• Title/Summary/Keyword: standard

Search Result 46,834, Processing Time 0.087 seconds

Descriptive Study for Sonographic Morphology of the 1st Facet of Subscapularis Footprint (견갑하건 부착부의 제1부착면에 대한 초음파 소견의 기술적 연구)

  • Sohn, Hoon-Sang;Wi, Chan Kuk;Shon, Min Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.343-352
    • /
    • 2019
  • Purpose: The purpose of this study was to document the sonographic morphology of the subscapularis footprint, particularly the 1st facet, of the non-pathologic subscapularis tendon and footprint, and analyze the correlation between the size of the 1st facet and the demographic variables. Materials and Methods: Between March 2015 and December 2017, retrospectively data analysis was performed for the ultrasound (US) scans of 115 consecutive shoulder (mean age 53.4 years, range 23-74 years) with non-pathologic subscapularis tendon and footprint. The sonographic findings of the 1st facet of the subscapularis footprint was a very unique, flat, broad, and plane angle in the upward direction, which were distinguished from the other facets. On US, the transverse (medio-lateral) and longitudinal (superior-inferior) length of the 1st facet on axis of the humerus shaft were recorded. The demographic variables, including age, site, body height, weight, body mass index (BMI), and arm length, were reviewed. Results: On US, the mean transverse length of the 1st facet was 12.75 mm (range 10.54-14.50 mm, standard deviation [SD] 0.712) and the mean longitudinal length was 12.22 mm (range 9.20-13.30 mm, SD 0.888). The transverse and longitudinal length of the size of the 1st facet were significantly greater in males than in females (p<0.001, p=0.001). Of the demographic data (body height, weight, BMI, arm length) that showed a significant positive linear correlation, the correlation with body height (transverse r=0.749, p<0.001; longitudinal r=0.642, p<0.001) showed the strongest relationship, and the correlation with the BMI was weakly related. The relationships between the size of the 1st facet to site/age were not statistically significant or appeared to have no linear correlation. Conclusion: The structural and morphologic features of the 1st facet of the subscapularis footprint on the US were identified. This will provide anatomic knowledge of an US examination for subscapularis tendon pathology.

Evaluation of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria (LG AdvansureTM Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성)

  • Lee, Hye Jin;Kim, Ha Nui;Yoo, Byong Joon;Kim, Jang Su;Kim, Myong Han;Lim, Chae Seung;Lee, Kap No
    • Laboratory Medicine Online
    • /
    • v.1 no.2
    • /
    • pp.100-104
    • /
    • 2011
  • Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG AdvansureTM Malaria P.f./P.v. real-time QPCR (LG life sciences, Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection, N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG AdvansureTM Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG AdvansureTM Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG AdvansureTM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.

A Study on Image Copyright Archive Model for Museums (미술관 이미지저작권 아카이브 모델 연구)

  • Nam, Hyun Woo;Jeong, Seong In
    • Korea Science and Art Forum
    • /
    • v.23
    • /
    • pp.111-122
    • /
    • 2016
  • The purpose of this multi-disciplinary convergent study is to establish Image Copyright Archive Model for Museums to protect image copyright and vitalize the use of images out of necessity of research and development on copyright services over the life cycle of art contents created by the museums and out of the necessity to vitalize distribution market of image copyright contents in creative industry and to formulate management system of copyright services. This study made various suggestions for enhancement of transparency and efficiency of art contents ecosystem through vitalization of use and recycling of image copyright materials by proposing standard system for calculation, distribution, settlement and monitoring of copyright royalty of 1,000 domestic museums, galleries and exhibit halls. First, this study proposed contents and structure design of image copyright archive model and, by proposing art contents distribution service platform for prototype simulation, execution simulation and model operation simulation, established art contents copyright royalty process model. As billing system and technological development for image contents are still in incipient stage, this study used the existing contents billing framework as basic model for the development of billing technology for distribution of museum collections and artworks and automatic division and calculation engine for copyright royalty. Ultimately, study suggested image copyright archive model which can be used by artists, curators and distributors. In business strategy, study suggested niche market penetration of museum image copyright archive model. In sales expansion strategy, study established a business model in which effective process of image transaction can be conducted in the form of B2B, B2G, B2C and C2B through flexible connection of museum archive system and controllable management of image copyright materials can be possible. This study is expected to minimize disputes between copyright holder of artwork images and their owners and enhance manageability of copyrighted artworks through prevention of such disputes and provision of information on distribution and utilization of art contents (of collections and new creations) owned by the museums. In addition, by providing a guideline for archives of collections of museums and new creations, this study is expected to increase registration of image copyright and to make various convergent businesses possible such as billing, division and settlement of copyright royalty for image copyright distribution service.

