전자기펄스용접에서 용접강도에 미치는 접합간격의 영향 (Effects of the Stand-off Distance on the Weld Strength in Magnetic Pulse Welding)

  • 김성욱;천창근;김숙환
    • Journal of Welding and Joining
    • /
    • 제26권6호
    • /
    • pp.48-53
    • /
    • 2008
  • Although Magnetic Pulse Welding(MPW) is not a recently developed technique, it has gained the attention of the automotive industry. MPW has become an accepted welding process because it enables the joining of similar, and dissimilar materials, with a very short cycle time, without the need for filler metal and gases. In this study, the effect of the stand-off distance on the weld strength has been investigated. The compressive strength of the MPW joints was evaluated using UTM. The interface of weld, IMC composition and morpology were studied by SEM and EDS. It was concluded that the stand-off distance and the voltage are the main parameters influencing the strength of weld. In case of too high stand-off distance, it influenced harmful effect because of the resistance of deformation.

Comparison between observation and theory for the stand-off distance ratios of CMEs and their associated ICMEs

  • Lee, Jae-Ok;Moon, Yong-Jae;Lee, Jin-Yi;Jang, Soojeong;Lee, Harim
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.81.3-81.3
    • /
    • 2016
  • We examine whether the observational stand-off distance ratios of CMEs and their associated ICMEs could be explained by theoretical model or not. For this, we select 16 CME-ICME pairs from September 2009 to October 2012 with the following conditions: (1) limb CMEs by SOHO and their associated ICMEs by twin STEREO spacecraft and vice versa when both spacecraft were roughly in quadrature; (2) the faint structure ahead of a limb CME is well identified; and (3) its associated ICME clearly has a sheath structure. We determine the observational stand-off distance ratios of the CMEs by using brightness profiles from LASCO-C2 (or SECCHI-COR2) observations and those of the ICMEs by solar wind data from STEREO-IMPACT/PLASTIC (or OMNI database) observations. We also determine the theoretical stand-off distance ratios of the CME-ICME pairs using semi-empirical relationship based on the bow shock theory. We find the following results. (1) Observational CME stand-off distance ratio decreases with increasing Mach number at the Mach numbers between 2 and 6. This tendency is consistent with the results from the semi-empirical relationship. (2) The observational stand-off distance ratios of several ICMEs can be explained by the relationship.

  • PDF

비평형 극음속 유동에서 구에 대한 충격파 이탈거리 계산 (CALCULATION OF SHOCK STAND-OFF DISTANCE FOR A SPHERE IN NONEQUILIBRIUM HYPERSONIC FLOW)

  • Furudate, M. Ahn
    • 한국전산유체공학회지
    • /
    • 제17권4호
    • /
    • pp.69-74
    • /
    • 2012
  • Hypersonic flowfields over a sphere is calculated by using a nonequilibrium flow solver. The flow solver features a two-temperature model and finite rate chemical reaction models to describe nonequilibrium thermochemical processes. For the purpose of validation, the calculated shock stand-off distance is compared with the experimental data which is measured in a ballistic range facility. The present nonequilibrium calculation well reproduced the experimental shock stand-off distance in the cases where the experimental flowfields are expected to be nearly equilibrium, as well as in the cases to be nonequilibrium flowfields in the velocity range 4000 to 5500 m/s.

자동전원 계폐장치에 관한 연구 (Study on Divice for the Automatic Shut Off of Equipment Stand-by Power)

  • 김형광;현기웅;배종일;양순용;박성태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2626-2627
    • /
    • 1999
  • The device we have developed is the automatic shut off equipment which will reduce energy consumption when an equipment is in stand by power state. The principle for this system is when a man is moving, electricity will flow by setting a on-off light system. At night, in the stand-by power state the electric supply will be shut off immediately which will reduce energy consumption. Energy consumed by 24hour operating machines and stand-by electronic devices will be reduced by pulse signals which will give power supply when needed.

  • PDF

비접촉식 지표면 화학 오염 탐지용 라만 분광시스템 설계 및 성능확인 (The Design and Test of the Stand-off Surface Chemical Contaminant Detection System based on Raman Spectroscopy)

  • 고영진
    • 한국군사과학기술학회지
    • /
    • 제22권3호
    • /
    • pp.433-440
    • /
    • 2019
  • In order to detect toxic chemical spread on field ground, we developed stand-off Raman spectrometer system which employed a deep UV laser. In this paper, the design and specification of various components in the spectrometer system are described. Some results when the detection system was tested on the outdoor roads are shown, which may help researching stand-off chemical detectors based on Raman spectroscopy.

