• Title/Summary/Keyword: standardized values

Search Result 428, Processing Time 0.03 seconds

The Biological Stability of Immediate Placement of Tapered Implants in Tooth Extraction Sites (발치와에 즉시 식립한 쐐기형 임플란트의 생물학적 안정성에 관한 전향적 연구)

  • Park, Ja-young;Bae, Ahran;Kim, Hyung-Seub;Kwon, Yong-Dae;Lee, Baek-Soo;Kwon, Kung-Rock
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.139-155
    • /
    • 2009
  • Objective : To assess the biological stability of immediate transmucosal placement of tapered implants into tooth extraction sockets. Material and methods : Following tooth extraction, tapered implants were immediately placed into the sockets. Teeth with evidence of acute periapical pathology were excluded. After implant placement, sutured allowing a non-submerged, transmucosal healing. Standardized radiographs were obtained every visiting from baseline to 32 weeks after implant placment. Changes in depth of the distance from the implant shoulder (IS) and from the alveolar crest (AC) to the bottom of the defect (BD) were assessed. Results : Thirteen patients (10 males and 3 females) were enrolled and followed. They contributed with 15 tapered implants. extraction iste displayed sufficient residual bone volume to allow primary stability of all implants. The mean surgery time was $41{\pm}10.0$ mins. All implants healed uneventfully yielding a survival rate of 100%. Mean ISQ values were relatively stable. Interproximal crestal bone decreased $1.69{\pm}1.2mm$ (mesial), $1.65{\pm}1.2mm$ (distal) from baseline to 32-week follow-up. No statistically significant changes with respect to FMPS, FMBS, PPD and width of KG were observed. Conclusions: Immediate transmucosal implant placement represented a predictable treatment option for the replacement of teeth lost due to reasons including fractures, endodontic failures and caries.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Correlation Analysis between Climatic Factors and Radial Growth and Growth Prediction for Pinus densiflora and Larix kaempferi in South Korea (소나무와 일본잎갈나무의 연륜생장과 기후 요소와의 상관관계 분석 및 생장예측)

  • Chung, Junmo;Kim, Hyunseop;Kim, Meesook;Chun, Yongwoo
    • Journal of Korean Society of Forest Science
    • /
    • v.106 no.1
    • /
    • pp.77-86
    • /
    • 2017
  • This study was conducted to analyze the relationship among climatic factors and radial growth of Pinus densiflora and Larix kaempferi in South Korea. To determine the climate-growth relationship, cluster analysis was applied to group surveyed regions by the climatical similarity, and a dendroclimatological model was developed to predict radial growth for each climate group under the RCP 4.5 and RCP 8.5 scenarios for greenhouse gases. The cluster analysis showed four climatic clusters (Cluster 1~4) from 10 regions for P. densiflora and L. kaempferi. The dendroclimatological model was developed through climatic variables and standardized residual chronology for each climatic cluster of P. densiflora and L. kaempferi. Four climatic variables were used in the models for P. densiflora ($R^2$ values between 0.38 to 0.58). Two to five climatic variables were used in the models for L. kaempferi ($R^2$ values between 0.31 to 0.43). The growth simulations with two RCP climate-change scenarios(RCP 4.5 and RCP 8.5) were used for growth prediction. The radial growth of the Cluster 4 of P. densiflora, the mountainous region at high elevation, tend to increase, while those of cluster 2 and 3 of P. densiflora, the region of the hightest average temperature, tends to decrease. The radial growth of the Cluster 1 of L. kaempferi the region of the lowest minimum temperature, while that of Cluster 2, the region of the highest average temperature, tends to decrease. The radial growth of Cluster 3 of L. kaempferi, the region in the east coast and Cluster 4, the region at high elevation, tends to hold steady. The results of this study are expected to provide valuable information necessary for predicting changes in radial growth of Pinus densiflora and Larix kaempferi caused by climate change.