Physicochemical Characteristics and Skin Absorption of Transfersomes Containing Centella asiatica Extract According to Edge Activators (Edge Activator 에 따른 병풀추출물 함유 트렌스퍼좀의 물리화학적 특성과 피부흡수)

  • Eun-hee Lee;Kyung-Sup Yoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.2
    • /
    • pp.147-157
    • /
    • 2023
  • Centella asiatica extract is widely used as a raw material for cosmetics due to its various effects, but it is difficult to expect penetration into the skin due to its high molecular weight and low solubility. In order to solve these problems, lipid-based liposomes of various types were developed to increase skin absorption. Therefore, in this study, we tried to increase the skin absorption rate by preparing transfersomes using surfactants as edge activators in existing liposomes. Liposome and transfersomes containing Span 80 and Tween 20, 60, 80, and 85, respectively, were prepared using a high-pressure homogenizer, and we evaluated the particle size, polydispersity index, zeta potential, and skin absorption rate. As a result, there was almost no change in the physical properties of particle size, polydispersity index and zeta potential from 25 ℃ to 60 d, and the particle size of transfersomes containing Tween 20, 60, and 80 increased after 60 d at 45 ℃. Madecassoside, main substances of the Centella asiatica extract was used as an standard and madecassoside was measured and calculated when measuring the skin absorption rate using Franz diffusion cells. As a result, formulations containing Tween 20 were the most, whereas formulations containing Span 80 were the least. According to the skin absorption coefficient (Kp) value, all formulations showed 'very fast', and the absorption rate was similar or greater than that of liposomes, except for formulations containing Span 80. Through this, it was confirmed that the larger the HLB value of the nonionic surfactant, the smaller the particle size of the transfersome, and the increased skin absorption rate due to the increased flexibility of the vesicle membrane. Through this study, transfersome using surfactant as an edge activator can be expected to solve local skin problems not only as a cosmetic raw material or product, but also by increasing skin absorption.

A Study on the Application of IUCN Global Ecosystem Typology Using Land Cover Map in Korea (토지피복지도를 활용한 IUCN 생태계유형분류 국내 적용)

  • Hee-Jung Sohn;Su-Yeon Won;Jeong-Eun Jeon;Eun-Hee Park;Do-Hee Kim;Sang-Hak Han;Young-Keun Song
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.3
    • /
    • pp.209-220
    • /
    • 2023
  • Over the past few centuries, widespread changes to natural ecosystems caused by human activities have severely threatened biodiversity worldwide. Understanding changes in ecosystems is essential to identifying and managing threats to biodiversity. In line with this need, the IUCN Council formed the IUCN Global Ecosystem Typology (GET) in 2019, taking into account the functions and types of ecosystems. The IUCN provides maps of 10 ecosystem groups and 108 ecological functional groups (EFGs) on a global scale. According to the type classification of IUCN GET ecosystems, Korea's ecosystem is classified into 8 types of Realm (level 1), 18 types of Biome (level 2), and 41 types of Group (level 3). GETs provided by IUCN have low resolution and often do not match the actual land status because it was produced globally. This study aimed to increase the accuracy of Korean IUCN GET type classification by using land cover maps and producing maps that reflected the actual situation. To this end, we ① reviewed the Korean GET data system provided by IUCN GET and ② compared and analyzed it with the current situation in Korea. We evaluated the limitations and usability of the GET through the process and then ③ classified Korea's new Get type reflecting the current situation in Korea by using the national data as much as possible. This study classified Korean GETs into 25 types by using land cover maps and existing national data (Territorial realm: 9, Freshwater: 9, Marine-territorial: 5, Terrestrial-freshwater: 1, and Marine-freshwater-territorial: 1). Compared to the existing map, "F3.2 Constructed lacustrine wetlands", "F3.3 Rice paddies", "F3.4 Freshwater aquafarms", and "T7.3 Plantations" showed the largest area reduction in the modified Korean GET. The area of "T2.2 Temperate Forests" showed the largest area increase, and the "MFT1.3 Coastal saltmarshes and reedbeds" and "F2.2 Small permanent freshwater lakes" types also showed an increase in GET area after modification. Through this process, the existing map, in which the sum of all EFGs in the existing GET accounted for 8.33 times the national area, was modified so that the total sum becomes 1.22 times the national area using the land cover map. This study confirmed that the existing EFG, which had small differences by type and low accuracy, was improved and corrected. This study is significant in that it produced a GET map of Korea that met the GET standard using data reflecting the field conditions. 

