• Title/Summary/Keyword: stack effect

Search Result 325, Processing Time 0.025 seconds

A Study on the Characteristics of Voltage Distribution of Stacked YBCO Coated Conductors in Series Connection

  • Chu, Sung-Yul;Hwang, Young-Jin;Kim, Young-Jae;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.4
    • /
    • pp.25-28
    • /
    • 2009
  • In order to apply superconducting electric machineries such as a Superconducting Fault Current Limiter (SFCL) to the power grid, the single module should be connected in series to have reasonable size. Superconducting tapes in the module also should be stacked to satisfy requirements such as large operation current of the power grid. This is because a single superconducting tape has restricted applicable current capacity. Moreover especially in SFCL at the fault, there should be equal voltage distribution in series-connected SFCL modules. In this paper, we investigated the voltage distribution in fault current of series-connected YBCO coated conductors (CC). Depending on characteristics of the CC samples such as critical current, even voltage distribution could be achieved or not. In addition, the effect of stacked CC on the change of voltage distribution comparing to non-stack cases in series connection was confirmed by experiments. As the CC stacked, voltage difference could be reduced.

Effect of Ceramic-Electrode Interface on the Electrical Properties of Multilayer Ceramic Actuators (적층형 세라믹 액츄에이터의 세라믹-전극간 계면이 전기적 특성에 미치는 영향에 대한 연구)

  • 하문수;정순종;송재성;이재신
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.896-901
    • /
    • 2002
  • The polarization and strain behavior of multilayer ceramic actuators fabricated by tape casting using a PNN-PZT ceramics were investigated in association with electrode size and internal layer number. Spontaneous polarization and strain decreased with increasing electrode size. In addition, the increase of internal layer number brought reduced spontaneous polarization and increased the field-induced strain. Because the actuators structure is designed to stack ceramic layer and electrode layer alternatively, the ceramic-electrode interfaces may act as a resistance to motion of domain wall. To analyze the effect of ceramic-electrode interface, the diffraction intensity ratio of (002) to (200) planes was calculated from X-ray diffraction patterns of samples subjected to a voltage of 200 V. The diffraction intensity ratio of (002) to (200) planes was decreased with increasing electrode size and internal layer number. The diffraction intensity ratio and straining behavior analyses indicate that the Polarization and strain were affected by the amount of 90°domain decreasing with increasing electrode size and internal layer number. Consequently, the change of polarization and displacement with respect to electrode size and layer number is likely to be caused by readiness of the domain wall movement around the interface.

Study on Application of Shaft Box type Balcony for Improvement of Ventilation Performance in Apartment (공동주택의 환기성능 개선을 위한 Shaft Box형 발코니의 적용성 검토)

  • Roh, Ji-Woong;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, because of the continuous rise of international oil price, energy saving is strongly demanding. So, Ecological technics of architecture such as use of natural energy have been actively explored in the field of building. In the method of utilizing natural energy, the key point is to saving energy effectively as not lowering the comfort of indoor environment, various systems investigated. Many papers about double skin facade system have been reported, it is announced broadly that the system is very effective in improvement of natural ventilation and indoor thermal environment, and also protecting outdoor sound. The shaft box facade is a special form of box window construction. It consists of a system of box windows with continuous vertical shafts that extend over a number of stories to create a stack effect. The facade layout consists of an alternation of box windows and vertical shaft segments. This research investigated the natural ventilation performance of shaft box type balcony which conform the shaft box type double skin to the exiting balcony construction. First, analyzed various types of exiting apartments, proto-type was decided. By using virtual environment Program, modeling the proto-type, compared the contribution of air temperature and the effect of outdoor air cooling. by this research, we confirmed that shaft box type balcony had many possibility for improvement of indoor environment.

