a effective decision-making method that they recognize outcome gap between service provider and client, reach the outcome's consensus in counseling and nursing, medical area. In this study, we conceptualized 3rd year outcomes of Community Impact Project that was supported from Busan Chest using concept mapping. This CI project intervenes children and youth who lives in Buk-gu, Busan. Concept mapping has six stages-preparation, collecting ideas, structuring statements, representing statement, interpreting the results of the analysis, applying the results. We followed these steps. The participants were working at social welfare organizations, total 11 persons. We obtained 60 statements and analyzed using multidimensional scaling. we collected 5 clusters, cluster 1 'awareness and attitude change of children and youth', cluster 2 'social system change of children and youth', cluster 3 'friendly community formation', cluster 4 'community people change', cluster 5 'service provider change'. As a result, among total 5 clusters formed, 'awareness and attitude change of children and youth' came to the strongest outcomes. When concept mapping was applied to the program planning, the consensus of the opinion came easily in the decision-making process, and the participants were empowered. In addition, clear conceptualization on each element of the program planning was made.

Effectiveness of Government R&D on Firm's R&D Spending (정부R&D투자가 기업 규모별 R&D지출에 미치는 영향 분석)

  • Jung, Jun-Ho;Kim, Jae-Soo;Choi, Ki-seok;Lee, Byeong-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.150-162
    • /
    • 2016
  • This study empirically analyze the effect of government R&D investment to find out whether it complements or substitutes for the firm R&D. In order to do it panel data set was constructed for the period of three years from 2012 to 2014 based on the number of 1301 data by utilizing national technology information service(NTIS) and publicly announced financial statement. Analysis was implemented in consideration of size of the firm(large corporation, small and medium sized firm) of which sample was obtained from only listed company. The result of two-way fixed effect model and two-way random effect model is as follows. In case of large corporation, government R&D investment has an effect of substitute for the company's R&D on the other hand, small and medium sized firm shows an complementary effect. It verifies that current R&D policy is appropriate. Therefore government's direct subsidy is expected to be successful to fertilize firm's innovation by allocating government R&D budget efficiently.

Improvement of Review System on Sea Area Utilization-Impact by Marine Environmental Management Law (해양환경관리법상 해역이용영향 검토기관의 발전방향)

  • Lee, Dae-In;Eom, Ki-Hyuk;Kim, Gui-Young;Jang, Ju-Hyoung
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.1
    • /
    • pp.55-62
    • /
    • 2008
  • This study investigated the status and problems of marine-related environmental impact assessment and a utilization-consultation system in Korea and suggested improvement of the review organization. Also, it conducted SWOT analysis based on evaluation of functions, roles and performance of the marine environmental impact assessment center and proposed development strategies of the center through introduction of expert opinions and advanced systems. The performance statement-review by the center in 2007 included 358 cases in total; 165 (46.1%) for consultation on utilization of sea area, 104 for environmental impact assessment (29.0%), and 89 (24.9%) for prior environmental review. The consultation on utilization of sea area can be divided into that for public water surface-use (41%) and reclamation (32%), and sea aggregate extraction process (21%). Although bad impacts on marine environment are reducing under the current system, there are some limits and problems to supplement it in terms of content, system and operation. Review system on sea area utilization-impact(marine environmental impact assessment center) by marine environmental management law needs to obtain expertise, fairness and efficiency and, to do so, have operational supports and institutional improvement to maximize its own functions and roles. At the same time, it is necessary for the center to establish identity and the status as a professional review organization by setting active development strategies inside the center. Finally, it should strengthen an consultation system of marine environmental impact assessment led by the related ministry to achieve effective coastal management.

