• Title/Summary/Keyword: standard for reinforcing steel

Search Result 34, Processing Time 0.029 seconds

Evaluation of Minimum Extensibility Standard Requirements for Steel Reinforcement (철근 최소 연신율 규격에 대한 평가)

  • Lee, Jae-Hoon;Kim, Dong-Hyun;Choi, Jin-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.559-567
    • /
    • 2011
  • Recently, many researches on high strength reinforcing steel have been conducted to construct optimum reinforced concrete structures. However, the studies have shown that high strength steel shows less elongation capacity than normal strength steel. Therefore, high strength reinforcing steel may not satisfy the minimum elongation requirement of current standards. Moreover, elongation measurements may be not standardized ones since each standard has its own requirements for minimum elongation and gage length. Therefore, the standards for reinforcing steel testing must be investigated to verify the validity of Korean Standard D 3504. This research aimed to compare the requirements for minimum elongation and gage length of the Korean, American, Japanese, European, and ISO Standards. Then, the study further investigated accuracy of the standards by tensile test of reinforcing steel. The study results showed that the Korean Standard has the strictest requirement. Based on the study results, the authors proposed modified minimum elongation requirements for general reinforcing steel and new requirements for seismic reinforcing steel.

A Proposal of Minimum Steel Ratio Considering Size Effect for Flexural Reinforced Concrete Member (크기효과가 고려된 철근콘크리트 휨 부재의 최소철근비 제안)

  • Yoo, Sung-Won;Her, Yoon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.128-136
    • /
    • 2010
  • In according with concrete structural design standard, it is common designing flexure reinforcement concrete to induce tension failure. So reinforcing ratio is limited to inducing tension failure. And maximum reinforcing ratio is regulated to protecting concrete compression strength caused by over reinforced building. Minimum reinforcing ratio is also limited in designing standard to protecting brittle failure as extremely using less reinforcing bar. But in minimum reinforcing ratio it is extremely conservative or it is sometimes impossible to induce stable tension-failure because they are depending on yield failure and experienced method and concrete designing standard strength. Therefore the purpose of the present paper is to evaluate the flexural behavior of minimum steel ratio of reinforced concrete of beams and to propose the guide-line of equation of minimum steel ratio by performing static flexural test of 16 beams according to size effect, number of steel, yielding stress of steel, and concrete compressive strength which are presumed effective variables. From experimental results, the equation of minimum steel ratio was newly proposed considered size effect.

An Experimental Study on the Bond Characteristics of Glass Fiber Reinforced Polymer Rebar (GFRP Rebar의 부착성능에 관한 실험적 연구)

  • Park Ji-Sun;You Young-Chan;Park Young-Hwan;Choi Ki-Sun;Kim Hyeong-Yeol;Kim Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.124-127
    • /
    • 2004
  • This study is to investigate the bond characteristics of glass fiber reinforced polymer(GFRP) reinforcing bars in concrete by pullout test experimentally. Three different types of GFRP bars with different surface deformations were considered in this study. Also, standard deformed steel reinforcing bar with or without epoxy-coating were included for the comparisons of bond strength. All test procedures including specimens preparation, test apparatus and measuring devices were made according to the recommendation of CSA(Canadian Standards Association) Standard S806-02. From the test results, it was found that small surface indentations contributed to increase the bond strength of GFRP bar significantly. Based on the limited test results till now, the bond strength of GFRP bar with sand-coated deformation commercially available in foreign market is around $80\%$ of that of steel deformed bars.

