A Protection Algorithm for DC Railway Systems Considering Train Starting

기동방식을 고려한 DC급전계통 보호알고리즘

  • 권영진 (명지대학교 차세대전력기술연구센터) ;
  • 최동민 (명지대학교 차세대전력기술연구센터) ;
  • 강상희 (명지대학교 차세대전력기술연구센터) ;
  • 한문섭 (철도기술연구원) ;
  • 이재경 ((주)젤파워)
  • Published : 2004.07.14

Abstract

A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

Keywords