  • PDF

REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT (교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴)

  • Yun, Young-Kuk;Ryu, Jae-Jun;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

Analysis of Curriculum Development Processes and the Relationship between General Statements of the Curriculum and Science Curriculum (교육과정 개발 체제 및 총론과 과학과 교육과정의 연계성 분석)

  • Lee, Yang-Rak
    • Journal of The Korean Association For Science Education
    • /
    • v.24 no.3
    • /
    • pp.468-480
    • /
    • 2004
  • It has been criticized that there are discrepancy between 'general statements' of the curriculum and subject-matter curricula. The possible reasons for this are as follows: The developers of the general statements were educational curriculum specialists. These specialists were not good enough to develop general statements and guidelines of subject matter curricula reflecting the characteristics of science contents, to examine developed science curriculum, and to give feedback to science curriculum developers. Under the present curriculum developing system where curriculum is developed in ten months or less by the research team commissioned unpredictably and imminently, it might be difficult to develop valid and precise science curriculum reflecting the purport of the general statements and teachers' needs. The inadequacy of these curriculum development processes resulted in (1) inconsistent statement about the school year to be applied to differentiated curriculum, (2) abstract and ambiguous stating about the characteristics, teaching-learning and assessment guidelines of enrichment activities, and (3) failure to reduce science contents to a reasonable level. Therefore curriculum development centers should be designated in advance to do basic research at ordinary times, and organized into a cooperative system among them. Two years or more of developing time and wider participation of scientists are recommended to develop more valid and precise science curriculum. In addition, commentaries on science curriculum should be published before textbook writing begins.

THE FRACTURE CHARACTERISTICS OF GLASS FIBER POST AND CORE ON USING DIFFERENT TYPES OF CORE RESIN MATERIALS

  • Shim Dong-Wook;Shim June-Sung;Lee Seok-Hyung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.280-293
    • /
    • 2004
  • Statement of problem. Glass fiber post is one of recent developments to accommodate esthetic restoration for endodontically treated teeth. This has many advantages over conventional post system in physical properties, esthetic factor, risk of root and restoration fracture, adhesion to core, radiopacity, removal and retrievabilty, biocompatibility and chemical stability. Purpose. This in vitro study was to evaluate the most suitable type of resin core for the glass fiber post through surveying the fracture modes and the maximum load that fractures the tooth. Material and methods. 50 sound maxillary premolars restored with glass fiber posts($ParaPost^{(R)}$ Fiber White) and different types of resin cores(ParaCore, $Z100^{TM}$, $Rebilda^{(R)}$ and $Admira^{(R)}$) were prepared and loaded to faiure in a universal test machine. The maximum fracture load and fracture mode were investigated in the specimens that were restored with resin and those of metal cast and core. With the data, Wilcoxon rank sum test was used to validate the significance between the test groups, and Tukey' s studentized range test was used to check if there is any significant statistical difference between each test group. Every analysis was approved with 95% reliance. Results. On measuring the maximum fracture load of teeth specimens, there was a significant difference between the maximum fracture loads of the tooth specimens. ParaCore showed the highest mean maximum fracture load followed by $Z100^{TM}$. And, the distribution of fracture mode of tooth specimens showed generally Type D, the three parted fracture of the core around the post was mostly seen(62.5%), and specifically, ParaCore showed 90% and $Z100^{TM}$ showed 100% Type D fracture. Conclusion. Referring to the values of maximum fracture load and mean compressive fracture load, ParaCore and $Z100^{TM}$ had high values and are recommended as tooth colored resin core material for glass fiber post. CLINICAL IMPLICATIONS. This study was carried out intending to be of aid in selecting the appropriate resin core for the glass fiber post. The dual cure type composite resin ParaCore and light cure type composite resin $Z100^{TM}$ have good properties and are recommended as tooth colored resin core material for glass fiber post.

