• Title/Summary/Keyword: standardized

Search Result 6,009, Processing Time 0.04 seconds

A Study on the Component-based GIS Development Methodology using UML (UML을 활용한 컴포넌트 기반의 GIS 개발방법론에 관한 연구)

  • Park, Tae-Og;Kim, Kye-Hyun
    • Journal of Korea Spatial Information System Society
    • /
    • v.3 no.2 s.6
    • /
    • pp.21-43
    • /
    • 2001
  • The environment to development information system including a GIS has been drastically changed in recent years in the perspectives of the complexity and diversity of the software, and the distributed processing and network computing, etc. This leads the paradigm of the software development to the CBD(Component Based Development) based object-oriented technology. As an effort to support these movements, OGC has released the abstract and implementation standards to enable approaching to the service for heterogeneous geographic information processing. It is also common trend in domestic field to develop the GIS application based on the component technology for municipal governments. Therefore, it is imperative to adopt the component technology considering current movements, yet related research works have not been made. This research is to propose a component-based GIS development methodology-ATOM(Advanced Technology Of Methodology)-and to verify its adoptability through the case study. ATOM can be used as a methodology to develop component itself and enterprise GIS supporting the whole procedure for the software development life cycle based on conventional reusable component. ATOM defines stepwise development process comprising activities and work units of each process. Also, it provides input and output, standardized items and specs for the documentation, detailed instructions for the easy understanding of the development methodology. The major characteristics of ATOM would be the component-based development methodology considering numerous features of the GIS domain to generate a component with a simple function, the smallest size, and the maximum reusability. The case study to validate the adoptability of the ATOM showed that it proves to be a efficient tool for generating a component providing relatively systematic and detailed guidelines for the component development. Therefore, ATOM would lead to the promotion of the quality and the productivity for developing application GIS software and eventually contribute to the automatic production of the GIS software, the our final goal.

  • PDF

Comparison Study on Efficacies of Disinfectants and Sanitizers Among Methods for Quantitative Surface Test (살균소독제의 정량적 표면시험방법별 유효성 비교)

  • Kim, Ae-Young;Kim, Yong-Su;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.238-244
    • /
    • 2010
  • Currently, in vitro suspension tests using tubes are used as a authorized test method for sanitizers and disinfectants. However, the methods could not accurately assess the efficacy of sanitizers and disinfectant on the food-contacted surfaces in the field. This study evaluated the effectiveness of 5 kinds of representative sanitizers and disinfectants against E. coli and S. aureus to compare three quantitative surface testing methods that have been internationally standardized. As a result, the ASTM E2111-05 (ASTM(1)) test method obtained 5.18 $\pm$ 0.03 and 5.27 $\pm$ 0.04 log cfu/carrier reduction in dealing with E. coli and S. aureus, respectively, the ASTM E2197-02 (ASTM(2)) test method obtained 4.63 $\pm$ 0.04 and 3.97 $\pm$ 0.03 log cfu/carrier reduction and the CEN EN 13697 test method should 6.14 $\pm$ 0.05 and 5.31 $\pm$ 0.10 log cfu/carrier reduction in clean condition (CEN(1)) but 4.37 $\pm$ 0.02 and 4.06 $\pm$ 0.01 log cfu/carrier reduction in dirty condition (CEN(2)). Among them, CEN(1) showed the highest bactericidal effects, whereas ASTM(2) and CEN(2) revealed low performance (p < 0.05). In conclusion, the bactericidal effects of the ASTM(2) method and the CEN EN 13697 method adopting stainless steel were lower than the ASTM(1) method, which uses glass. The effectiveness assessment results among nationally accredited test methods were different each other. This implies that they could not fit for in the accurate evaluation of sanitization and disinfection on food-contact surfaces in practical food-processing fields. These results could be used as a basic data for establishment of an official surface test methods applicable in the field.