A Study on Natural Ventilation by the Caloric Values of HLW in the Deep Geological Repository (지하처분장내 고준위 방사성 폐기물 발열량에 따른 자연환기력 연구)

  • Roh, Jang-Hoon;Choi, Heui-Joo;Yu, Yeong-Seok;Yoon, Chan-Hoon;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.21 no.6
    • /
    • pp.518-525
    • /
    • 2011
  • In this study, the natural ventilation pressure resulting from the large altitude difference which is a characteristic of high radioactive waste repository and the caloric value of the heat emitted by wastes was calculated and based on the results, natural ventilation quantities were calculated. A high radioactive waste repository can be considered as being operated through closed cycle thermodynamic processes similar to those of thermal engines. The heat produced by the heating of high radioactive wastes in the underground repository is added to the surrounding air, and the air goes up through the upcast vertical shaft due to the added heat while working on its surroundings. Part of the heat added by the work done by the air can be temporarily changed into mechanical energy to promote the air flow. Therefore, if a sustained and powerful heat source exists in the repository, the heat source will naturally enable continued cyclic flows of air. Based on this assumption, the quantity of natural ventilation made during the disposal of high radioactive wastes in a deep geological layer was mathematically calculated and based on the results, natural ventilation pressure of $74{\sim}183$Pa made by the stack effect was identified along with the resultant natural ventilation quantity of $92.5{\sim}147.7m^3/s$. The result of an analysis by CFD was $82{\sim}143m^3/s$ which was very similar to the results obtained by the mathematical method.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Sub-10 nm Ge/GaAs Heterojunction-Based Tunneling Field-Effect Transistor with Vertical Tunneling Operation for Ultra-Low-Power Applications

  • Yoon, Young Jun;Seo, Jae Hwa;Cho, Seongjae;Kwon, Hyuck-In;Lee, Jung-Hee;Kang, In Man
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.2
    • /
    • pp.172-178
    • /
    • 2016
  • In this paper, we propose a sub-10 nm Ge/GaAs heterojunction-based tunneling field-effect transistor (TFET) with vertical band-to-band tunneling (BBT) operation for ultra-low-power (LP) applications. We design a stack structure that is based on the Ge/GaAs heterojunction to realize the vertical BBT operation. The use of vertical BBT operations in devices results in excellent subthreshold characteristics with a reduction in the drain-induced barrier thinning (DIBT) phenomenon. The proposed device with a channel length ($L_{ch}$) of 5 nm exhibits outstanding LP performance with a subthreshold swing (S) of 29.1 mV/dec and an off-state current ($I_{off}$) of $1.12{\times}10^{-11}A/{\mu}m$. In addition, the use of the highk spacer dielectric $HfO_2$ improves the on-state current ($I_{on}$) with an intrinsic delay time (${\tau}$) because of a higher fringing field. We demonstrate a sub-10 nm LP switching device that realizes a good S and lower $I_{off}$ at a lower supply voltage ($V_{DD}$) of 0.2 V.

Inverse Hysteresis Modeling for Piezoelectric Stack Actuators with Inverse Generalized Prandtl-Ishlinskii Model (Inverse Generalized Prandtl-Ishlinskii Model를 이용한 압전 스택 액추에이터의 역 히스테리시스 모델링)

  • Ko, Young-Rae;Kim, Tae-Hyoung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.193-200
    • /
    • 2014
  • Piezoelectric actuators have been widely used in various applications because they have many advantages such as fast response time, repeatable nanometer motion, and high resolution. However Piezoelectric actuators have the strong hysteresis effect. The hysteresis effect can degrade the performance of the system using piezoelectric actuators. In past study, the parameters of the inverse hysteresis model are computed from the identified parameters using the Generalized Prandtl-Ishlinskii(GPI) model to cancel the hysteresis effect, however according to the identified parameters there exist the cases that can't form the inverse hysteresis loop. Thus in this paper the inverse hysteresis modeling mothod is proposed using the Inverse Generalized Prandtl-Ishlinskii(IGPI) model to handle that problem. The modeling results are verified by experimental results using various input signals.