A STUDY ON THE RESPONSES OF OSTEOBLASTS TO VARIOUS SURFACE-TREATED TITANIUM

  • Lee Joung-Min;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.307-326
    • /
    • 2004
  • Statement of problem. The long-term success of implants is the development of a stable direct connection between bone and implant surface, which must be structural and functional. To improve a direct implant fixation to the bone, various strategies have been developed focusing on the surface of materials. Among them, altering the surface properties can modify cellular responses such as cell adhesion, cell motility and bone deposition. Purpose. This study was to evaluate the cellular behaviors on the surface-modified titanium by morphological observation, cellular proliferation and differentiation. Material and methods. Specimens were divided into five groups, depending on their surface treatment: electropolishing(EP) anoclizing(AN), machining(MA), blasting with hydroxyapatite particle(RBM) and electrical discharge machining(EDM). Physicochemical properties and microstructures of the specimens were examined and the responses of osteoblast-like cells were investigated. The microtopography of specimens was observed by scanning electron microscopy(SEM). Surface roughness was measured by a three-dimensional roughness measuring system. The microstructure was analyzed by X-ray diffractometer(XRD) and scanning auger electron microscopy(AES). To evaluate cellular responses to modified titanium surfaces, osteoblasts isolated from neonatal rat were cultured. The cellular morphology and total protein amounts of osteoblast-like cell were taken as the marker for cellular proliferation, while the expression of alkaline phosphatase was used as the early differentiation marker for osteoblast. In addition, the type I collagen production was determined to be a reliable indicator of bone matrix synthesis. Results. 1. Each prepared specimen showed specific microtopography at SEM examination. The RBM group had a rough and irregular pattern with reticulated appearance. The EDM-treated surface had evident cracks and was heterogeneous consisting of broad sheet or plate with smooth edges and clusters of small grains, deep pores or craters. 2. Surface roughness values were, from the lowest to the highest, electropolished group, anodized group, machined group, RBM group and EDM group. 3. All groups showed amorphous structures. Especially anodized group was found to have increased surface oxide thickness and EDM group had titaniumcarbide(TiC) structure. 4. Cells on electropolished, anodized and machined surfaces developed flattened cell shape and cells on RBM appeared spherical and EDM showed both. After 14 days, the cells cultured from all groups were formed to be confluent and exhibited multilayer proliferation, often overlapped or stratified. 5. Total protein amounts were formed to be quite similar among all the group at 48 hours. At 14 days, the electropolished group and the anodized group induced more total protein amount than the RBM group(P<.05). 6. There was no significant difference among five groups for alkaline phosphatase(ALP) activity at 48 hours. The AN group showed significantly higher ALP activity than any other groups at 14 days(P<.05). 7. All the groups showed similar collagen synthesis except the EDM group. The amount of collagen on the electropolished and anodized surfaces were higher than that on the EDM surface(P<.05).

An Analysis on the Contents of the Health Related Articles in the Newspapers. (From the points of view of Health Education) (주요일간지의 건강관련기사내용 분석)

  • 김지미
    • Korean Journal of Health Education and Promotion
    • /
    • v.3 no.1
    • /
    • pp.29-42
    • /
    • 1985
  • The purpose of this study was to evaluate the educatconal function of the health related articles. The health articles of the four major daily newspapers from Jan. 1st, 1980 to Dec. 31th, 1984 were used and examined for the study. Editorials were excluded. The major results were summarized as follows: 1. The total number of the health articles subjected to the study in the four major daily newspapers was 4,431. On the whole, the health articles were appeared most frequently in 1981. As for monthly distribution, the health articles were appeared most frequently on June.(9.3%). As for weekly distribution, the health articles were appeared most frequently on wednesday and saturday(50.8%). As for the subjects of content; the health articles related to the health & disease management were appeared most frequently(52.8%), but the health articles on industrial health were showed least frequently(0.6%). 2. Reviewing the chronological trend of the health articles, the frequency of appearance of the public health administration was tended to increase year by year, whereas that of enviornmental health, industrial health and population decrease relatively. As for appealing method, it was observed that the articles providing health information were steadily increasing. As for the motives of writing the health articles, there was a tendency that seasonal motive, symphosium & seminar and compaign were increasing, but motive of legislative action and administrative action were gradually decreasing. As for type of the health articles, it was observed that interpretation and research result were steadily increasing. As for the writer of the health articles, there was a tendency that writing by reporter was increasing, whereas writing by experts was decreasing. As for tone of head, the health articles written by identification statement was tended to increase. As for the appearance of photograph & cut, it was observed that the health articles excluding photograph & cut were increasing. 3. When contents were analyzed by subjects, for the purpose of providing information was used most frequently as appealing method for all subjects. As for the motive of writing, "from the interest of writers" was most frequent. As for the type of articles, interpretation type was most prevalent for the public health administration, enviornmental health, food hygrene & nutrition, population and health behavior, while contribution by experts was most frequent for the health & disease management. As for the size of articles, all subjects except the population were appeared most frequently on the column. size between 100㎠ and 199㎠.

  • PDF

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.