Biological Activity and Improvement Effect on Irritable Bowel Syndrome of Wax Gourd Extract and Probiotic Lactic Acid Bacteria (동아 추출물과 프로바이오틱 유산균의 생리활성 및 과민성대장증후군 개선 효과)

  • Ann, Yong-Geun;Jang, Byeong-Churl;Park, Se-Joon
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.1
    • /
    • pp.137-145
    • /
    • 2013
  • Biological activities of wax gourd (Benincase hispida) extract and lactic acid bacteria (Lactobacillus casei and Bifidobacterium bifidum) were investigated in this study. Wax gourd extract reduced the activity of angiotensin-converting enzyme (ACE) by 47.9%, of tyrosinase by 13.2%, and had an anti-oxidant activity of 23.4%. Oral administration of wax gourd extract for 72 hours improved the symptom of loose bowels for 120 patients with its highest improvement rates within 6 to 12 hours. The improvement rates were standardized by the curative state by 80%. Lactic acid bacteria preparations reduced the activity of ACE by 21.49%. Oral administration of lactic acid bacteria preparations for 72 hours improved the symptom of loose bowels for 108 patients with its highest improvement rates after 24 hours. On the basis of these results, the tablets containing both wax gourd extract and lactic acid bacteria preparations for the improvement of irritable bowel syndromes were developed. The tablets reduced the activity of ACE by 27.1% and exhibited an anti-oxidant activity of 20.3%. Treatment of the tablets at 100 ${\mu}g/m{\ell}$ and 250 ${\mu}g/m{\ell}$ for 24 hours inhibited the growth of A549 human lung cancer cells by 67%, which was much higher than that of each wax gourd extract or lactic acid bacteria. In addition, treatment of the tablets at 100 ${\mu}g/m{\ell}$ for 24 hours reduced the growth of HCT-116 human colon cancer cells by 70%. Oral administration of the tablets to the patients with loose bowels led to higher improvement rates and speed than each wax gourd extract or lactic acid bacteria. Oral administration of the tablets to the patients with irritable bowel syndromes of loose bowels, constipation, or general type for 72 hours improved their symptoms by 100% with the highest improvement rates within 3 to 6 hours. Furthermore, the improvement rates and speed by the tablets was much higher than each wax gourd extract or lactic acid bacteria.

Technical Efficiency of Medical Resource Supply and Demand (의료자원 공급, 수요의 성과 효율성에 대한 실증분석)

  • Chang, Insu;Ahn, Hyeong Seok;Kim, Brian H.S.
    • Journal of the Korean Regional Science Association
    • /
    • v.34 no.2
    • /
    • pp.3-19
    • /
    • 2018
  • The objective of this study is to observe the efficiency of clinical performance on the supply and demand of medical resources in Korea. For the empirical analysis, we constructed the dataset on age standardized mortality rate, the number of physician, specialist, surgery, medical institution, ratio of general hospitals of 16 provinces in Korea from 2006 to 2013. The panel probability frontier model is employed as an analysis method and considered heteroscedasticity and autocorrelation of the error in panel data. In addition, the demographic and socioeconomic characteristics of the 16 provinces, unemployment rate, elderly population ratio, GRDP per capita, and ratio of hospitals in comparison to the general hospitals are used to find the effect on the technical efficiency of clinical performance on supply and demand of medical resources. The results are as follows. First, for the clinical performance, the supply side of human resources such as doctors and specialists and the demand side factors such as chronic illness clinic per unit population have a significant influence, respectively. Second, the technical efficiency of clinical performance on the supply and demand of medical resources of each input component was 59-70% in terms of clinical efficiency in each region. Third. estimates of technical efficiency of inputs that affect clinical performance showed a slight increase in all regions during the analysis period, but the increase trend decreased slightly. Fourth, the ratio of the elderly population and GRDP per capita have a positive influence on the technical efficiency of clinical performance on the supply and demand of medical resources. The difference of each efficiency by region is due to the regional differences of the input medical resources and the combination of them and the demographic and socioeconomic characteristics of the region. It is understood that the differences in technological efficiency due to the complexity of supply and demand of medical resources, demographic structure and economic difference affecting clinical performance by region are different.

