• Title/Summary/Keyword: stability phase diagram

Search Result 46, Processing Time 0.027 seconds

Studies on the Formation of Inclusion Complex between Omeprazole and $\beta$-cyclodextrin (오메프라졸과 베타-시클로덱스트린과의 포접화합물 형성에 따른 특성)

  • 소재일;이창현;이계주
    • YAKHAK HOEJI
    • /
    • v.35 no.5
    • /
    • pp.372-378
    • /
    • 1991
  • To increase the stability and bioavailability of Omeprazole(OMP), which is used newly as a proton-pump inhibitor, inclusion complex of OMP with $\beta$-cyclodextrin($\beta$-CD) was prepared by coprecipitation method and its characteristics were ascertained by means of solubility test, DSC, IR, and the accelerated stability analysis. The type of OMP inclusion complex is classified as Bs-type on phase solubility diagram, and the stoichiometric ratio of OMP: $\beta$-CD complex is 1:2 and formation constant is 80.82/mole. The solubility of the complex could be increased remarkably by complexation compare with OMP. Degradation process of both OMP and OMP complex followed apparent first-order kinetics, of which degradation rate constants and activation energies are k$_{25}$=8.1$\times$10$^{-4}$/day, E$_{a}$=22 Kcal/mole (OMP), and k$_{25}$=4.65$\times$10$^{-6}$/day, E$_{a}$=35 Kcal/mole (complex), respectively. These results show the increase of the stability and solubility of OMP markedly, therefore it is believed that the improvement of stabilization for OMP by inclusion complexation might be practically available.

  • PDF

Stability analysis of fuzzy logic controller using the concept of sector bound nonlinearity (제한된 부채꼴에서의 비선형 개념을 이용한 퍼지 논리제어기의 안정성 해석)

  • 김인익;박상배;이균경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.573-578
    • /
    • 1991
  • A stability analysis technique has been proposed for linear SISO system associated with fuzzy logic controller. An analysis technique using the concept of well-known sector bound nonlinearity and its graphical interpretation, i.e., the circle criterion, is presented. Thus the use of classical Nyquist locus and the BODE diagram is brought into the picture. The aim of this present note is to represent a graphical approach based on sector bound nonlinearity and circle criterion for assessing the performance(degree of stability) of the linear SISO system associated with fuzzy logic controller. The degree of stability of the system is defined in terms of its gain and phase margins as defined in Section 3.

  • PDF

Effect of Cyclodextrins on the Solubility and Stability of Aspalatone in Aqueous Solutions (수용액중 시클로덱스트린류가 아스팔라톤의 용해성과 안정성에 미치는 영향)

  • Gwak, Hye-Sun;Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.267-271
    • /
    • 2000
  • The effect of cyclodextrins on the solubility and stability of aspalatone (acetylsalicylic acid maltol ester, AM, CAS 147249-33-0), which has been recently found to have an antithrombotic effect, was investigated. The addition of ${\beta}-cyclodextrin\;({\beta}-CD),\;dimethyl-{\beta}-cyclodextrin\;(DMCD)\;or\;2-hydroxypropyl-{\beta}-cyclodextrin\;(HPCD)$ to the aqueous solution increased the solubility of AM concentration-dependently. From the phase solubility diagram, stability constants for $AM-{\beta}-CD$, -DMCD or -HPCD complexes were calculated to be 43.1, 78.3 and $53.0\;M^{-1}$. The addition of ${\beta}-CD$, DMCD or HPCD to AM solution retarded the degradation rate of AM in the acidic region. However, ${\beta}-CD$ and HPCD rather acted as an accelerator of degradation in the neutral and alkaline regions. DMCD had a stabilizing effect at all pHs studied.