Changes of Hemodynamic and Central Pulmonary Artery Dimension After Bidirectional Cavopulmonarv Shunt (양방향성 체정맥-폐동맥 단락술후 혈역학 및 중심 폐동맥 크기의 변화)

  • 이정렬;이해원
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1306-1315
    • /
    • 1996
  • This study reviewed the changes of hemodynamlcs and centrAl pulmonary artery dimension in 54 patients who underwent bidirectional cavopulmonary shunt(BCPS) between February 1992 and December 1995 at Seoul National University Childrell's Hospital. Ag and body weight of patients averaged 36.8 $\pm$ 37.7 months and 8.0$\pm$3.0 kg, respectively Eightynine percent of patients had more than 2 violations of the risk factors for Fontan operation, resulting overall hospital mortality of 16.6%(9154). Serial hemodynamic and anglographic examinations before and mean 16.3 $\pm$ 14.3 months iirter BCPS were compared. The arterial oxygen saturation improved from a preoperative value of 71 9: 10.1 % to 79.H $\pm$ 8. 5% (n:4), p<0.05). The values of arterial oxygen saturation were lower as the age of the patients with BCPS in place was older(n=22, R'=0.341, p=0.004). A mean pulmonary artery pressure and pulmonary vascular resistance reduced from 31 $\pm$17 to 1).5$\pm$3.SmmHg(n=22, p<0.05) and from ).2$\pm$2.1 to 2.3$\pm$2.7 unit (n=7. p>0.05), respectively. Follow-up study showed a significant Increase of absolute values of ipsilateral pulmoanry artery (n: 14, p<0.05), but no change of contralateral pulmonary artreries (n: 14. p=not significant(HSI). However, there w re significant decreases in diameters of both ipsilateral and contralateral pulmonary arteries standardized by patients' body surface areas(16.8% decrease, n: 14, p< 0. 05 for ipsilatreal, 25.1%, n=14, p<0.05 for contralateral). Pulmonary artery indices for cross sectional areas of both pulmonary arterises decreased 9.3 $\pm$ 13.8% with showing a trend of more decrease as the follow-up duration was longer, We conclude that the bidirectional cavopulmonary shunt provide an excellent.

  • PDF

The Effectiveness of Sympathetic Skin Response Studies for Patients with Primary Palmar Hyperhidrosis and Who Undergo Thoracic Sympathicotomy (일차성 수부 다한증에서 교감신경절제술 후 교감신경 피부반응 검사의 효용성)

  • Yoon, Jeong-Seob;Sim, Sung-Bo;Rhee, Won-Ihl
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.738-743
    • /
    • 2009
  • Background: There is no standardized tool and parameter that can accurately assess the sympathetic function before and after performing sympathectomy in patients with primary palmar hyperhidrosis. We examined the effective-ness of the sympathetic skin response (SSR) study for documenting the change of sympathetic denervation before and after performing selective thoracic sympathicotomy. Material and Method: We prospectively investigated the SSR from 12 healthy subjects who were diagnosed with primary hyperhidrosis. Each SSR was recorded on the right palm or sole with electrical stimuli applied to the skin at the left wrist and foot and vice versa for the controlateral side. This test was performed before, 2 weeks and 1 year after selective thoracic sympathicotomy. The data was corrected for the onset latency and the amplitude of the SSR (n=24). Result: The mean age of the 12 patients was $24.6{\pm}0.4$ years (range: 19~36) and the gender ratio was 1 : 0.7. The mean values of the preoperative, postoperative 2 weeks and postoperative 1 year onset latency and amplitude of the palmar side (n=24) were $1.46{\pm}0.24$ msec and $6,043{\pm}2,339{\mu}V$, $1.63{\pm}0.42$ msec and $823{\pm}638{\mu}V$, and $1.44{\pm}0.39$ msec and $2,412{\pm}1,546{\mu}V$, respectively. The mean values of the plantar side (n=38) were $1.83{\pm}0.42$ msec and $2,816{\pm}1,694{\mu}V$, $2.16{\pm}0.39$ msec and $1,445{\pm}1,281{\mu}V$ and $1.95{\pm}0.25$ msec and $1,622{\pm}865{\mu}V$, respectively. Among the documented parameters, only the palmar amplitude (p=0.002) showed statistical significance in recording the change of the sympathetic system within the same individual for the pre and postoperative period. Conclusion: The SSR amplitude ratio may be a useful parameter for documenting the efficacy of sympathetic denervation after selective sympathicotomy.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Behavior of Truss Railway Bridge Using Periodic Static and Dynamic Load Tests (주행 열차의 정적 및 동적 재하시험 계측 데이터를 이용한 트러스 철도 교량의 주기적 거동 분석)