Comparison of Dissolved Ammonium Analytical Method in Seawater: Spetrophotometry and Fluorometry (해수 중 용존 암모늄 분석방법 비교: 분광광도법과 형광법)

  • SON, PURENA;PARK, JOONSEONG;RHO, TAEKEUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.25 no.4
    • /
    • pp.81-96
    • /
    • 2020
  • Berthlot's reaction spectrophotometric method is generally used for the analysis of dissolved ammonium in seawater, but in recent years, a fluorescence method using an orthophthaldialdehyde-sulfite (OPA) fluorescent reagent is actively used internationally. In this study, we investigated the effects of the detection limit between the analysis methods, the reagent refractive index inherent in the spectrophotometric method, and the use of different calibration curves to understand the cause of the difference in dissolved ammonium concentration (about 0.31 𝜇M) observed in the seawater samples and a nutrient reference material between two institutions (KIOST (spectrophotometric method, one-order linear regression gradient only), Australia CSIRO (fluorescence method, quadratic formula)) conducted onboard the Australian R/V Investigator in 2017. The method detection limit (0.063 𝜇M) and the reagent refractive index background value (0.054 𝜇M) of the spectrophotometric method measured in this study could explain the difference in dissolved ammonium concentration values of the two institutes about 20% and 17%, respectively. However, when the concentration of the calibration curve of the spectrophotometric method was calculated using the same quadratic as the fluorescence method or the slope and intercept of linear regression, the difference in the dissolved ammonium concentration between the two institutions was reduced to less than the detection limit of the spectrophotometric method. Therefore, the difference in the concentration of dissolved ammonium between the two institutions, found in the nutrient reference materials and the seawater field sample during the international onboard nutrient inter-comparison experiment, may be attributed to be the effect of the different calibration curves used in the two methods rather than the effect of the difference in two analytical methods. When comparing the dissolved ammonium data from seawater samples in the future, it is recommended to pay attention to the information on the baseline, number of standard solutions, and calibration curve used in the analysis.

Estimation for Ground Air Temperature Using GEO-KOMPSAT-2A and Deep Neural Network (심층신경망과 천리안위성 2A호를 활용한 지상기온 추정에 관한 연구)

  • Taeyoon Eom;Kwangnyun Kim;Yonghan Jo;Keunyong Song;Yunjeong Lee;Yun Gon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.2
    • /
    • pp.207-221
    • /
    • 2023
  • This study suggests deep neural network models for estimating air temperature with Level 1B (L1B) datasets of GEO-KOMPSAT-2A (GK-2A). The temperature at 1.5 m above the ground impact not only daily life but also weather warnings such as cold and heat waves. There are many studies to assume the air temperature from the land surface temperature (LST) retrieved from satellites because the air temperature has a strong relationship with the LST. However, an algorithm of the LST, Level 2 output of GK-2A, works only clear sky pixels. To overcome the cloud effects, we apply a deep neural network (DNN) model to assume the air temperature with L1B calibrated for radiometric and geometrics from raw satellite data and compare the model with a linear regression model between LST and air temperature. The root mean square errors (RMSE) of the air temperature for model outputs are used to evaluate the model. The number of 95 in-situ air temperature data was 2,496,634 and the ratio of datasets paired with LST and L1B show 42.1% and 98.4%. The training years are 2020 and 2021 and 2022 is used to validate. The DNN model is designed with an input layer taking 16 channels and four hidden fully connected layers to assume an air temperature. As a result of the model using 16 bands of L1B, the DNN with RMSE 2.22℃ showed great performance than the baseline model with RMSE 3.55℃ on clear sky conditions and the total RMSE including overcast samples was 3.33℃. It is suggested that the DNN is able to overcome cloud effects. However, it showed different characteristics in seasonal and hourly analysis and needed to append solar information as inputs to make a general DNN model because the summer and winter seasons showed a low coefficient of determinations with high standard deviations.