  • PDF

A Study of Thermodynamical Reaction Path in Fe-Cr-X Alloys at High Temperature Corrosion Environments (고온 부식환경에 대한 Fe-Cr-X 합금의 열역학적 반응경로에 관한 연구)

  • Lee, Byung-Woo;Kim, Woo-Yeol
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.411-420
    • /
    • 1996
  • The structure of the scale formed on the surface of Fe - Cr - X alloys exposed to 1143K high sulfidation($Ps_2$ = 1.11$\times$$10^-7$ atm, $Po_2$ = 3.11$\times$$10^-20$ atm) or sulfidation/oxidation(($Ps_2$= 1.06$\times$$10^-7$ atm, ($Po_2$ = 3.11$\times$$10^-18$ atm) environment has been observed and analysed using XRD, SEM/EDS. To investigate the possibility of protective film formed on the surface of the alloys, Aluminium, Nickel were selected as alloying elements. Thermodynamic phase stability diagram was used to predict the reaction path of scale formed on Fe - Cr - X alloys. Parabolic rate constant($K_p$) value with 6wt% Al in Fe - 25Cr alloy decreased significantly compared with the Fe - 25Cr alloy without 6wt% Al. Since thin layer of defect free sulfide film, (Al, Cr)Sx, was formed at the alloy/scale interface. Fe - rich sulfide scale at outer layer and Cr - rich sulfide scale containing porosity at inner layer of Fe - 25Cr alloy have been observed. The reaction path for these scales could be predicted by the thermodynamic stability diagram.

  • PDF

A Study on Variation of the Dynamic Characteristic of Supply Voltage According to the Track Environment and Spatial Distribution as Driving of Urban Transits (도시철도차량의 운행 선로환경 및 공간적 분포에 따른 공급전압 동특성 변화)

  • Kim, Yang-Su;Chang, Chin-Young;Lee, Ki-Sik;Koo, Kyung-Wan;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1380-1386
    • /
    • 2012
  • It is important to consider supply voltage stability in case of design and construction of a substation at electric railway because a urban transit is operated by electricity and it is driven simultaneous in the same section. This paper study on variation of the dynamic characteristic of supply voltage according to the track environment and spatial distribution as driving of urban transits. Simulation tool, TOM(Train Operations Model) software is used to ensure stability of feeder system being used around the world. As results of simulation, voltage of the contact wire is in limits on driving operation diagram of urban transits. Also, it has confirmed that there is a correlation the phase current, depending on the speed of urban transit and track environment like vertical gradients and curve radius.

DFT Investigation of Phase Stability of Magnesium Alanate (Mg(AlH4)2) for Reversible Hydrogen Storage (가역적 수소 저장을 위한 마그네슘 알라네이트 (Mg(AlH4)2) 나노 입자 활용 : 밀도범함수이론 연구)

  • DONG-HEE LIM;EUNMIN BAE;YOUNG-SOO HAN
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.2
    • /
    • pp.169-177
    • /
    • 2023
  • Phase stability diagrams were constructed for magnesium alanate (Mg(AlH4)2) nanoparticles to investigate the reversible hydrogen storage reaction by using density functional theory. Our findings indicate that bulk Mg(AlH4)2 shows favorable hydrogen release, but unfavorable hydrogen uptake (adsorption) reactions. However, for Mg(AlH4)2 nanoparticles, it was observed that hydrogen release and recharge can be achieved by controlling the particle size and temperature. Furthermore, by predicting the decomposition phase diagram of Mg(AlH4)2 nanoparticles with varying hydrogen partial pressure, it was discovered that reversible dehydrogenation reactions can occur even in relatively large nanoparticles by controlling the hydrogen partial pressure.

Analysis of Proportional Control for Grid Connected Inverter With LCL Filter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.247-249
    • /
    • 2008
  • There are many types of grid-connected inverter controllers; Synchronous Reference Frame (SRF)-based controller is the most popular methods. SRF-based controller is capable for reducing both of zero-steady state error and phase delay. However, SRF-based controller has a complex algorithm to apply in real application such as digital processor. Resonant controller is also reduced zero-steady state error, but its transfer function has a high order. In this paper, a simple proportional control is applied for grid connected inverter with LCL filter. LCL filter is a third order system. Applying a simple proportional controller is not increased the order of closed loop transfer function. By this technique, the single phase model is easily obtained. To reduce steady state error, proportional gain is set as high as possible, but it may produce instability. To compromise between a minimum steady state error and stability, the single phase model is evaluate through Root Locus and Bode diagram. PSIM simulation is used to verify the analysis.

