• Title/Summary/Keyword: standard of diagnosis

Search Result 1,197, Processing Time 0.028 seconds

A Study for the Calculation of the Surface Chloride on the concrete by using Colorimetric method (비색판별법을 이용한 콘크리트의 표면염화물량 산정)

  • 이진우;이문환;서치호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.815-820
    • /
    • 2001
  • This study is to set a new standard for using of the colorimetric method through grasping the character of the colorimetric method, and measuring the chloride concentration at the place of the change of color. Also, to predict chloride concentration around rebar and time reaching limit chloride concentration through measuring the chloride concentration of concrete surface by the colorimetric method and this study presents the new program of concrete degradation and diagnosis of the durability by salt damage. First the use of the colorimetric method was examinated, second the chloride concentration through slicing concrete submerged in artificial seawater for 6 months was measured. And the chloride concentration at the place of the change of color was calculated by using colorimetric method. Finally, the cloride concentration of the concrete surface was calculated.

  • PDF

Esophageal pH and Combined Impedance-pH Monitoring in Children

  • Shin, Myung Seok
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.17 no.1
    • /
    • pp.13-22
    • /
    • 2014
  • Esophageal pH monitoring is considered the gold standard for the diagnosis of gastroesophageal reflux disease because of the normal ranges across the pediatric age range. However, this method can only detect acid reflux. Multichannel intraluminal impedance-pH (MII-pH) monitoring has recently been used for the detection of bolus reflux in infants and children. This method allows for the detection of liquid, gas or mixed reflux in addition to acid, weakly acidic or weakly alkaline reflux. MII-pH monitoring can record the direction of flow and the height of reflux, which are useful parameters to identify an association between symptoms and reflux. However, the technique is limited by its high cost and the lack of normative data of MII-pH in the pediatric population. Despite certain limitations, MII-pH monitoring will become more common and gradually replace pH monitoring in the future, because pH monitoring is part of MII-pH.

BK virus-associated hemorrhagic cystitis after pediatric stem cell transplantation

  • Han, Seung Beom;Cho, Bin;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.12
    • /
    • pp.514-519
    • /
    • 2014
  • Hemorrhagic cystitis is a common stem cell transplantation-related complication. The incidence of early-onset hemorrhagic cystitis, which is related to the pretransplant conditioning regimen, has decreased with the concomitant use of mesna and hyperhydration. However, late-onset hemorrhagic cystitis, which is usually caused by the BK virus, continues to develop. Although the BK virus is the most common pathogenic microorganism of poststem cell transplantation late-onset hemorrhagic cystitis, pediatricians outside the hemato-oncology and nephrology specialties tend to be unfamiliar with hemorrhagic cystitis and the BK virus. Moreover, no standard guidelines for the early diagnosis and treatment of BK virus-associated hemorrhagic cystitis after stem cell transplantation have been established. Here, we briefly introduce poststem cell transplantation BK virus-associated hemorrhagic cystitis.

Data Quality of Childhood Cancer in Khon Kaen, Thailand, 1990-2007

  • Suwanrungruang, Krittika;Kamsa-ard, Supot;Wiangnon, Surapon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7985-7987
    • /
    • 2014
  • Introduction: Khon Kaen Cancer Registry (KKCR) was established in 1984. KKCR aims to collect all cancer cases in Khon Kaen Province. The poorly qualified data may lead to distort the cancer burden and misinterpretation of policy maker. Objective: To assess data quality in childhood cancer between 1990 and 2007 in Khon Kaen Province, Thailand. Materials and Methods: Data of childhood cancer cases aged less than 20 years diagnosed during 1990-2007 were retrieved from the population-based data set of KKCR. All childhood cancer data were verified before data entry. Internal consistency, percentage of morphological verification (MV%) and cancer cased of the basis of diagnosis by death certificate only (DCO%) were evaluated. The age-adjusted rate (ASR) was calculated by standard method. Results: The data of childhood cancer from KKCR is acceptably qualified which reflects the quality of the whole registration.

A Case Report of Symptomatic Character and Diagnosis of Fibromyalgia (섬유근통(fibromyalgia)의 병태와 진단을 위한 임상 1례 보고)

  • Jeong, Tae-Young;Cho, Jung-Hyo;Park, Bong-Ky;Son, Chang-Gue
    • The Journal of Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.162-168
    • /
    • 2009
  • Objective: This report aimed to study fibromyalgia's diagnostic criteria, differential diagnoses and its pathology from the viewpoint of oriental medicine. Method: We observed and diagnosed a female patient who complained of prolonged whole body pain, even several times hospitalized for treatment. Result: The patient's symptoms correspond with fibromyalgia and we ruled out other suspected diseases. Conclusion: Fibromyalgia is prone to be misdiagnosed because the patient has complicated symptoms such as various pains and chronic fatigue as well as depression unexplained by medical tests. Furthermore, the symptoms often never disappear completely, although it isn't progressive or life-threatening, and can be improved. So accumulation of data and analysis from the viewpoint of oriental medicine is necessary for development of oriental medical standard treatment.

