• Title/Summary/Keyword: stainless steel crown

Search Result 90, Processing Time 0.021 seconds

A Fuzzy Shape Control Method for the Stainless Steel at the Cold Rolling Process (스테인리스 냉연공정에서 퍼지 형상제어)

  • Hur, Yone-Gi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.10
    • /
    • pp.1062-1070
    • /
    • 2009
  • The strip shape for the stainless steel process has made an issue of the strip quality, and hence the shape control method is developed at the Sendzimir rolling mill (ZRM). ZRM is a stainless cold rolling mill and has actuators for the shape control. They are first intermediate rolls and top crown rolls, which are controlled horizontally and vertically, respectively. The shape control of the stainless steel rolling process has difficulty in obtaining the symmetrical shape. The objective of the shape control is to minimize the shape deviation and to maintain stable state, which keeps symmetrical shape pattern in the lateral direction. The method of the shape recognition employs a least squares method and neural network. The shape deviation is the difference between the target shape and actual shape and is controlled by the fuzzy shape control. The fuzzy shape control using operator's informative knowledge is proposed in this paper. The experiments are carried out online for various stainless materials and sizes. The productivity of the rolling process has increased from 9.0 to 9.4 tons per hour.

Micro-CT Evaluation of Stainless Steel Crowns on Extracted Primary Molars (Micro-CT를 이용한 발거된 유구치의 기성금속관 평가)

  • Jung, Boram;Shin, Jonghyun;Jeong, Taesung;Kim, Jiyeon;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.1
    • /
    • pp.53-61
    • /
    • 2015
  • This study was conducted for the purpose of evaluating the stainless steel crowns on extracted primary molars and thus identifying frequent errors and defects. Visual assessment and micro-computed tomography (micro-CT) image analysis were performed on 97 primary molars for evaluation of the state of marginal adaptation, cement loss, secondary caries, ledge formation, attritive perforation and marginal polishing defect. The results were as follows: In the examination of object teeth by evaluation criteria, cement loss was found most frequently (98%), followed by secondary caries (42.3%), marginal polishing defect (41.2%), ledge formation (29.9%) and attritive perforation (17.5%), in this order. The cement loss at the margins showed a significant relationship with marginal gap and secondary caries: the larger the marginal gap is, the more frequent is the cement loss (p < 0.05). The average marginal gap was $0.31{\pm}0.26mm$ and showed the highest value in the maxillary 2nd primary molars. The location of the crown margin above the cementoenamel junction was found most frequently and it was found that the higher the crown margin is located, the less the marginal gap becomes (p < 0.05). In conclusion, it is thought very desirable to pay closer attention to crown margins and shapes for stainless steel crown restoration in order to minimize the marginal gaps and consequent cement loss.

THE STAINLESS STEEL CROWN RESTORATION OF CARIOUS PRIMARY MOLARS WITH HALL TECHNIQUE : A CASE REPORT (Hall technique을 이용한 우식 유구치의 기성 금속관 수복 : 증례보고)

  • Yu, Seong-Goo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.199-205
    • /
    • 2012
  • Although the stainless steel crowns have been recognized as the most effective and durable form of restoration for primary molars, they have been regarded by many dentists as having definite demerits such as invasive nature of procedural complexity and behavioral aspects of children. As an alternative to conventional technique of stainless steel crown restoration, the Hall technique was first introduced in 1988, which is characterized by just pushing the pre-contoured, cement filled crown form onto the abutment molar with no local anesthesia, no caries removal, no tooth preparation. According to several reports, this can slow, arrest, or even reverse the progress of caries. In addition, its atraumatic feature gives less discomfort and stress to children than conventional one, which is thought excellent especially in younger children. Also, It has been reported to be effective and acceptable to dentist, child patients and their parents. In this case study, three children with age of 4 years 5 months, 4 years 10 months, 6 years 4 months were treated with stainless steel crowns using Hall technique on first primary molar respectively. The teeth were free from pulpal, periapical pathology. After follow up of about 3 to 6 months period, the results showed clinically successful outcomes without any marked complication in pulp, tooth or soft tissue till now. But, it should be kept in mind that this technique is not proper to every child, every carious molar, or every dentist. Thorough distinction of indicated cases and continuous follow-up check is highly required. Conclusively, Hall technique might be an effective and realistic minimally invasive alternative for the carious primary molars especially in younger or disabled children, despite potential doubts on its efficacy and some definite limitations.