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.

Effects of Sit-to-stand Training with Various Foot Positions Combined with Visual Feedback on Postural Alignment and Balance in Stroke Patients

  • Kim, Su-Jin;Son, Ho-Hee
    • 대한물리의학회지
    • /
    • 제16권4호
    • /
    • pp.55-65
    • /
    • 2021
  • PURPOSE: This study compared the effects of sit-to-stand training with various foot positions combined with visual feedback on the postural alignment and balance. METHODS: Thirty stroke patients were assigned randomly into three groups of standing with a symmetrical foot position (SSF) (n = 10), asymmetrical foot position with the affected foot at the rear (SAF) (n = 10), and visual feedback and asymmetrical foot position (SVAF) (n = 10). Sit-to-stand training with different foot positions was performed for 30 minutes a day, five times a week, for a total of four weeks, and the effects on postural alignment and balance were assessed. RESULTS: The angle between the midline and scapula peak of the affected side was decreased significantly at sitting and thigh-off in the SAF group and at sitting, thigh-off, and standing in the SVAF group (p < .05). The angle between the midline and scapula peak of the non-affected side was increased significantly at sitting and thigh-off in the SAF group and at sitting, thigh-off, and standing in the SVAF group, the difference in the angle between the scapular peaks of the left and right sides was decreased significantly at sitting and thigh-off in SSF group, and at sitting in SAF group (p < .05). In the SVAF group, the angle at sitting, thigh-off, and standing was decreased significantly (p < .05). A comparison of the balance ability showed that BSS in the SVAF group was improved significantly (p < .05). CONCLUSION: Based on these results, the postural alignment and balance ability were improved in stroke patients who participated in sit-to-stand with visual feedback and asymmetrical foot position training.

ALBC3 합금의 쇼트피닝 분사거리에 따른 해수 내 캐비테이션 손상 평가 (Evaluation on cavitation damage in sea water with shot peening stand-off distance for ALBC3 alloy)

  • 한민수;장석기;김종신;김성종
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.239-244
    • /
    • 2013
  • Marine equipment exposed to harsh environments requires not only excellent corrosion resistance but also improvement of physical characteristics against natural material degradation. With growing interests in ocean energy resources, the higher reliability for marine equipment has become more important in terms of material characteristics. ALBC3 alloy represents excellent corrosion resistance and is widely used in corrosive environments. However, cavitation damage occurs frequently due to its poor durability in high flow rate of marine environment. In this research, shot peening technology was employed as a surface modification with shot peening stand-off distance to mitigate cavitation damage. The effects of shot peening on extent of cavitation damage and weight loss were evaluated for both shot peened and non-peened specimens. The results revealed that the application of shot peeing decreased cavitation damage for all experimental conditions in comparison with the non-peened specimens. The optimum stand-off distance was determined to be 10 cm, since more than 35 % of cavitation damage reduction was observed.

ALBC3 합금의 표면 개질을 위한 쇼트피닝 분사거리가 전기화학적 특성에 미치는 영향 (Effects of shot peening stand-off distance on electrochemical properties for surface modification of ALBC3 alloy)

  • 한민수;현광용;김성종
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.233-238
    • /
    • 2013
  • In the case of casting materials or ductile materials for marine equipment, it is common to employ a surface modification for achieving cost reduction and improvement in strength. In particular, aluminium bronze ALBC3 exhibits excellent corrosion resistance, and thus widely used for marine application. However, application of the material under high-velocity seawater flow may induce electrochemical corrosion damage and physical damage such as cavitation erosion, leading to shorter service life of equipment. In this study, surface modification was carried out on ALBC3 alloy for different shot peening stand-off distances, and the physical hardness and electrochemical characteristics before and after modification were investigated. The results in each case showed the hardness increase in comparison with non-peened specimen, and the maximum hardness improvement(50 %) was found in 10 cm of shot-peening stand-off distance. It is observed that the electrochemical characteristics were irrelevant to application of shot peening.