• Title/Summary/Keyword: spring damper

Search Result 406, Processing Time 0.031 seconds

Instability caused by interaction between a rotating disk and a mass-spring-damper system (회전원판과 스프링-댐퍼를 가진 질점계의 상호작용에 의한 불안정성)

  • Kim, C.B;Han, D.H
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.2038-2046
    • /
    • 1997
  • In this paper the instability of the system which has a disk and a mass-spring-damper system interacting through a medium having stiffness and damping is analyzed. To solve the equations of motion of this systme, it is assumed that the solution consists of the eigenfunctions which are the products of the Bessel functions and sine or cosine functions. The former represents the radial characteristics of the disk and the latter represents the circumferential characteristics. Using this assumed solution and the orthogonality of the eigenfunctions, the equations of motion can be transformed into a set of equations of motion with variables dependent only on the time. After this set is changed to the state equation, the eigenvalue problem can be made. Once the eigenvalues are calculated according to the angular velocity of the disk, the dynamic characteristics ofthis system is obtained. Because the thickness of the disk and the element characteristics of the mass-spring-damper system have important effects on the stability of the system, it will be understood how these factors affect the system and then a method to ameliorate the stability of the system with a disk will be presented.

Effect of the sampling time of high-frequency ZOH and a physical damper on stable haptic interaction (고주파 영차홀드의 샘플링 주기와 물리적 댐퍼가 안정적인 햅틱 상호작용에 미치는 영향)

  • Lee, Kyungno
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.649-654
    • /
    • 2019
  • Stable haptic interaction with virtual environments is essential not only for the safety of the user but also for improving the immersion of the user. If the coefficient of a virtual spring is increased, the system becomes unstable. Therefore, the coefficient of the virtual spring is limited. The haptic system with the high-frequency zero-order-hold (HF-ZOH) is proposed to enhance the stability margin of a virtual spring. In this paper, the relationship among the sampling period of HF-ZOH, the coefficient of the physical damper, and the maximum stable margin of the virtual spring is analyzed. The lager the coefficient of the physical damper is, the shorter the sampling period of the HF-ZOH is, the larger the stable region of the virtual spring becomes. If the ratio N is larger than 40, the stable region of the proposed method is about three times to eight times that of the previous method, according to the coefficient of the physical damper. Hence the method enables to improve the user's realism in virtual environments.

Dynamic Characteristics of Eddy Current Damper (와전류 댐퍼의 동적특성)

  • Kwag, Dong-Gi;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.947-951
    • /
    • 2007
  • This paper is concerned with a new concept for the damper without neither a coil spring nor fluid. The new damper concept consists of the permanent magnets and the cylinder of the conducting material. The opposite pole magnets produces the repulsive forces and this is substituted for the coil spring. The relative motion between the magnets and conducting cylinder produces eddy currents thus resulting in the electromagnetic force, which turns out to be the damping force thus and is substituted for a damping fluid. This damper is called the eddy current damper(ECD). The important advantage of the proposed ECD is that it does not require the damping fluid and any external power and is non-contacting and relatively insensitive to temperature. In the present study, the proposed ECD was constructed and experiments were performed to investigate its dynamic characteristics. The experiments shows that the proposed ECD has the excellent damping ability.

  • PDF

Development of Air Spring Damper System(ASDS) (공기 스프링 댐퍼 시스템(ASDS)의 개발)

  • Kim, Dong Baek;Park, Heung Sik
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.829-838
    • /
    • 2021
  • Purpose: The Air Spring Damper System (ASDS) is proposed when existing concrete structures that have not been seismic resistant for economic and technical reasons or low-rise concrete structures that are difficult to earthquake. Method: To conduct a study on the damping force antigen in the kinetic equation of free vibration, we analyze whether this device has damping ability as a damper experimentally and theoretically, and examine the possibility of field application. Result: The air damper system is considered to be more economical than steel hysteresis dampers even if the number of dampers increases due to its easy manufacture and construction and low restrictions on shape, size, material, etc. Conclusion: In an air spring damper system, it is essential to reduce the diameter of the air inlet/outlet hole to improve the damping ratio, and in this case, if the diameter exceeds a certain lower limit, consideration of the compressibility of air is required, so further research is needed.

Comparison of semi-active and passive tuned mass damper systems for vibration control of a wind turbine

  • Lalonde, Eric R.;Dai, Kaoshan;Bitsuamlak, Girma;Lu, Wensheng;Zhao, Zhi
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.663-678
    • /
    • 2020
  • Robust semi-active vibration control of wind turbines using tuned mass dampers (TMDs) is a promising technique. This study investigates a 1.5 megawatt wind turbine controlled by eight different types of tuned mass damper systems of equal mass: a passive TMD, a semi-active varying-spring TMD, a semi-active varying-damper TMD, a semi-active varying-damper-and-spring TMD, as well as these four damper systems paired with an additional smaller passive TMD near the mid-point of the tower. The mechanism and controllers for each of these TMD systems are explained, such as employing magnetorheological dampers for the varying-damper TMD cases. The turbine is modelled as a lumped-mass 3D finite element model. The uncontrolled and controlled turbines are subjected to loading and operational cases including service wind loads on operational turbines, seismic loading with service wind on operational turbines, and high-intensity storm wind loads on parked turbines. The displacement and acceleration responses of the tower at the first and second mode shape maxima were used as the performance indicators. Ultimately, it was found that while all the semi-active TMD systems outperformed the passive systems, it was the semi-active varying-damper-and-spring system that was found to be the most effective overall - capable of controlling vibrations about as effectively with only half the mass as a passive TMD. It was also shown that by reducing the mass of the TMD and adding a second smaller TMD below, the vibrations near the mid-point could be greatly reduced at the cost of slightly increased vibrations at the tower top.