The Study on the Plan to Introduce Traffic Inducement Security System in Korea (우리나라 교통유도경비 도입방안의 연구)

  • Kim, Tae-Hwan
    • Korean Security Journal
    • /
    • no.23
    • /
    • pp.21-39
    • /
    • 2010
  • The dangerous impact on the traffic flows of cars is caused by no only the construction on the street but diverse construction sites. This in turn substantially influence on the citizens and pedestrians, thereby bring about the possibility of giant incidents. As the countermeasure for the problem in advanced countries, particularly in Japan "traffic inducement security system" has been implemented. It is analyzed that the death toll from traffic accidents has considerably declined. In the case of South Korea the system has not been administered but restrictively executed at some construction sites; however proceeding it with the lack of professionalism. The introduction of traffic inducement security system would be the opportunity for South Korea to make a progress in the safety culture such as traffic security and traffic jam. This study thus aims at analyzing the advanced countries' cases, conducting comparative analysis with Korea's scheme, and establishing the plan to adopt the traffic inducement security system. Through the output of this study followings were proposed as plans of introducing the traffic inducement security system. First of all, legal assessments regarding traffic inducement operation, for example adding the operation of the system into the category of security service, need to be preceded prior to its introduction secondly, the traffic inducement security is the institution which can contribute to the improvement of traffic safety, and also internalizing social cost. therefore, it needs to be equipped with the new qualification such as the instruction with the standardized traffic safety map, instruction system, curriculum and the publication of teaching materials. thirdly, the education for the guard should be proceeded with dividing academic and technical ones with specific curriculum. At the fourth, the securement of the venue for the driving training, the determination on technical instruction contents and the training professional instructor needs for the method of administration. In addition, the efforts on the overal standardization of traffic inducement security is necessary, and it also requires constant collaboration among private security industry, academia, professionals, relavant research institutes, etc. At the last but the least, henceforth it is prerequisite that the networking system with a diverse array of associated entities due to its social ripple effect and job creation effect.

  • PDF

Assessment of Quantitative Analysis Methods for Lung F-18-Fluorodeoxyglucose PET (폐 종양 FDG PET 영상의 다양한 추적자 역학 분석 방법 개발과 유용성 고찰)

  • Kim, Joon-Young;Choi, Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Yong-Jin;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.332-343
    • /
    • 1998
  • Purpose: The purpose of this study was to assess the diagnostic accuracy of various quantitation methods using F-18-fluorodeoxyglucose (FDG) in patients with malignant or benign lung lesion. Materials and Methods: 22 patients (13 malignant including 5 bronchoalverolar cell cancer; 9 benign lesions including 1 hamartoma and 8 active inflammation) were studied after overnight fasting. We performed dynamic PET imaging for 56 min after injection of 370 MBq (10 mCi) of FDG. Standardized uptake values normalized to patient's body weight and plasma glucose concentration (SUVglu) were calculated. The uptake rate constant of FDG and glucose metabolic rate were quantified using Patlak graphical analysis (Kpat and MRpat), three compartment-five parameter model (K5p, MR5p), and six parameter model taking into account heterogeneity of tumor tissue (K6p, MR6p). Areas under receiver operating characteristic curves (ROC) were calculated for each method. Results: There was no significant difference of rate constant or glucose metabolic rate measured by various quantitation methods between malignant and benign lesions. The area under ROC curve were 0.73 for SUVglu, 0.66 for Kpat, 0.77 for MRpat, 0.71 for K5p, 0.73 for MR5p, 0.70 for K6p, and 0.78 for MR6p. No significant difference of area under the ROC curve between these methods was observed except the area between Kpat vs. MRpat (p<0.05). Conclusion: Quantitative methods did not improve diagnostic accuracy in comparison with nonkinetic methods. However, the clinical utility of these methods needs to be evaluated further in patients with low pretest likelihood of active inflammation or bronchoalveolar cell carcinoma.

