• 제목/요약/키워드: starting system

검색결과 1,513건 처리시간 0.028초

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

고도모사용 2 차목 초음속 디퓨져 시동특성에 영향을 미치는 파라미터에 관한 연구 (Investigation of the essential parameters governing starting characteristic in the second throat exhaust diffuser for high altitude simulation)

  • 박성현;박병훈;임지환;윤웅섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2642-2647
    • /
    • 2008
  • Starting characteristics of the axi-symmetric supersonic exhaust diffuser(SED) with a second throat are numerically investigated. Main purpose of this study is to predict theoretical starting pressure of STED using 1-D normal shock theory and to present the range of optimum starting pressure through parametric study with essential design parameters of STED influencing on starting performance. Renolds-Average Navier-Stokes equations with a standard ${\kappa}-{\varepsilon}$ turbulence model incorporated with standard wall function are solved to simulate the diffusing evolutions of the nozzle plume. Minimum(optimum) starting pressure difference of $20{\sim}25%$ between 1-D theory and experimental evidences validated from previous results[5] is also applied to predict those in this system. The analysis results indicate that dominant parameters for diffuser starting in this system is diffuser expansion ratio($A_d/A_t$), which has optimum value 120 and second throat area ratio($A_d/A_{st}$), which has optimum range $3.3{\sim}3.5$.

  • PDF

TBM용 대용량 전동기의 기동 특성 및 개선 관한 연구 (A Study on Starting Characteristic and Improvement for High Power Motor with Tunnel Boring Machine)

  • 김태규;안준영
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.44-51
    • /
    • 2019
  • Tunnel Boring Machine's Technology has depends mostly on imports, currently domestic technology development was proceeding. There are many technologies in this field, above all, the large-capacity motor drive technology required for excavation is one of the core technologies. In particular, when several large motors are simultaneously starting, there are many problems due to a large starting current at that time, and it is difficult to design and operate a power receiving facility. In this paper, A method of reducing the starting current by using the regenerative power generated by the deceleration of the motor has been studied. To verify this proposal, we designed the induction motor controller using CAE based power simulation tool and verified the results of the proposed method by applying the reduced model. As a result, it is possible to reduce the maximum starting current and shorten the start-up time. Moreover, even if several motors are connected to one bank, it is proved that the method can be efficiently operated by using the sequential braking / starting sequence. In the case of a power system in which a large capacity electric motor such as a tunnel excavation system is driven, the results of this study are expected to be a stable and effective method for solving the start-up current problem and designing the power receiving facility.

주권선 전류검출에 의한 단상유도전동기의 구동시스템 구현 (The Starting System Implementation of SPIM with Detecting Main Winding Current)

  • 최낙일;박수강;오금곤;백형래;임양수;오기진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.166-170
    • /
    • 1997
  • A Single phase induction motor is the predominant fractional horsepower power rated, extensively used in domestic and industrial application. For example, these motors provide the motive power to washing machines, fans, refrigerators, etc. In this paper, single phase induction motor input current was detected by a small current transformer and determined TRIAC gate signal by using op-amp analog circuit. The soft-start strategy is based on limited auxiliary current angle during starting period in the closed-loop control. The Simulation and experimental result show the motor's starting characteristics of the proposal starting system and are compared with centrifugal switch starting motor.

  • PDF

고토크 스타터에 의한 마이크로 하이브리드 엔진의 시동특성 개선 효과 (The Effects of High Torque Starters on the Starting Characteristics of a Micro-hybrid Engine)

  • 김성수
    • 동력기계공학회지
    • /
    • 제14권2호
    • /
    • pp.12-15
    • /
    • 2010
  • It is requested to shorten the starting duration for idle stop function equipped cars without harmful effects on the environment. Higher cranking speeds can be achieved with high torque starter. The object of this study is to develope the high torque starter and evaluate its effect on the exhaust emissions. The test was conducted on a 1.5 L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine. Engine out emissions such as HC, CO, $CO_2$, and the excess air ratios, lambda were measured using MEXA-554JK. The result showed that a high torque starter, HTS-II shortened the starting duration and reduced engine out emissions of HC, CO and improved starting performance with larger excess air ratio than that of the original starter, Org. S and a high torque starter, HTS-I.