The Radiation Spot Size due to Wiggler Errors in a Free-Electron Laser Oscillator

  • Nam, Soon-Kwon;Park, Y.S.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1495-1501
    • /
    • 2018
  • We have developed an extended three-dimensional free-electron laser (3D FEL) code with source-dependent expansion to calculate the intensity of the radiation field and the spot size in a free-electron laser oscillator. The effect of the wiggler field errors was evaluated for the case of a planar wiggler generated by a magnet stack with parabolic shaped pole faces by using the extended three-dimensional equations in a free-electron laser oscillator based on the proposed FEL facility which is to be operated in the far-infrared and the infrared regions. The radiation spot size due to the wiggler field errors also have been analyzed for wiggler errors of ${\Delta}B/B=0.0$, 0.03, 0.06 and 0.09% at z = 1 m and z = 2 m. The effect of the diffraction of radiation field due to the wiggler field errors of ${\Delta}B/B=0.0$ and ${\Delta}B/B=0.09%$ at 200 passes was evaluated by using the extended 3D code that we developed. The variation of the curvature of the phase front and the effect of the radiation field intensity due to the wiggler field errors were also evaluated for B = 0.5 T and B = 0.7 T with the wiggler error of ${\Delta}B/B=0.09%$ at 200 passes and the results were compared to those of without errors. The intensity of the radiation, behavior of the radiation spot size and the variation of the curvature of the phase were highly sensitive to the wiggler error of ${\Delta}B/B$ > 0.09%, but were less sensitive to the wiggler errors for ${\Delta}B/B$ < 0.09% in a free-electron laser (FEL) oscillator based on the proposed FEL facility.

Effect of Sintering aid in $LaSrTiO_3$ Ceramic Interconnector for SOFC application (SOFC용 $LaSrTiO_3$계 연결재에서 소결조제 첨가에 따른 소결특성)

  • An, YongTae;Choi, ByungHyun;Ji, MiJung;Park, SungTae;Lee, KyungJin;Hwang, HaeJin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.89.1-89.1
    • /
    • 2010
  • 본 연구는 세라믹 연결재로 사용되는 Perovskite 구조의 LSTO조성의 실제 SOFC stack 적용을 위한 소결온도를 낮출 수 있는 방법에 관해 연구하였다. SOFC 단전지에서 IC 소재는 $1300{\sim}1400^{\circ}C$에서 소결이 이루어져야만 하나 현재 사용하고 있는 LCO계 조성의 경우 $1500{\sim}1600^{\circ}C$의 높은 온도에서 소결이 이루어지며 고온에서 $Cr_2O_3$의 휘발로 인해 낮은 전기전도성을 갖는 문제점을 가지고 있다. 이러한 문제점을 해결하기 위해 IC 소재에 소결조제를 첨가하여 소결특성을 평가하였고, SEM과 XRD분석을 통하여 perovskite 단일상이 합성된 것을 확인하였다. 또한 Archimedes법을 사용하여 흡수율 및 겉기공율을 측정하였고, DC analyzer를 사용하여 전기전도도를 측정한 결과 대기분위기 $750^{\circ}C$에서 높은 값을 나타냄을 확인할 수 있었다.

  • PDF

Center Determination for Cone-Beam X-ray Tomography

  • Narkbuakaew, W.;Ngamanekrat, S.;Withayachumnankul, W.;Pintavirooj, C.;Sangworasil, M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1885-1888
    • /
    • 2004
  • In order to render 3D model of the bone, the stack of cross-sectional images must be reconstructed from a series of X-ray radiographs, served as the projections. In the case where the distance between x-ray source and detector is not infinite, image reconstruction from projection based on parallel-beam geometry provides an error in the cross-sectional image. In such case, image reconstruction from projection based on conebeam geometry must be exercised instead. This paper is devoted to the determination of detector center for SART conebeam Technique which is critically effect the performance of the resulting 3D modeling.

  • PDF