  • PDF

Thermodynamic Comparison of Silicon Carbide CVD Process between CH3SiCl3-H2 and C3H8-SiCl4-H2 Systems (탄화규소 CVD 공정에서 CH3SiCl3-H2과 C3H8-SiCl4-H2계의 열역학적 비교)

  • Choi, Kyoon;Kim, Jun-Woo
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.8
    • /
    • pp.569-573
    • /
    • 2012
  • In order to understand the difference in SiC deposition between the $CH_3SiCl_3-H_2$ and $C_3H_8-SiCl_4-H_2$ systems, we calculate the phase stability among ${\beta}$-SiC, graphite and silicon. We constructed the phase-diagram of ${\beta}$-SiC over graphite and silicon via computational thermodynamic calculation considering pressure (P), temperature (T) and gas composition (C) as variables. Both P-T-C diagrams showed a very steep phase boundary between the SiC+C and SiC region perpendicular to the H/Si axis, and also showed an SiC+Si region with a H/Si value of up to 6700 in the $C_3H_8-SiCl_4-H_2$, and 5000 in the $CH_3SiCl_3-H_2$ system. This difference in phase boundaries is explained by the ratio of Cl to Si, which is 4 for the $C_3H_8-SiCl_4-H_2$ system and 3 for the $C_3H_8-SiCl_4-H_2$ system. Because the C/Si ratio is fixed at 1 in the $CH_3SiCl_3-H_2$ system while it can be variable in the $C_3H_8-SiCl_4-H_2$ system, the functionally graded material is applicable for better mechanical bonding during SiC coating on graphite substrate in the $C_3H_8-SiCl_4-H_2$ system.

Refinement of Gd2O3 inclusions in the GdBa2Cu3O7-δ films fabricated by the RCE-DR process

  • Park, I.;Oh, W.J.;Lee, J.H.;Moon, S.H.;Yoo, S.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.46-49
    • /
    • 2018
  • To improve in-field critical current densities ($J_c$) of $GdBa_2Cu_3O_{7-{\delta}}$ (GdBCO) coated conductors(CCs) fabricated by the reactive co-evaporation by deposition and reaction (RCE-DR) process, employing the nominal composition of Gd:Ba:Cu=1:1:2.5, we tried to refine the $Gd_2O_3$ particles trapped in the GdBCO superconducting matrix. For this purpose, we carefully selected the processing conditions on the stability phase diagram of GdBCO for this composition. By lowering the growth temperature of $Gd_2O_3$ in the liquid, we could refine the average particle size of $Gd_2O_3$ particles trapped in the GdBCO matrix and also achieve the zero-resistive transition temperatures ($T_{c,zero}$) of 92.3~94.2 K. Unfortunately, however, it was unsuccessful to achieve enhanced in-field $J_c$ values from these samples because of an air-contamination of the amorphous precursor film before its conversion into crystalline GdBCO film, suggesting that any exposure of the amorphous precursor film to air is fatal in obtaining high performance GdBCO CCs via the RCE-DR process.

Analysis of Decoupling Method in DQ Transform-based for Grid Connected Inverter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.924-925
    • /
    • 2008
  • There are many types of grid-connected inverter controllers, PI controller based is the most popular methods. But, a common PI control is produced zero-steady state error and phase delay in sinusoidal reference. Synchronous reference frame or DQ transform based controller is capable for reducing both of zero-steady state error and phase delay is. But DQ transform based controller has cross-coupling component which difficult to analyze the system in single phase model. In this paper, to obtained single phase model of the system, DQ transform based controller is analyzed in two techniques. The first is by neglecting cross-coupling. The second is eliminated cross-coupling component by decoupling method. By these two techniques, single phase model is obtained. Then, the single phase model is analyzed to evaluate its performance in stability and frequency response, through Root Locus and Bode diagram, respectively. MATLAB and PSIM simulation is used to verify the analysis. Simulation result is shown; cross-coupling component has no significant influent to the controller.

  • PDF