Effects of a First-order-hold Method and a Virtual Damper on the Stability Boundary of a Virtual Spring (일차홀드 방식과 가상 댐퍼가 가상 스프링의 안정성 영역에 미치는 영향)

  • Lee, Kyungno
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.396-401
    • /
    • 2019
  • A virtual rigid is modeled as the parallel structure of a virtual spring and a virtual damper. The reflective force from the virtual model is designed to be as large as possible to improve the realism of the virtual environment while maintaining the stable interaction. So, it is important to analyze the stability boundary of the virtual spring and damper. In the previous researches, the stability boundary is analyzed based on the zero-order-hold (ZOH) method, but it is analyzed based on the first-order-hold (FOH) method and the virtual damper in the paper. The boundary value of the stable virtual damper is inverse proportional to the sampling time and the maximum value of stable virtual stiffness is inverse proportional to the square of the sampling time. And the maximum value in the FOH method is increased to 110% of the value in the ZOH method. If the virtual damper is smaller than about 50% of the boundary value of the virtual damper in the FOH method, the stable virtual stiffness in the FOH method is several times larger than that in the ZOH method.

Parametric study of a new tuned mass damper with pre-strained SMA helical springs for vibration reduction

  • Hongwang Lv;Bin Huang
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.89-100
    • /
    • 2023
  • This paper conducts a parametric study of a new tuned mass damper with pre-strained superelastic SMA helical springs (SMAS-TMD) on the vibration reduction effect. First, a force-displacement relation model of superelastic SMA helical spring is presented based on the multilinear constitutive model of SMA material, and the tension tests of the six SMA springs fabricated are implemented to validate the mechanical model. Then, a dynamic model of a single floor steel frame with the SMAS-TMD damper is set up to simulate the seismic responses of the frame, which are testified by the shaking table tests. The wire diameter, initial coil diameter, number of coils and pre-strain length of SMA springs are extracted to investigate their influences on the seismic response reduction of the frame. The numerical and experimental results show that, under different earthquakes, when the wire diameter, initial coil diameter and number of coils are set to the appropriate values so that the initial elastic stiffness of the SMA spring is between 0.37 and 0.58 times of classic TMD stiffness, the maximum reduction ratios of the proposed damper can reach 40% as the mass ratio is 2.34%. Meanwhile, when the pre-strain length of SMA spring is in a suitable range, the SMAS-TMD damper can also achieve very good vibration reduction performance. The vibration reduction performance of the SMAS-TMD damper is generally equal to or better than that of the classic optimal TMD, and the proposed damper effectively suppresses the detuning phenomena that often occurs in the classic TMD.

Analysis of a Variable Damper and Pneumatic Spring Suspension for Bicycle Forks using Hydraulic-Pneumatic Circuit Model (유공압 회로를 이용한 자전거 포크용 가변댐퍼-공압스프링 서스펜션의 해석)

  • Chang, Moon Suk;Choi, Young Hyu;Kim, Su Tae;Choi, Jae Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.7-13
    • /
    • 2019
  • The objective of this study was to present a damped pneumatic suspension, a bike fork suspension, which can adapt itself to incoming road excitations is presented in this paper. It consists of a hydraulic damper and a pneumatic spring in parallel with a linear spring. The study also proposed a variable and switchable orifice, in the hydraulic damper, to select appropriate damping property. Hydraulic-pneumatic circuit model for the bike fork suspension was established based on AMESim, in order to predict its performance. In addition, elastic-damping characteristics of the fork such as spring constant and viscous damping coefficient were computed and compared, for validation, with those evaluated by experiment using the universal test machine. Through simulation analysis and test, it was established that the hydraulic-pneumatic circuit model is effective and practical for development of future MTB suspensions.

Operating Vibration Reduction Effect Evaluation of EDG at the NPP Site (원자력발전소 비상디젤발전기의 가동중 진동저감 효과)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.111-118
    • /
    • 2006
  • The Emergency Diesel Generator(EDG) is a very important piece of equipment for the safety of a Nuclear Power Plant(NPP). In this study, the operating vibration or three kinds or EDG system was measured. The target EDG systems art Yonggwang 5 unit, Ulchin 2 unit and Ulchin 3 unit. The Yonggwang 5 and Ulchin 3 unit EDG system is the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of this measurement is for a verification of the vibration isolation effect according to the foundation system. As a result. it can he said that the spring and viscous damper system of the EDG performed well for the vibration isolation.

  • PDF

Analysis of the Dynamic Characteristics of the In-Arm Type Hydropneumatic Suspension Unit (암 내장형 유기압 현수장치의 동특성 해석)

  • Lee, H.W.;Jo, J.R.;Lee, J.K.;Jang, M.S.;An, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.519-524
    • /
    • 2003
  • In this paper we discuss the dynamic characteristics of the in-arm type hydropneumatic suspension unit(ISU). For this, two accurate models are introduced. The first one is the Benedict-Webb-Rubin equation which is adopted for the spring behavior of a real gas. This equation is applicable for the high pressure of the nitrogen gas which acts as a spring in ISU system. The second one describes the behavior of a damper, which is divided into four parts - jounce-loading, jounce-unloading, rebound-loading and rebound-unloading. This approach gives a good approximation of the real damper system. For the comparison purpose, the numerical results of the dynamic behavior of ISU system using a real gas and an ideal gas are given in the paper.

  • PDF