DOI QR코드

DOI QR Code

Smart Power Management System for Leisure-ship

  • Park, Do-Young (Division of Mechatronics Engineering, Korea Maritime University) ;
  • Oh, Jin-Seok (Division of Mechatronics Engineering, Korea Maritime University)
  • Received : 2011.10.31
  • Accepted : 2011.12.21
  • Published : 2011.12.31

Abstract

A leisure ship has a stand-alone type power system, and a generator is in use on this condition. But the generator cannot be operated in condition of leisure activity, ocean measurement and etc, because of environment and noise. Recently, renewable energy system is connected with power system of the leisure-ship for saving energy. The renewable energy system can not supply the stable power to leisure-ship because power generation changes according to weather condition. And most of the leisure ship is operated without methodical power management system. This study's purpose is to develop SPMS(Smart Power Management System) algorithm using the renewable energy (photovoltaic, wind power and etc.). The proposed algorithm is able to supply stable the power according to operation mode. Furthermore, the SPMS manages electric load (sailing and communication equipment, TV, fan, etc.) and reduces operating times of the generator. In this paper, the proposed algorithm is realized and executed by using LabVIEW. As a result, the hour for operating the generator is minimized.

Keywords

References

  1. Choe, G.Y, Kim, J.S, Lee, B.K, Won, C.Y, Lee, T.W (2010), "A Bi-directional Battery Charger System Integrated Photovoltaic PCS", Journal of the Korean Institute of Power Electronics, pp 192-193.
  2. Jung, Y.S, Yu, G.J, Kang, G.H, Song, J.S, Kim, H.S(2000), "Analysis on the Characteristics of Photovoltaic / Wind Hybrid PCS System", Journal of the Korean Institute of Power Electronics, Vol. 5, No. 1, pp 19-25.
  3. Jo, K.J, Jung, S.Y, Bae, S.Y, Lee, J.Y, Oh, J.S(2009), "A Study on the MPPT Algorithm For Buoy", Journal of the Korean Society of Marine Engineering, Vol.33, NO.4, pp. 588-594. https://doi.org/10.5916/jkosme.2009.33.4.588
  4. Kim, T.H, Lee, S.Y, Shin, M.C, Cha, J.S, Suh, H.S, Kim, J.B, Choi, S.Y(2004), "Direct Load Control Using Priority Based Dynamic Programming" Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol. 18, No.6, pp. 78-83. https://doi.org/10.5207/JIEIE.2004.18.6.078
  5. Lee, J.H, Hong, S.H(2010), "Implementat -ion of Smart Controller Using IEEE451 for Smart shore" The Institute of Electronics Engineers of Korea, Vol. 33, No. 1, pp. 1721-1724.
  6. Seo, C.S, Moon, J.H, Park, J.W, Kim, G.S, Kim, D.H (2008), "The Battery Management System for UPS Lead-Acid Battery" Journal of the Korean Institute of Illuminating and Electrical Installation Engineers Vol. 22, No.6, pp. 127-133. https://doi.org/10.5207/JIEIE.2008.22.6.127