• Title/Summary/Keyword: stand-by mode

Search Result 101, Processing Time 0.024 seconds

A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators

  • Kesler, Selami;Doser, Tayyip L.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1869-1883
    • /
    • 2016
  • In recent years, some converter structures and analyzing methods for the voltage regulation of stand-alone self-excited induction generators (SEIGs) have been introduced. However, all of them are concerned with the three-phase voltage control of three-phase SEIGs or the single-phase voltage control of single-phase SEIGs for the operation of these machines under balanced load conditions. In this paper, each phase voltage is controlled separately through separated converters, which consist of a full-bridge diode rectifier and one-IGBT. For this purpose, the principle of the electronic load controllers supported by fuzzy logic is employed in the two-different proposed converter structures. While changing single phase consumer loads that are independent from each other, the output voltages of the generator are controlled independently by three-number of separated electronic load controllers (SELCs) in two different mode operations. The aim is to obtain a rated power from the SEIG via the switching of the dump loads to be the complement of consumer load variations. The transient and steady state behaviors of the whole system are investigated by simulation studies from the point of getting the design parameters, and experiments are carried out for validation of the results. The results illustrate that the proposed SELC system is capable of coping with independent consumer load variations to keep output voltage at a desired value for each phase. It is also available for unbalanced consumer load conditions. In addition, it is concluded that the proposed converter without a filter capacitor has less harmonics on the currents.

The Study On Developing Low Power PLC Modem based on Stand-by Mode Function (저전력 대기모드를 지원하는 전력선통신 모뎀 개발에 관한 연구)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Won, Dong-Sun;Park, Chung-Ha;Song, Yong-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.536-537
    • /
    • 2008
  • 최근 홈 네트워킹 기술과 연동된 가전제어 및 서비스에 대한니즈가 증대�� 있어 다양한 디지털 가전기기가 개발되고 있다. 특히 국내외적으로 많은 홈 네트워크 관련 제품들이 생산되고 있으며 이는 궁극적으로 이기종 네트워크 환경에서 유무선 통신의 구된 없이 다양한 기기를 네트워크에 접속할 수 있는 서비스를 제공한다. 기존 중 저속 전력선 모뎀의 경우 홈 네트워크에서 전력선으로 들어오는 신호를 수신하기 위해 전력소모가 가장 많은 Main Processor에서는 항상 Wake-On 상태를 유지하고 있다. 하지만 중 저속 전력선 모뎀의 송수신을 관장하는 Main Processor를 보게 되면 크게 통신 프로토콜을 관장하는 Main CPU와 실제 전력선 신호 송수신을 관장하는 PLC Core로 나뉠 수 있다. 홈네트워크상에 전력선으로 들어오는 신호를 수신하기 위해서는 PLC Core는 항상 Wake-On 상태를 유지해야 하지만 Main CPU의 경우는 전력소모를 최소화하기 위해 Idle 상태를 유지하더라도 Host Controller와의 Stand-by & Wake On 신호와 인터럽트 발생기능을 이용하게 되면 전력선 통신에 문제가 없이 대기모드를 지원하는 저전력 전력선 통신 모뎀 개발이 가능하다. 이에 본 연구에서는 저전력 대기모드를 지원하는 전력선 통신 모뎀 개발에 관한 연구를 하고자 한다.

  • PDF

Design of Low-Area DC-DC Converter for 1.5V 256kb eFlash Memory IPs (1.5V 256kb eFlash 메모리 IP용 저면적 DC-DC Converter 설계)

  • Kim, YoungHee;Jin, HongZhou;Ha, PanBong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.144-151
    • /
    • 2022
  • In this paper, a 1.5V 256kb eFlash memory IP with low area DC-DC converter is designed for battery application. Therefore, in this paper, 5V NMOS precharging transistor is used instead of cross-coupled 5V NMOS transistor, which is a circuit that precharges the voltage of the pumping node to VIN voltage in the unit charge pump circuit for the design of a low-area DC-DC converter. A 5V cross-coupled PMOS transistor is used as a transistor that transfers the boosted voltage to the VOUT node. In addition, the gate node of the 5V NMOS precharging transistor is made to swing between VIN voltage and VIN+VDD voltage using a boost-clock generator. Furthermore, to swing the clock signal, which is one node of the pumping capacitor, to full VDD during a small ring oscillation period in the multi-stage charge pump circuit, a local inverter is added to each unit charge pump circuit. And when exiting from erase mode and program mode and staying at stand-by state, HV NMOS transistor is used to precharge to VDD voltage instead of using a circuit that precharges the boosted voltage to VDD voltage. Since the proposed circuit is applied to the DC-DC converter circuit, the layout area of the 256kb eFLASH memory IP is reduced by about 6.5% compared to the case of using the conventional DC-DC converter circuit.

Integrated Simulation Model for Designing Distributed Energy Management System in Microgrid System (마이크로그리드시스템의 분산 에너지관리시스템 설계를 위한 통합시뮬레이션 모델 개발)

  • Cho, Jae-Hoon;Park, Sun-Hong;Lee, Dae-Jong;Cho, Young-Im;Chun, Myung-Geun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.1
    • /
    • pp.29-35
    • /
    • 2011
  • In this paper, an integrated simulation model for designing multi-agent system based DEMS (distributed energy management system) in stand-alone micro-grid system is proposed. In the design of the EMS(energy management system), the multi-agent based DEMS are more effective than conventional centralized EMS, but it is difficult to design the DEMS by general design tools for power system because of various states of a microgrid system during operation of stand-alone mode. Also, since performance test of the DEMS using a real system is inefficient, an integrated simulation model is required for designing an effective multi-agent system based DEMS. The proposed model consists of Matlab/SimPowerSystems based simulation model of the microgrid system and the Multi-agnet based DEMS designed by Matlab/StateFlow tool. In order to show the effect of the proposed model, the model outputs are analyzed for specified operation conditions.