기동시뮬레이션 방법에 의한 유도전동기 기동방식 선정 (Selection of Motor Starting Method by Numeric Simulation)

  • 장중구;서상진;이민용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.817-820
    • /
    • 2002
  • Since a squirrel cage induction motor by NEMA Design types is designed to withstand full-voltage starting, direct starting method can be the most economical one. Starting a squirrel cage motor from standstill by connecting it directly across the line may allow inush currents of approximately 500-600% of rated current at lagging power factor of 35-50%. For many of the large motors, the starting inrush current may be great enough to cause voltage dips, which may adversely affect the building's lighting system. Electric utilities also have restrictions on starting currents, so that voltage fluctuations can be held to prescribed limits. Therefore the need for choosing the most appropriate method of motor starting is quite essential. In this paper, we proposed a plan for the selection of the most appropriate motor starting method, first by way of numeric simulation using manufacturer's data and second by way of actual experience. So far, more often than not, the selection of motor starting method has been accomplished only as regards to the capacity of the motor and the frequency of starting and stopping. But nowadays such high-tech apparatus as soft starters are being developed, and we are on the position to give more attention to clarify the way of selection of the motor starting method.

  • PDF

이동식발전설비의 기동전동기용 전자식 시동 제어장치 개발 (Development of an Electronic Starting Controller for Starting Motor of Packaged Power Systems)

  • 김종수;윤경국;서동환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.700-706
    • /
    • 2012
  • 이동식발전설비에서 시동장치의 핵심기술은 피니언기어 쉬프팅 장치와 초기 기동전압을 제한하는 것이며 기존의 제품에서는 기계적 주접점을 이용한 시동 제어장치를 사용하고 있다. 하지만 완전한 피니언기어 쉬프팅 후 시동전동기의 기동의 불확실성이나 대전류에 의한 주접점의 아크손상 등의 큰 문제점을 가지고 있다. 본 연구에서는 이러한 문제점을 해결하기 위해 기동의 불확실성 제거를 위한 피니언기어 쉬프팅 제어회로, 대전류에 의한 접점의 아크손상 방지를 위해 반도체 소자를 이용한 시동 제어시스템, 직권전동기의 소프트 스타팅을 위한 기동 안전장치 등을 새롭게 설계, 제작하여 안전성과 신뢰성을 얻고자 하였다. 또한, 피니언기어 제어회로와 전동기 전원회로를 분리하여 전기적 안전성을 확보하였다.

SIMULATION OF STARTING PROCESS OF DIESEL ENGINE UNDER COLD CONDITIONS

  • Park, J.K.
    • International Journal of Automotive Technology
    • /
    • 제8권3호
    • /
    • pp.289-298
    • /
    • 2007
  • A nonlinear dynamic simulation model from cranking to idle speed is developed to optimize the cold start process of a diesel engine. Physically-based first order nonlinear differential equations and some algebraic equations describing engine dynamics and starter motor dynamics are used to model the performance of cold starting process which is very complex and involves many components including the cold start aiding method. These equations are solved using numerical schemes to describe the starting process of a diesel engine and to study the effects of cold starting parameters. The validity of this model is examined by a cold start test at $-20^{\circ}C$. Using the developed model the effects of the important starting variables on the cold starting processes were investigated. This model can be served as a tool for designing computer aided control systems that improve cold start performance.

기동방식을 고려한 DC급전계통 보호알고리즘 (A Protection Algorithm for DC Railway Systems Considering Train Starting)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.307-309
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

  • PDF

Simulink에서 계통연계 풍력발전시스템의 전압변동 시뮬레이션 (Simulation for Voltage Variations of a Grid-connected Wind Turbine Generation System by Simulink)

  • 안덕근;노경수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.589-595
    • /
    • 2004
  • This paper presents a modeling and simulation of a grid-connected wind turbine generation system with respect to wind variations, starting of large induction motor and three-phase fault in the system, and investigates voltage variations of the system for disturbances. It describes the modeling of the wind turbine system including the drive train model, induction generator model, and grid-interface model on MATLAB/Simulink. The simulation results show the variation of the generator torque, the generator rotor speed, the pitch angle, terminal voltage, system voltage, fault current, and real/reactive power output, etc. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction for wind speed variations, starting of a large induction motor causes a voltage sag due to a large starting current, and a fault on the system influences on the output of the wind turbine generator.