Study on individual characterization of sweat components (개체별 땀의 성분분포에 관한 연구)

  • Choi, Mi Jung;Ha, Jaeho;Yoo, Seok;Park, Sung Woo
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.434-441
    • /
    • 2007
  • The aim of this paper is to investigate composition of fatty acids in sweat on purpose of latent fingerprint detectant developing and crime evidence searching. Fingerprint from 5 male donors (aged 29-50 years) were collected. We identified fatty acid components on sweat using methylester mixture (37species) as standard fatty acid and analyzed them by GC-FID. As donor was aged, the level of total fat was found to decrease markedly (aged 20-30 years: 56.4-72.0 %, aged 50 years : 32.4-45.4 %). We identifided 28 species fatty acid, primarilly C16:0(palmitic acid), C16:1 (palmitoleic acid), C18:1n9c(oleic acid), C18:0 (stearic acid), C14:0 (tetradecanoic acid) and all sweats were found to contain C12:0 (lauric acid), C15:0 (pentadecanoic acid), C18:2n6c (linoleic acid), C18:2n6t (linolelaidic acid), C20:0 (arachidic acid), C24:0/C20:5n3 (lignoceric acid/eicosapentaenoic acid), but with differing frequencies and at varying levels. C14:1 (myristoleic acid), C15:1 (pentadecenoic acid), C21:0 (heneicosanoic acid), C22:1n9 (erucic acid) were often observed in sample. Ratio of saturated and unsaturated fatty acid was from 0.94:1 to 2.6:1. And decrease of total fatty acids components caused by loss of saturated fatty acid and monounsaturated fatty acid. In case of sweat amino acids, we detected serine ($0-31.9{\mu}L/mL$), threonine ($0-26.2{\mu}L/mL$), glycine ($0-18.9{\mu}L/mL$) and 20-30 years old, highly protein intake ratio individuals increased (10 times) than 50 years old. We observed greatly individual characterization of amino acid compounds in sweat.

Square wave voltammetric behaviors and determinations of ranitidine·HCl in the pharmaceutical tablets (의약품 정제 중에 함유된 Ranitidine·HCl의 네모파 전압전류법 거동과 정량분석)

  • Shin, Soon Ho;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.432-438
    • /
    • 2009
  • In order to develop the analytical method for the pharmaceutical tablets containing ranitidine HCl by square wave voltammetry (SWV), $5.00{\times}10^{-5}M$ ranitidine HCl solutions prepared with phosphate buffers of various pH values were investigated by SWV. The well defined main peak due to the electrochemical reduction of $-NO_2$ in the structure of ranitidine moved towards the cathodic direction by -70 mV/pH as the pH values were increased indicating the involvement of hydrogen in its reduction. The calibration curve, the plot of peak currents (Ip) vs. concentrations of ranitidine HCl in the range between $1.00{\times}10^{-7}M$ and $1.00{\times}10^{-5}M$ showed linearity with slopes of $232,530{\mu}A/M$ (pH 6.14), $289,015{\mu}A/M$ (pH 7.07) and $232,843{\mu}A/M$ (pH 8.01). When one pharmaceutical tablet was simply dissolved in the phosphate buffer with a pH value of 6.14 and determined by standard addition method using SWV, the within-day precision study (n=4) resulted in the contents of ranitidine HCl as $171{\pm}2.1mg$ ($102{\pm}1.3%$ of the specified contents, RSD of 1.2%) in a tablet of Curan$^{(R)}$. The inter-day precision for 5 days was 1.1% of RSD. For Zantac$^{(R)}$ the within-day precision study (n=4) showed the contents of ranitidine HCl as $167{\pm}0.8mg$ ($99{\pm}0.5%$ of the specified contents, RSD of 0.5%) in a tablet and the inter-day precision for 5 days was 0.3% of RSD.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.