  • PDF

Bond Stress-Strain Predict Model with Inner Cover Thickness of Steel Wire Used in Void Deck Plate (중공 데크플레이트에 사용된 철선의 내부피복두께에 따른 부착응력-변형률 예측모델)

  • Kim, Hee-Hyeon;Choi, Chang-Sik
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.41-51
    • /
    • 2018
  • In case of evaluating the bond stress of a void deck plate using a wire steel, there is no standard formula considering both the influence on the void and the type of the reinforcing bar. Therefore we proposed a model equation considered the bond characteristics of the void deck plate. A total of 46 specimens was carried out a direct pull-out test and the test variables were the presence of a void body, type of reinforcing bar, the inner cover thickness according to the location of reinforcing bars and bond region. As a result of the comparison between the steel bar and steel wire, the bond stress of the steel wire with the relative rib area of 0.071 is 4.5 ~ 28.58% lower than that of the steel bar with 0.092 and the bond stress reduction rate increases when the inner cover thickness is insufficient. In the case of the inner cover thickness of $1.7d_b$ and $2.7d_b$, the bond stress was reduced to 48.7 ~ 68.4%. In the inner cover thickness was $4.9d_b$ and $5.2d_b$, the bond stresses were equivalent to those of the solid specimens. It was confirmed that the average bond stress and strain were affected by the inner cover thickness. Therefore the predicted model for one module of the void deck plate is proposed and verified by considering the bond characteristics of the void deck plate.

Test Method of Determination of Chloride content by JCI Standards in Cement Paste (JCI 규준에 따른 시멘트페이스트내 염화물량 측정)

  • 문소현;윤성진;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1233-1237
    • /
    • 2000
  • In this study, we measured and assay the analysis of chloride ion in cement hydration by the standard method of JCI and understand the mutual relation between added contents and result. The purpose of this research is to provide fundamental information for the deterioration of the reinforcing concrete on account of steel of reinforced steel to repress.

Flexural Behavior of Fiber Reinforced Concrete Beams with Hybrid Double-layer Reinforcing Bars (이중 보강근을 가지는 FRC 보의 휨성능)

  • Kim, Seongeun;Kim, Seunghun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.199-207
    • /
    • 2018
  • Experimental programs were performed to evaluate the flexural performance of fiber reinforced concrete(FRC) beams using a hybrid double-layer arrangement of steel bars and fiber reinforced polymer(FRP) bars or using FRP bars only. A total of seven beam specimens were produced with type of tensile reinforcing bar(CFRP bar, GFRP bar, steel bar) and the poly vinyl alcohol(PVA) fiber mixing ratio(0.5%, 0%) as variable. An analysis method for predicting the flexural behaviors of FRC beams with hybrid arrangement of heterogeneous reinforcing bars through finite element analysis was proposed and verified. In case of the specimens with the double-layer reinforcing bars, the test results showed that the first cracking load of specimen with a double-layer arrangement of steel bars was greater by 26-34% than specimens with a hybrid double-layer arrangement of steel and FRP bars. In maximum flexural strengths, the specimen that used CFRP bars as bottom tensile reinforcing bar showed the greatest strength among the specimens with the double-layer reinforcing bars. When the maximum moment value obtained through experiments was compared with that obtained through analysis, the ratio was 1.2 on average, the standard deviation was 0.085, and the maximum error rate was 22% or less. Based on these results, the finite element analysis model proposed in this study can effectively simulate the actual behavior of the beams with hybrid double-layer reinforcing bars.

Post-peak response analysis of SFRC columns including spalling and buckling

  • Dhakal, Rajesh P.
    • Structural Engineering and Mechanics
    • /
    • v.22 no.3
    • /
    • pp.311-330
    • /
    • 2006
  • Standard compression tests of steel fiber reinforced concrete (SFRC) cylinders are conducted to formulate compressive stress versus compressive strain relationship of SFRC. Axial pullout tests of SFRC specimens are also conducted to explore its tensile stress strain relationship. Cover concrete spalling and reinforcement buckling models developed originally for normal reinforced concrete are modified to extend their application to SFRC. Thus obtained monotonic material models of concrete and reinforcing bars in SFRC members are combined with unloading/reloading loops used in the cyclic models of concrete and reinforcing bars in normal reinforced concrete. The resulting path-dependent cyclic material models are then incorporated in a finite-element based fiber analysis program. The applicability of these models at member level is verified by simulating cyclic lateral loading tests of SFRC columns under constant axial compression. The analysis using the proposed SFRC models yield results that are much closer to the experimental results than the analytical results obtained using the normal reinforced concrete models are.

