• Title/Summary/Keyword: stand-alone operation

Search Result 115, Processing Time 0.027 seconds

Supply Chain Management and Simulation (공급사슬경영과 시뮬레이션)

  • Seo, Seok-Joo;Kim, Kyung-Sup
    • IE interfaces
    • /
    • v.13 no.3
    • /
    • pp.328-338
    • /
    • 2000
  • This paper reviews the general concept and application area of Supply Chain Management (SCM). Then, the general concept, function, modeling methodology, and operation methodology of Supply Chain Simulation are also reviewed. SCM software solutions and their modules developed by popular IT companies are introduced and compared. The role of simulation in SCM is emphasized as a strategic decision making solution for modeling and analyzing dynamics of a supply chain. Several stand-alone supply chain simulators are introduced and compared.

  • PDF

Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator (디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구)

  • Jo, Jongmin;An, Hyunsung;Kim, Jichan;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.

Design Method and Development Status of Photovoltaic System (태양광발전시스템의 설계법과 개발동향)

  • Yu, Kwon-Jong;Song, Jin-Soo;Jung, Myong-Woong;Kang, Kee-Whan
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1048-1051
    • /
    • 1992
  • The design method is a crucial factor for the successful operation of photovoltaic system. A design method is proposed and applied practically to a stand-alone system of 25KWp aimed at the power supply for a remote-island. In this paper the operation results of this system are discussed. In addition, the current status and future prospects at home and abroad on the development of photovoltaic systems are also described.

  • PDF

A Study on the Torque Optimization of Parking Sign system (주차판 표시장치의 토크 최적화에 대한 연구)

  • 정양희;이보희;유일현;최상호;김종태
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.3
    • /
    • pp.543-551
    • /
    • 2001
  • This paper is concerned with optimization of a motor torque to drive Parking Sign system. It needs to minimize powers for stand alone operation and requires the optimized parameters in order to move the plates in the minimum torque. The operation can be represented as a complicated non-linear equation which is difficult to solve by general optimization techniques. In this paper, the dynamic equations of the system are derived, also the suitable Genetic Algorithm is designed to solve the equations. Computer simulation shows the availability of this method.

  • PDF

Variable Priority Number Control of SPMS for Leisure Ship

  • Oh, Jin-Seok;Park, Do-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.141-148
    • /
    • 2012
  • The power system of leisure ship has a character of stand-alone type, so it continuously checks the usable power. Especially, the leisure ship using renewable energy needs to adjust the power consumption of loads according to the usable power. Also, the important loads of leisure ship are different by operation mode. However, current power management system doesnot consider such character. This paper studied load management system of the SPMS(Smart Power Management System) and composed using the smart plug. The SPMS controls the loads depending on a user's pattern and character through variable priority number control. This control algorithm was verified through simulation of assumed user and situation using LabVIEW.

Operation Algorithm of Hybrid Power System for Power Supply in a Remote Island (낙도 전력공급을 위한 복합발전시스템의 운전제어 알고리즘)

  • Kim, E.S.;Kim, S.K.;Lee, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.293-295
    • /
    • 2001
  • In this paper, a control algorithm of a stand-alone type photovoltaic/wind/diesel hybrid power system for operation in a remote island, is proposed in detail. Power controllers are used to combine two different power outputs of photovoltaic and wind-power generations into DC output, which is converted into AC power to meet load while charging the storage battery for later use. In the event that the whole power load cannot be met by photovoltaic and wind power only, power stored in the battery cell is supplied and if even this power run out, diesel generator will be applied. Certain portion of diesel power is used to cover the load and the other to charge the battery.

  • PDF

Calculation of capacity of solar cell and battery for stable solar system design (안정적인 태양광발전시스템의 설계를 위한 태양전지와 배터리 용량산정 방안)

  • Lee Mi-Young;Lee Jun-Ha;Lee Hoong-Joo;Lee Woo-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.5
    • /
    • pp.396-400
    • /
    • 2005
  • Solar cell and battery capacity are very important for stable design of stand-alone solar photovoltaic power generation system. If capacity computation of solar cell and battery is a wrong, operation of the solar system becomes unstable and results in breakdown. Therefore, in this paper, a solar cell and battery capacity calculation method considering the load characteristics has been proposed for the stable operation of the solar photovoltaic power generation system.

  • PDF

Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters (간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환)

  • Song, Injong;Choi, Junsoo;Lim, Kyungbae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

Power Control and Dynamic Performance Analysis of a Grid-Interactive Wind/PV/BESS Hybrid System (계통연계형 풍력, 태양광 및 축전지 하이브리드 시스템의 출력제어 및 동특성 해석)

  • Kim, Seul-Ki;Jeon, Jin-Hong;Cho, Chang-Hee;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.317-324
    • /
    • 2007
  • Most conventional hybrid systems using renewable energy sources have been applied for stand-alone operation, but Utility-interface may be an useful and viable option for hybrid systems. Grid-connected operation may have benefits such as reduced losses in power system distribution, utility support in demand side management, and peak load shaving. This paper addresses power control and dynamic performance of a grid-connected PV/wind/BESS hybrid system. At all times the PV way and the wind turbine are individually controlled to generate the maximum energy from given weather conditions. The battery energy storage system (BESS) charges or discharges the battery depending on energy gap between grid invertger generation and production from the PV and wind system. The BESS should be also controlled without too frequently repeated shifts in operation mode, charging or discharging. The grid inverter regulates the generated power injection into the grid. Different control schemes of the grid inverter are presented for different operation modes, which include normal operation, power dispatching, and power smoothing. Simulation results demonstrate that the effectiveness of the proposed power control schemes for the grid-interactive hybrid system.

A Study on the Fault Tolerance and High Efficiency Control of 4 Leg DC/DC Converter for Battery Energy Storage System in Standalone DC Micro-grid (독립형 DC마이크로그리드 내 BESS용 4 LEG DC/DC 컨버터의 고장허용 및 고효율 제어에 관한 연구)

  • Choi, Jung-Sik;Oh, Seung-Yeol;Cha, Dae-Seak;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1239-1248
    • /
    • 2018
  • This paper proposes a fault tolerant and high efficiency operation algorithm for a 4 LEG DC/DC converter for a battery energy storage system(BESS) forming a main power source in a standalone DC micro grid. The BESS for the main power supply in the stand-alone DC micro-grid is required to operate at high speed according to fault tolerant control and load by operating at all times. Fault-tolerance control changes the short-circuit fault to an open-circuit fault by using a fuse in case of leg fault in 4 legs, and operates stably through phase shift control. In addition, considering the loss of the power semiconductor, the number of LEG operation is adjusted to operate at high efficiency in the full load region. In this paper, fault tolerant control and high efficiency operation algorithm of DC/DC converter for BESS in standalone DC micro grid is presented and it is proved through simulation and experiment.