  • Jin-Mo Kim;Geonwoo Kim;Si-Hyeong Kim;Dohyeong Kim;Dookie Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.120-129
    • /
    • 2023
  • To evaluate the vertical loads on railway bridges, conventional load tests are typically conducted. However, these tests often entail significant costs and procedural challenges. Railway conditions involve nearly identical load profiles due to standardized rail systems, which may appear straightforward in terms of load conditions. Nevertheless, this study aims to validate load tests conducted under operational train conditions by comparing the results with those obtained from conventional load tests. Additionally, static and dynamic structural behaviors are extracted from the measurement data for evaluation. To ensure the reliability of load testing, this research demonstrates feasibility through comparisons of existing measurement data with sensor attachment locations, train speeds, responses between different rail lines, tendency analysis, selection of impact coefficients, and analysis of natural frequencies. This study applies to the Dongho Railway Bridge and verifies the applicability of the proposed method. Ten operational trains and 44 sensors were deployed on the bridge to measure deformations and deflections during load test intervals, which were then compared with theoretical values. The analysis results indicate good symmetry and overlap of loads, as well as a favorable comparison between static and dynamic load test results. The maximum measured impact coefficient (0.092) was found to be lower than the theoretical impact coefficient (0.327), and the impact influence from live loads was deemed acceptable. The measured natural frequencies approximated the theoretical values, with an average of 2.393Hz compared to the calculated value of 2.415Hz. Based on these results, this paper demonstrates that for evaluating vertical loads, it is possible to measure deformations and deflections of truss railway bridges through load tests under operational train conditions without traffic control, enabling the calculation of response factors for stress adjustments.

Comparative Analysis of Ginsenoside Content in Processed Red Ginseng Foods Based on Food Type and Formulation (홍삼가공식품의 식품유형별 및 제형별 진세노사이드 함량 비교)

  • Yun-Jeong Yi;Min-Su Chang;In-Sook Lee;Hyun-Jeong Kim;Hyun-Jeong Jang;In-Sook Hwang
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.2
    • /
    • pp.163-170
    • /
    • 2024
  • Red ginseng is manufactured as a health-functional food and is also present in various food types and in different product forms. However, there is currently no standardized regulation of ginsenoside content in foods containing red ginseng. In the present study, we analyzed the ginsenoside content of 66 red ginseng-containing foods and 35 health-functional foods collected online and directly from the market. The ginsenoside content was assessed using liquid chromatography (LC) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. The ginsenoside content of the various food types ranged 0.0 (not detected)-71.567 mg per daily intake of foods containing red ginseng. Sugar-preserved foods had the highest ginsenoside content, followed by solid teas, liquid teas, and red ginseng beverages. For health-functional foods, the ginsenoside content ranged 3.4-58.5 mg per daily intake, with levels ranging 83-607% of the indicated amounts. All values met the established standards. Upon comparing red ginseng health-functional foods and red ginseng-containing foods, the average ginsenoside content was determined to be 18.21 and 8.79 mg, respectively, thus being nearly twice as high in health-functional foods. However, there was a minimal difference between the ginsenoside content of red and black ginseng, with values of 11.84 and 12.63 mg, respectively. These findings provide insights on the variations in ginsenoside content of red and black ginseng in various food forms. This information is expected to be valuable for future regulations and consumer choice of products containing red ginseng.

A Study of the New Positioning Guide Based on the Correlation between the Orbit Meatus Line and Mandibular Body Angle in Paranasal Sinus Parietoacanthial Projection(Water's Method) (코곁굴 두정비극방향 검사 시 안와이공선과 아래턱뼈 몸통각도의 상관관계를 이용한 새로운 자세잡이 기준에 관한 연구)

