DOI QR코드

DOI QR Code

Descriptive Study for Sonographic Morphology of the 1st Facet of Subscapularis Footprint

견갑하건 부착부의 제1부착면에 대한 초음파 소견의 기술적 연구

  • Sohn, Hoon-Sang (Department of Orthopedic Surgery, Yonsei University Wonju College of Medicine) ;
  • Wi, Chan Kuk (Department of Orthopedic Surgery and Center for Joint Surgery, National Medical Center) ;
  • Shon, Min Soo (Department of Orthopedic Surgery and Center for Joint Surgery, National Medical Center)
  • 손훈상 (연세대학교 원주의과대학 정형외과학교실) ;
  • 위찬국 (국립중앙의료원 관절센터, 정형외과) ;
  • 손민수 (국립중앙의료원 관절센터, 정형외과)
  • Received : 2018.09.25
  • Accepted : 2018.10.26
  • Published : 2019.08.30

Abstract

Purpose: The purpose of this study was to document the sonographic morphology of the subscapularis footprint, particularly the 1st facet, of the non-pathologic subscapularis tendon and footprint, and analyze the correlation between the size of the 1st facet and the demographic variables. Materials and Methods: Between March 2015 and December 2017, retrospectively data analysis was performed for the ultrasound (US) scans of 115 consecutive shoulder (mean age 53.4 years, range 23-74 years) with non-pathologic subscapularis tendon and footprint. The sonographic findings of the 1st facet of the subscapularis footprint was a very unique, flat, broad, and plane angle in the upward direction, which were distinguished from the other facets. On US, the transverse (medio-lateral) and longitudinal (superior-inferior) length of the 1st facet on axis of the humerus shaft were recorded. The demographic variables, including age, site, body height, weight, body mass index (BMI), and arm length, were reviewed. Results: On US, the mean transverse length of the 1st facet was 12.75 mm (range 10.54-14.50 mm, standard deviation [SD] 0.712) and the mean longitudinal length was 12.22 mm (range 9.20-13.30 mm, SD 0.888). The transverse and longitudinal length of the size of the 1st facet were significantly greater in males than in females (p<0.001, p=0.001). Of the demographic data (body height, weight, BMI, arm length) that showed a significant positive linear correlation, the correlation with body height (transverse r=0.749, p<0.001; longitudinal r=0.642, p<0.001) showed the strongest relationship, and the correlation with the BMI was weakly related. The relationships between the size of the 1st facet to site/age were not statistically significant or appeared to have no linear correlation. Conclusion: The structural and morphologic features of the 1st facet of the subscapularis footprint on the US were identified. This will provide anatomic knowledge of an US examination for subscapularis tendon pathology.

목적: 병변이 없는 견갑하건 부착부를 가진 환자를 대상으로 초음파를 통한 견갑하건의 부착부, 특히 제1부착면에 대한 초음파적 영상 소견 및 그 크기를 기술하고 인구통계적 특성과의 상관관계를 분석하고자 하였다. 대상 및 방법: 2015년 3월부터 2017년 12월까지 견갑하건 부착부에서 병변이 없는 것으로 확인된 시행된 115예(평균 연령 53.4세, 범위 23-74세)를 최종 평가대상으로 하여 후향적 분석을 시행하였다. 초음파를 통한 견갑하건의 부착부에 대한 검사상 가장 상부에 위치하면서 제2부착면 이하 부착면들과 뚜렷하게 구별되는 넓고 평편한 형태와 상방으로 향하고 있는 제1부착면을 확인하였으며 제1부착면의 상완골 간부의 축에 대한 횡축과 종축상의 길이를 측정하였다. 또한 각 예의 나이, 성별, 키, 체중, 체질량지수 및 팔 길이를 측정하였다. 결과: 초음파 검사를 통하여 측정된 견갑하건의 제1부착면의 평균 횡적 길이는 12.75 mm (범위 10.54-14.50 mm, 표준편차 0.712), 평균 종적 길이는 12.22 mm (범위 9.20-13.30 mm, 표준편차 0.888)였다. 성별간 견갑하건의 제1부착면의 크기는 횡적 길이와 종적 길이 모두에서 남성에서 유의하게 큰 것으로 확인되었다(p<0.001, p=0.001). 양성의 선형 상관관계를 보이는 키, 체중, 체질량지수, 팔 길이 요소들 중 견갑하건의 제1부착면의 종적 및 횡적 크기 모두에서 키와 가장 강한 양성 선형관계를 보였고(횡적 길이 r=0.749, p<0.001; 종적 길이 r=0.642, p<0.001), 체질량지수와는 약한 양성 선형관계를 보이는 것으로 분석되었다. 그 외 좌우 부위 및 나이는 제1부착면의 크기와의 통계적 유의성이나 선형 상관관계를 보이지는 않았다. 결론: 병변이 없는 견갑하건 부착부의 초음파적 영상 평가를 시행하여 그 부착부, 특히 가장 상부의 제1부착면의 구조적 및 형태적 특성을 확인할 수 있었다. 이는 견갑하건 파열에 대한 초음파 진단적 검사에 대한 해부학적 기초를 제공하게 될 것이다.

Keywords