  • PDF

In-field Evaluation of Structural Strength and Reliability Using Advanced Indentation System (Advanced Indentation System을 이용한 현장에서의 구조강도 건전성 평가)

  • Choi, Yeol;Son, Dong-Il;Jang, Jae-Il;Kwon, Dong-Il
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.230-237
    • /
    • 2001
  • For the structural integrity of large and complex structures such as railway vehicle, the in-field diagnosis of mechanical properties of the structures is needed, and especially, the mechanical characteristics of the weldment must be carefully evaluated. But, conventional standard testing methods having destructive procedures are not applicable to in-field assessment of mechanical property variations within weldment because they needs the limitations of specimen size and geometry. In this paper, to overcome this problems, the advanced indentation technique (AIS) is introduced for simple and non-destructive/in-field testing of weldment of industrial structures. This test measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation and fracture. First of all, flow properties such as yield strength, tensile strength and work hardening index can be evaluated through the analysis of the deformation behavior beneath the spherical indenter. Additionally, case studies of advanced indentation techniques are introduced.

  • PDF

System Integration for the Operation of Unmanned Audio Center based on AoIP

  • Lee, Jaeho;Hamacher, Alaric;Kwon, Soonchul;Lee, Seunghyun
    • International journal of advanced smart convergence
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Recently, the development of the information communication industry has made many changes in the industrial acoustic industry. Especially, it has a great influence on the change of system and equipment of acoustic system. Analog equipment is changing to digital equipment, and integrated control equipment makes it easier to operate and manage the sound system. However, the integrated control system currently on the market is only controllable for some devices. In this paper, we propose a new AoIP - based system configuration method, which enables the operation status monitoring, unmanned operation and self - diagnosis of equipment. As a result of the study, it is confirmed that the proposed system can be operated, monitored, and self - diagnosed at remote sites. It is expected that an AoIP- based sound system will be the industry standard in the future.

Pediatric Obstructive Sleep Apnea Syndrome (소아 폐쇄성수면무호흡증후군)

  • Lee, Seung-Hoon;Choi, Ji-Ho
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.2
    • /
    • pp.98-104
    • /
    • 2005
  • Approximately 1% to 3% of all children have obstructive sleep apnea syndrome (OSAS). OSAS in children can lead to a variety of symptoms and sequalae; impairment of development and quality of life, behavioral and personality disturbance, learning problem, cor pulmonale and hypertension. Diagnosis and treatment of OASA for children are different from those for adults in many respects. Adenotonsillar hypertrophy is major cause of childhood OSAS. Overnight polysomnography in a sleep laboratory is the gold standard for diagnosing childhood OSAS. However, because full polysomnography in children may be difficult to obtain, expensive, and inconvenient, other methods to diagnose OSAS have been investigated. Adenotonsillectomy is the most common surgical treatment of childhood OSAS. But if residual symptoms remained after adenotonsillectomy, it should be considered to additional treatment such as weight control, sleep positional change, and continuous positive airway pressure (CPAP).

  • PDF

Diagnosis of Plasma Equipment using Neural Network and Impedance Match Monitoring

  • Byungwhan Kim
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.120-124
    • /
    • 2002
  • A new methodology is presented to diagnose faults in equipment plasma. This is accomplished by using neural networks as a pattern recognizer of radio frequency (rf) impedance match data. Using a match monitor system, the match data were collected. The monitor system consisted mainly of a multifunction board and a signal flow diagram coded by Visual Designer. Plasma anomaly was effectively represented by electrical match positions. Twenty sets of fault-symptom patterns were experimentally simulated with variations in process factors, which include rf source power, pressure, Ar, and $O_$2 flow rates. As an input to neural networks, two means and standard deviations of positions were used as well as a reflected power. Diagnostic accuracy was measured as a function of training factors, which include the number of hidden neurons, the magnitude of initial weights, and two gradients of neuron activation functions. The accuracy was the most sensitive to the number of hidden neurons. Interaction effects on the accuracy were also examined by performing a 2$^$4 full factorial experiment. The experiments were performed on multipole inductively coupled plasma equipment.

  • PDF

New evolution of cone-beam computed tomography in dentistry: Combining digital technologies

  • Jain, Supreet;Choudhary, Kartik;Nagi, Ravleen;Shukla, Stuti;Kaur, Navneet;Grover, Deepak
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.179-190
    • /
    • 2019
  • Panoramic radiographs and computed tomography (CT) play a paramount role in the accurate diagnosis, treatment planning, and prognostic evaluation of various complex dental pathologies. The advent of cone-beam computed tomography (CBCT) has revolutionized the practice of dentistry, and this technique is now considered the gold standard for imaging the oral and maxillofacial area due to its numerous advantages, including reductions in exposure time, radiation dose, and cost in comparison to other imaging modalities. This review highlights the broad use of CBCT in the dentomaxillofacial region, and also focuses on future software advancements that can further optimize CBCT imaging.