  • Yong-Min Son;Han-Yong Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.335-344
    • /
    • 2024
  • In this study, we aim to investigate the correlation between the lateral images of Korean skulls and the angle between the OML and the Body of the Mandible. Additionally, we seek to provide criteria for the ease of positioning in clinical settings and establish standardized imaging procedures for the PNS Water's view examination. This study was conducted on a total of 202 patients who visited the radiology department of a general hospital and examined the skull lateral radiography. In addition to the patient images, skull phantoms were also utilized, and images were obtained using GC85A and EOS equipment. In this research, abbreviations related to the angle of the Body of Mandible were defined using PACS on lateral images. Measurements were taken for various angles, including ramus of mandible angle(RIA), accurate OML angle(TIA), OML and IR Angle(OIA), total mandibular length(TML), ramus height(RH), the angle between the pogonion, gonion, and condylion(MA). The validity of these measurements was confirmed using the skull phantom in the study. The age-specific average range for RIA was 22.67° to 26.04°, with measurements of 23.14° for males and 24.78° for females. The age-related mean ranges for TIA and OIA were 35.98° to 38.31° and 72.27° to 75.25°, respectively. For males, TIA was 36.74° and OIA was 72.73°, while for females, TIA was 36.43° and OIA was 73.38°. The age-dependent measurements for TML and RH ranged from 85.73 mm to 89.60 mm and 62.60 mm to 70.87 mm, respectively. Male values were 90.54 mm and 70.78 mm, while female values were 85.13 mm and 61.54 mm for TML and RH, respectively. The age-specific average range for MA was 55.95° to 58.63°, with measurements of 57.96° for males and 57.76° for females. Correlation analysis revealed a positive correlation between RIA and OIA, as well as between RIA and TIA. Based on the results of this study, which indicate a positive correlation between the angle of the Body of Mandible and the OML, it can be inferred that adjusting the mandible vertically to align with the imaging receptor may contribute to more accurate image acquisition during PNS Water's view examination. Therefore, it is believed that there is value in utilizing this relationship as a criterion for establishing new positioning standards, which could enhance the utility of a new positioning guide.

The Relationship Between DEA Model-based Eco-Efficiency and Economic Performance (DEA 모형 기반의 에코효율성과 경제적 성과의 연관성)

  • Kim, Myoung-Jong
    • Journal of Environmental Policy
    • /
    • v.13 no.4
    • /
    • pp.3-49
    • /
    • 2014
  • Growing interest of stakeholders on corporate responsibilities for environment and tightening environmental regulations are highlighting the importance of environmental management more than ever. However, companies' awareness of the importance of environment is still falling behind, and related academic works have not shown consistent conclusions on the relationship between environmental performance and economic performance. One of the reasons is different ways of measuring these two performances. The evaluation scope of economic performance is relatively narrow and the performance can be measured by a unified unit such as price, while the scope of environmental performance is diverse and a wide range of units are used for measuring environmental performances instead of using a single unified unit. Therefore, the results of works can be different depending on the performance indicators selected. In order to resolve this problem, generalized and standardized performance indicators should be developed. In particular, the performance indicators should be able to cover the concepts of both environmental and economic performances because the recent idea of environmental management has expanded to encompass the concept of sustainability. Another reason is that most of the current researches tend to focus on the motive of environmental investments and environmental performance, and do not offer a guideline for an effective implementation strategy for environmental management. For example, a process improvement strategy or a market discrimination strategy can be deployed through comparing the environment competitiveness among the companies in the same or similar industries, so that a virtuous cyclical relationship between environmental and economic performances can be secured. A novel method for measuring eco-efficiency by utilizing Data Envelopment Analysis (DEA), which is able to combine multiple environmental and economic performances, is proposed in this report. Based on the eco-efficiencies, the environmental competitiveness is analyzed and the optimal combination of inputs and outputs are recommended for improving the eco-efficiencies of inefficient firms. Furthermore, the panel analysis is applied to the causal relationship between eco-efficiency and economic performance, and the pooled regression model is used to investigate the relationship between eco-efficiency and economic performance. The four-year eco-efficiencies between 2010 and 2013 of 23 companies are obtained from the DEA analysis; a comparison of efficiencies among 23 companies is carried out in terms of technical efficiency(TE), pure technical efficiency(PTE) and scale efficiency(SE), and then a set of recommendations for optimal combination of inputs and outputs are suggested for the inefficient companies. Furthermore, the experimental results with the panel analysis have demonstrated the causality from eco-efficiency to economic performance. The results of the pooled regression have shown that eco-efficiency positively affect financial perform ances(ROA and ROS) of the companies, as well as firm values(Tobin Q, stock price, and stock returns). This report proposes a novel approach for generating standardized performance indicators obtained from multiple environmental and economic performances, so that it is able to enhance the generality of relevant researches and provide a deep insight into the sustainability of environmental management. Furthermore, using efficiency indicators obtained from the DEA model, the cause of change in eco-efficiency can be investigated and an effective strategy for environmental management can be suggested. Finally, this report can be a motive for environmental management by providing empirical evidence that environmental investments can improve economic performance.

  • PDF