  • PDF

Usefulness of F-18 FDG PET/CT in Adrenal Incidentaloma: Differential Diagnosis of Adrenal Metastasis in Oncologic Patients (부신 우연종에서 F-18 FDG PET/CT의 유용성: 악성 종양 환자에서 부신 전이의 감별진단)

  • Lee, Hong-Je;Song, Bong-Il;Kang, Sung-Min;Jeong, Shin-Young;Seo, Ji-Hyoung;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.421-428
    • /
    • 2009
  • Purpose: We have evaluated characteristics of adrenal masses incidentally observed in nonenhanced F-18 FDG PET/CT of the oncologic patients and the diagnostic ability of F-18 FDG PET/CT to differentiate malignant from benign adrenal masses. Materials and Methods: Between Mar 2005 and Aug 2008, 75 oncologic patients (46 men, 29 women; mean age, $60.8{\pm}10.2$ years; range, 35-87 years) with 89 adrenal masses incidentally found in PET/CT were enrolled in this study. For quantitative analysis, size (cm), Hounsfield unit (HU), maximum standardized uptake value (SUVmax), SUVratio of all 89 adrenal masses were measured. SUVmax of the adrenal mass divided by SUVliver, which is SUVmax of the segment 8, was defined as SUVratio. The final diagnosis of adrenal masses was based on pathologic confirmation, radiologic evaluation (HU<0 : benign), and clinical decision. Results: Size, HU, SUVmax, and SUVratio were all significantly different between benign and malignant adrenal masses.(P < 0.05) And, SUVratio was the most accurate parameter. A cut-off value of 1.0 for SUVratio provided 90.9% sensitivity and 75.6% specificity. In small adrenal masses (1.5 cm or less), only SUVratio had statistically significant difference between benign and malignant adrenal masses. Similarly a cut-off value of 1.0 for SUVratio provided 80.0% sensitivity and 86.4% specificity. Conclusion: F-18 FDG PET/CT can offer more accurate information with quantitative analysis in differentiating malignant from benign adrenal masses incidentally observed in oncologic patients, compared to nonenhanced CT.

Different $^{18}$F-FDG Uptake According to Tumor location and Morphology of Cholangiocarcinoma and Its Clinical Implication (담관암의 위치와 형태에 따른 $^{18}$F-FDG 섭취량의 차이와 임상적 의의)

  • Lee, Won-Seok;Lee, Yoon-Jae;Lim, Seok-Tae;Sohn, Myung-Hee;Lee, Seung-Ok
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.317-322
    • /
    • 2009
  • Purpose: $^{18}$F-flurodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of $^{18}$F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. Materials and Methods: From April 2005 to May 2008, eighty two patients (M:F = 55:27, age 66.2$\pm$9.6 yrs) with CC underwent $^{18}$F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV$_{max}$) was obtained from the primary tumor. The difference of SUV$_{max}$ according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Results: Overall sensitivity of PET scan was 81.7% in CC. SUV$_{max}$ on PET scan in intrahepatic CC was significantly higher compared to extrahepatic CC. In extrahepatic CC, polypoid type showed significantly higher SUV$_{max}$ compared to scirrhous type. Conclusion: $^{18}$F-FDG PET may have a significant impact on clinical decision-making and on the management of intrahepatic cholangiocarcinoma. And it is related to the shape of the tumor and the sensitivity of detection is higher in the mass-forming type than in the scirrhous type.