Experimental and analytical behaviour of cogged bars within concrete filled circular tubes

  • Pokharel, Tilak;Yao, Huang;Goldsworthy, Helen M.;Gad, Emad F.
    • Steel and Composite Structures
    • /
    • v.20 no.5
    • /
    • pp.1067-1085
    • /
    • 2016
  • Recent research on steel moment-resisting connection between steel beams and concrete filled steel tubes has shown that there are considerable advantages to be obtained by anchoring the connection to the concrete infill within the tube using anchors in blind bolts. In the research reported here, extensive experimental tests and numerical analyses have been performed to study the anchorage behaviour of cogged deformed reinforcing bars within concrete filled circular steel tubes. This data in essential knowledge for the design of the steel connections that use anchored blind bolts, both for strength and stiffness. A series of pull-out tests were conducted using steel tubes with different diameter to thickness ratios under monotonic and cyclic loading. Both hoop strains and longitudinal strains in the tubes were measured together with applied load and slip. Various lead-in lengths before the bend and length of tailed extension after the bend were examined. These dimensions were limited by the dimensions of the steel tube and did not meet the requirements for "standard" cogs as specified in concrete standards such as AS 3600 and ACI 318. Nevertheless, all of the tested specimens failed by bar fracture outside the steel tubes. A comprehensive 3D Finite Element model was developed to simulate the pull-out tests. The FE model took into account material nonlinearities, deformations in reinforcing bars and interactions between different surfaces. The FE results were found to be in good agreement with experimental results. This model was then used to conduct parametric studies to investigate the influence of the confinement provided by the steel tube on the infilled concrete.

A Study on Relations between Shape Factor and Temperature History of Steel of Composit Beam in Standard Fire under Same Thickness Condition of Spray-type Fire Resistant Materials (동일 내화뿜칠 피복조건에서 표준화재에 노출된 합성보의 강재 온도이력 및 단면형상계수와의 관계)

  • Yeo, In-Hwan;Cho, Kyung-Suk;Cho, Bum-Yean
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.72-77
    • /
    • 2012
  • When the concrete and steel combined composite beam is exposed to high temperature, concrete could delay temperature rising of steel by covering or increase heat capacity of structural member. For becoming of structural reinforcing by unification between materials, fire resistance rate of composite beam would be higher than simple steel beam. The temperature rising of exposed steel of composite beam is directly related with section shape and exposure length of steel. In this study, fire resistant tests were carried out for composite beams and steel beam with same thickness of spray-type fire resistant materials in standard fire, and after that, temperature histories were analysed and compared with shape factor. The correlation between steel temperature and shape factor was showed very high. This result suggests that if it can be predict the comparative advantage of member by factor which cause the performance enhancement, it could be conclude that an Standard Accreditation method can be adjust to members without indivisual certifiicate of accreditation.

Development of Application Technology of High-Strength Reinforcing Bars for Nuclear Power Plant Structure : Performance Evaluation Test of the Wall (원전 구조물의 고강도 철근 적용 기술개발 : 벽체의 성능평가 실험)

  • Kim, Seok-Chul;Lim, Sang-Joon;Lee, Byung-Soo;Bang, Chang-Joon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.201-202
    • /
    • 2012
  • Recently, High-Strength steel reinforcement has been studied throughout the internal and external. One of the advantages using High-Strength steel reinforcement in construction is the economic effect due to the decreasing of its quantity. Also, another good effect is the increases of workability by reason of reducing the congestion. But, realistically it is not used in nuclear power plant construction site because of the restriction of design standard. The purpose of this report secures the reliability and changes the code through the performance evaluation test of the wall using the high-strength steel reinforcement in nuclear power plant.

  • PDF