Frequency Control of Battery Energy Storage System with a Deadband and Restoration Control in Microgrid (마이크로그리드에서의 데드 밴드와 회복 제어를 적용한 배터리 에너지저장시스템 주파수 제어)

  • Lee, Hak-Ju;Choi, Jin-Young;Choi, Jong-Chan;Won, Dong-Jun;Chae, Woo-Kyu;Park, Jung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1584-1589
    • /
    • 2012
  • The grid-interconnected microgrid can be able to operate with and without the utility microgrid to supply electricity. when the microgrid operates in grid-connected mode, the frequency of the microgrid synchronizes with the system frequency. In this case, the frequency of the microgrid has small variation which is able to change the output of distributed generation with a droop controller. Thus, the small variation of frequency can make the distributed generation generate unnecessary electricity consistently. In this paper, we propose a frequency droop control with a dead band so as to prevent the distributed generations from generating unnecessary output while in grid-interconnected mode. In addition, a distributed generation can have a restoration control to restore the frequency changed by a droop control as a rated frequency. Also, we state the problem of restoration control with a dead band, and propose its solution when the microgrid operates in stand alone mode. We simulate the proposed droop control using PSCAD/EMTDC to verify the validity of the control.

Sliding Mode Control of a New Wind-Based Isolated Three-Phase Induction Generator System with Constant Frequency and Adjustable Output Voltage

  • Moradian, Mohammadreza;Soltani, Jafar
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.675-684
    • /
    • 2016
  • This paper presents a new stand-alone wind-based induction generator system with constant frequency and adjustable output voltage. The proposed generator consists of a six-phase cage-rotor induction machine with two separate three-phase balanced stator windings and a three-phase space vector pulse width modulation inverter that operates as a static synchronous compensator (STATCOM). The first stator winding is fed by the STATCOM and used to excite the machine while the second stator winding is connected to the generator external load. The main frequency of the STATCOM is determined to be constant and equal to the load-requested frequency. The generator output frequency is independent of the load power demand and its prime mover speed because the frequency of the induced emf in the second stator winding is the same as this constant frequency. A sliding mode control (SMC) is developed to regulate the generator output voltage. A second SMC is used to force the zero active power exchanged between the machine and the STATCOM. Some simulation and experimental results are presented to prove the validity and effectiveness of the proposed generator system.

Optimized LCL filter Design Method of Utility Interactive Inverter (계통연계형 인버터의 LCL필터 최적 설계기법)

  • Jung, Sang-Hyuk;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.

Smart Power Management System for Leisure-ship

  • Park, Do-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.749-753
    • /
    • 2011
  • A leisure ship has a stand-alone type power system, and a generator is in use on this condition. But the generator cannot be operated in condition of leisure activity, ocean measurement and etc, because of environment and noise. Recently, renewable energy system is connected with power system of the leisure-ship for saving energy. The renewable energy system can not supply the stable power to leisure-ship because power generation changes according to weather condition. And most of the leisure ship is operated without methodical power management system. This study's purpose is to develop SPMS(Smart Power Management System) algorithm using the renewable energy (photovoltaic, wind power and etc.). The proposed algorithm is able to supply stable the power according to operation mode. Furthermore, the SPMS manages electric load (sailing and communication equipment, TV, fan, etc.) and reduces operating times of the generator. In this paper, the proposed algorithm is realized and executed by using LabVIEW. As a result, the hour for operating the generator is minimized.

Maximum Output Power Control for Stand-Alone Wind Power Generation System Using Cage-Type Induction Generators (농형 유도발전기를 이용한 독립형 풍력발전시스템의 최대출력제어)

  • 김형균;이동춘;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.73-80
    • /
    • 2004
  • In this paper, a maximum output power control of stand-alone cage-type induction generator systems for wind power generation is proposed. The induction generator is operated in a vector-controlled mode, which is excited with d-axis current and of which torque is controlled with q-axis current. The generator speed is controlled by this torque, along which speed the generator produces the maximum output power. The generated power charges the battery bank for energy storage through an ac/dc PWM converter. The proposed scheme has been verified for the wind turbine simulator system which consists of M-G set.

Studies on microbial population affecting the decomposition of fir litter. (전나무낙엽의 분해에 따른 Microbial population의 변화에 관한 연구)

  • Jang, Nam Gi;Im, Yeong Deuk
    • Korean Journal of Microbiology
    • /
    • v.6 no.3
    • /
    • pp.92-92
    • /
    • 1968
  • 1) The aim of present investigation is to elucidate the relation of the balance of the production and decomposition of the fir litter. in Kwangnung plantation stands. 2) The decay constant, K, of litters was 0. 185 for the fir stand at Kwangnung. 3) The mode for the accumulation of organic carbon ($C_a$) is $c_a$= $610(1-e^{-0.185t})$), and for the decay of organic carbon (C) C = $610(1-e^{-0.185t})$. 4) The time required for the decay of half of the accumulated organic carbon in the fir stand is 3. 74 years and for 99% of elimination 27.02 years. 5) The litters of Abies holophylla killed by heat and washed with alcohol-benzol, with hot water, or with both alcohol-benzol and hot water were incubated after inoculated with suspension of firwood soil. Plate counts were made of fungi and bacteria from time to time. 6) Removal of the alcohol-benzol soluble substance stimulates at the beginning of the decay the growth of fungi and also of bacteria. 7) Removal of the water soluble fraction is detrimental to the growth of fungi in particular. 8) The distribution of soil microbial population is higher in both F and H horizon of the fir plantation soil in Kwangnung. However, the number of soil microorganisms decreases with the depth in forest soil.