The Research on scheme for revitalization of Conversion into World Geodetic Reference System (세계측지계 전환 활성화를 위한 방안 연구)

  • Sohn, Duk-Jae;Lee, Hyun-Jik;Yu, Young-Geol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.3
    • /
    • pp.311-321
    • /
    • 2009
  • The Nation Geodetic Reference System which presents a consistent location standard used in creating a map or developing national land is defined and managed by the law in a nation. Each nation had used its own geodetic system created by astronomical surveying until recently, when Geodetic Reference System(World Geodetic Reference System) has been developed and used to progress in space and satellite geodetic technologies. Korea also amended its geodetic law in December 2001, converting its national geodetic system whose reference an oval figure is Bessel ellipsoid into the World Geodetic Reference System which uses GRS80 ellipsoid as reference ellipsoid. Accordingly, the National Geography Information Institute improved law and systems related to the change for the effective conversion from its national geodetic system into the World Geodetic Reference System. In addition National geographic information institute of the results of various studies is drawn to the World Geodetic Reference System for switching technology-met some of the institutional foundation Despite of accordance with formalities, National geographic information institute, Ministry of Land, Transport and Maritime Affairs and some local government of the World Geodetic Reference System, and local government has or has not spread in public institutions. Therefore, in order to promote the switch to the World Geodetic Reference System, it is required to analyze current technical and institutional problems and obstacles of the switch to the World Geodetic Reference System and to present the resolutions and to establish policy to achieve them. Accordingly, for the promotion of the switch to the World Geodetic Reference System, this study analyzed the results of previous studies, the current state of the switch to the World Geodetic Reference System and the problems of the switch, and then offered technological and institutional supplements. Furthermore, it standardized the subject and type of the conversion, defined the scope of the tasks of the National Geographic Information Institute and its related organizations, and presented the policy direction for the overall use of the World Geodetic Reference System by 2010.

A Comparative Study of the Detectable Methods of Residual Oxytetracyeline in Muscle of Flounder (Paralichthys olivaceus) with Simplified Screening Test (넙치 근육중 잔류 옥시테트라싸이클린의 간이스크리닝 검출방법 비교연구)

  • Jung, Sung-Hee;Kim, Jin-Woo
    • Journal of fish pathology
    • /
    • v.11 no.1
    • /
    • pp.77-81
    • /
    • 1998
  • By standardized method, Bacillus subtilis BGA, Bacillus cereus var. mycoides ATCC 11778, and Micrococcus luteus ATCC 9341 were seeded on the muller hinton agar (Difco) plate, and pH was adjusted to 6.0, 7.2, and 8.0. Five agar plates, B. subtilis (pH 6.0), B. cereus (pH 6.0), B. subtilis (pH 7.2), B. subtilis (pH 8.0), and M. luteus (pH 8.0), were employed as test plates of modified EEC 4-plate method. Oxytetracycline (OTC) with a diet was orally administered to flounder, Paralichthys olivaceus, at 100 mg/kg once a day. After oral administration, modified EEC 4-plate method by the three screening test using muscle-direct, extraction-disk and direct-disk methods was conducted for 3 fish at 1, 3, 5, 10, 15, 20, 25 and 30 days. Muscle-direct treatment of B. subtilis (pH 6.0) was found to be dubious positive (${\pm}$) at the 1st day after the administration; thereafter, it was found to be negative to the last day of the experiment. Extraction-disk and direct-disk treatment of B. subtilis (pH 6.0) were found to be negative from the 1st day to the last day after the administration. B. subtilis (pH 7.2), B. subtilis (pH 8.0), and M. luteus (pH 8.0) by the three screening tests, were found to be negative all the way after the administration. On the other hand, B. cereus (pH 6.0) by the three screening tests was clearly found to be positive for the first 15 days after the administration, and then muscle-direct and direct-disk treatment of B. cereus (pH 6.0) were found to be dubious positive at 20th days after the administration. However extraction-disk treatment of B. cereus (pH 6.0) was clearly found to be negative at the same stage; thereafter, the three screening tests of B. cereus (pH 6.0) were found negative to the last of the experiment. These findings showed that to have equal sensitivity to those determination for the residual detection of OTC, and also confirmed that B. cereus was effective test organism for the monitoring of OTC.

  • PDF