Comparison of Partial Pulpotomy in Permanent Molars Using Different Pulp Capping Agents and Restoration Materials (치수복조재와 최종수복재에 따른 대구치 부분치수절단술의 비교)

  • Lee, Jimi;Lee, Nanyoung;Lee, Sangho;Jih, Myeongkwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.2
    • /
    • pp.148-156
    • /
    • 2020
  • The purpose of this study was to compare the success rates of two pulp capping materials, Biodentine™ and RetroMTA®, used for partial pulpotomy in permanent molars after carious exposures and to compare the final restorative outcome of using composite resin to that of using a stainless steel crown. We studied children who were diagnosed with dental caries of permanent molars and underwent partial pulpotomy. The patients were followed up for more than 1 year. Clinical and radiographic evaluation were used to evaluate the success of each treatment. Fisher's exact test was used to compare the outcomes of two groups. For pulp capping agents, the success rate of using RetroMTA® was lower than that of using Biodentine™(p < 0.05). Final restoration with composite resin was less successful than restoration with an stainless steel crown(p < 0.05). In combination of pulp capping agents and final restoration material, RetroMTA®-composite resin shows the lowest success rate(p < 0.05).

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

TYPE II DENTINOGENESIS IMPERFECTA : CASE REPORT (Type II 상아질형성부전증의 임상 증례)

  • Kim, Chi-Hyun;Lee, Jae-Ho;Choi, Byung-Jai;Lee, Chong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.654-660
    • /
    • 2001
  • Dentinogenesis imperfecta is an example of an inheritable dentinal defect originating during the histodifferentiation stage of tooth development, with involvement of the primary and permanent teeth. Shields, Bixler and El-Kafrawy proposed three types of Dentinogenesis imperfecta : Type I, II, III. Witkop reported a prevalence of 1 in 8000 with the trait, and no significant difference between male and female. Affected teeth have red-brown discoloration often with distinctive wearness of occlusal surface of posterior teeth and incisal surface of anterior teeth. Once enamel seperated from underlying defective dentin, the dentin demonstrates significantly acclerated attrision. Radiographically, the teeth have thin roots, bulbous crown, cervical constriction, and obliteration of the root canals and pulp chambers. In primary dentition periapical lesions or multiple root fractures are often observed. In successive generations the phenotypes of discoloration and wearness of teeth occurred, and one of the patient's subships, 10 year-old sister, showed general discoloration of her teeth and mild wearness. In this case, a 4 year-old male reported to the Yonsei University Pedodontics clinic, with a chief complaint of discolored teeth. The teeth showed generally yellowish-brown discoloration and moderate wearness. In radiographic features, obliteration of pulp, bulbous crown, and short roots were observed. It was diagnosed as Dentinogenesis imperfecta. The posterior teeth were restored with Stainless Steel Crown, and defective incisors including left upper primary central incisor which was extracted due to a root fracture with Open-faced Stainless Steel crown.

  • PDF

Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns

  • Choi, Jae-Won;Bae, Ik-Hyun;Noh, Tae-Hwan;Ju, Sung-Won;Lee, Tae-Kyoung;Ahn, Jin-Soo;Jeong, Tae-Sung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2016
  • PURPOSE. This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS. There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey's test (P<.05). RESULTS. The Leucite group ($2.670{\pm}1.471mm^3$) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium ($2.042{\pm}0.696mm^3$), Zirconia ($1.426{\pm}0.477mm^3$), and Steel groups ($0.397{\pm}0.192mm^3$). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05). CONCLUSION. Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia.