• Title/Summary/Keyword: sprayed air

Search Result 156, Processing Time 0.033 seconds

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

A Study on the Effect of Atomization of Pressure Nozzle with Blower - Air (압력식 노즐에서 송풍공기가 미립화에 미치는 영향에 관한 연구)

  • Koh, Kyoung-Han;Lim, Sang-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.5
    • /
    • pp.283-288
    • /
    • 2012
  • This study was undertaken to investigation the spray characteristics of the twin fluid atomization nozzle system. The light oil was injected at the normal temperature and injection pressure was 5 bar - 10 bar by 1 bar and volume flow was 0.5, 1.0 and 2,0 mmH2O(X10-2). We measured the SMD of sprayed droplet to study spray characteristics. The following conclusions were reached from the results of these study. 1. The more injection pressure increased, the more SMD decreased. 2. The more measuring distance between pressure nozzle tip and analyser beam increased, the more SMD increased. 3. SMD of the blower-air-added injection system were shown, increasing volume flow decreased respectively. The result of this study indicated the blower-air-added injection system induced beneficial changes in SMD. And it will be considered important indicator for spray characteristics design and performance evaluation of twin fluid atomization nozzle system.

Air Pollution Protection onboard by Seawater and Electrolyte

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 2006
  • This research makes a new attempt to apply the activated seawater by electrolysis in the development of two-stage wet scrubber system to control the exhaust gas of large marine diesel engines. First, with using only seawater that is naturally alkaline (pH typically around 8.1). the $SO_2\;and\;SO_3$ are absorbed by relatively high solubility compared to other components of exhaust pollutants, and PM (Particulate Matter) is removed through direct contact with sprayed seawater droplets. Besides, the electrolyzed alkaline seawater by electrolysis, which contains mainly NaOH together with alkali metal ions $(i.e.\;Na^+,\;Mg^{2+},\;Ca^{2+})$, is used as the absorption medium of NOx and $CO_2$. Especially, to increase NOx absorption rate into the alkaline seawater. nitric oxide (NO) is adequately oxidized to nitrogen dioxide $(NO_2)$ in the acidic seawater, which means both volume fractions are adjusted to identical proportion. The results found that the strong acidic seawater was a valid oxidizer from NO to $NO_2$ and the strong alkaline seawater was effective in $CO_2$ absorption In the scrubber test, the SOx reduction of nearly $100\%$ could be achieved and also led to a sufficientPM reduction. Hence, the author believes that applying seawater and its electrolyte would bring the marine air pollution control system to an economical measure. Additionally it is well known that NOx and SOx concentration has a considerable influence on the $N_2O$ emission of green house gas. Although the $N_2O$ concentration exhausted from diesel engines is not as high, the green house gas effect is around 300 times greater than an equivalent volume of $CO_2$. Therefore, we investigated the $N_2O$ removal efficiency with using the electrolyzed seawater too. Finally this research would also plan to treat the effluent by applying electro-dialysis and electro-flotation technique s in the future.

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.

Experimental Validation on Performance of Waste-heat-recovery Boiler with Water Injection (물분사 폐열회수 보일러의 효용성에 대한 실험적 검증)

  • Jaehun Shin;Taejoon Park;Hyunseok Cho;Junsang Yoo;Seoksu Moon;Changeon Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The waste-heat-recovery boiler with water spray (HR-B/WS) applies the heat exchange between the inlet air and exhaust gas with the water spray into the inlet air. The evaporation of water in the inlet air promotes heat recovery from the exhaust gas so that thermal efficiency can be improved by the enhanced condensing effect. The NOx emission can also be reduced by lowering the flame temperature due to the dilution effect of the water. In this study, the validity of this concept is examined by the practical boiler test performed with a 24 kW condensing boiler under the full load condition according to the water injection amount. The theoretical amount of water injection is calculated under the assumption of full evaporation of the sprayed water, which is calculated as 50 g/min. Since the injected water cannot evaporate fully in the actual system, the maximum water spray amount is set as 100 g/min. The results showed that the water injection can increase the thermal efficiency up to 95.59% and reduce NOx and CO emissions simultaneously to 8.9 ppm and 35 ppm at 0% of O2. Although the heat energy loss increased due to the unevaporated water, the increase in water injection amount caused higher thermal efficiency due to the increased amount of the evaporated water.

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan (터보 팬 2류체 노즐로 구성한 포그 분무장치를 이용한 온실 내 공기의 냉각 효과)

  • Kim, Tae-Kyu;Min, Young-Bong;Kim, Do-Wan;Kim, Myung-Kyu;Moon, Sung-Dong;Chung, Tae-Sang
    • Journal of agriculture & life science
    • /
    • v.46 no.3
    • /
    • pp.119-127
    • /
    • 2012
  • For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Humidification of Air Using Water Injector and Cyclonic Separator (관 내 삽입 인젝터와 사이클론을 이용한 공기 가습)

  • Kim, Beom-Jun;Kim, Sung-Il;Byun, Su-Young;Kim, Min-Soo;Kim, Hyun-Yoo;Kwon, Hyuck-Ryul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.491-498
    • /
    • 2010
  • Humidification of PEM fuel cells is necessary for enhancing their performance and lifetime. In this study, a humidification system was designed and tested; the system includes an air-supply tube (inner diameter: 75 mm) through which a nozzle can be directly inserted and a cyclonic separator for the removal of water droplets. Three types of nozzles were employed to study the influence of injection pressure, air flow rate, and spray direction on the humidification performance. To evaluate the humidification performance, the concept of humidification efficiency was defined. In the absence of an external heat source, latent heat for evaporation will be supplied by the own enthalpies of water and air. Thus, the amount of water sprayed from the nozzle is the most critical factor affecting the humidification efficiency. Water droplets were efficiently removed by a cyclonic separator, but re-entrainment occurred at high air flow rates. The absolute humidity and humidification efficiency were $21.29\;kJ/kg_{da}$ and 86.57%, respectively, under the following conditions: nozzle type PJ24; spray direction angle $90^{\circ}$; injection pressure 1200 kPa; air flow rate 6000 Nlpm.

Application of Gaseous Ozone for Cleaning Biological Weapon Agent Contaminated Building (생물테러시 실내제독을 위한 효율적인 오존가스의 적용 방법)

  • Yoon, Je-Yong;Jeong, Woo-Dong;Mun, Sung-Min;Cho, Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.101-108
    • /
    • 2008
  • This study attempted to develop the technology by gaseous ozone for decontaminating building affected by a model of biological weapon agent(Bacillus subtilis spores) instead of Bacillus anthracis spore. The use of ozone is attractive method from a practical point of view of decontamination procedure since it has strong oxidation power but no residue after application. We examined the disinfection efficiency of gaseous ozone to Bacillus subtilis spores which suspension was sprayed on different material surfaces and dried. Three different types of gaseous ozone was applied : dry ozone, dry ozone with humidified air, and water bubbled wet ozone. Dry ozone(1500ppm) failed to achieve any significant inactivation for 2hrs. However, six log reduction of B. subtilis spore was achieved within 30min by 1500ppm of water bubbled wet ozone. This result shows the noticeable inactivation efficiency by gaseous ozone compared with previous studies. Good performance by wet ozone was also found for military material surface.(i.e. : gas mask hood, protective garments, army peinted metal surface).

Codoped ZnO films by a co-spray deposition technique for photovoltaic applications

  • Zhou, Bin;Han, Xiaofei;Tao, Meng
    • Advances in Energy Research
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2014
  • A co-spray deposition technique has been developed to bypass a fundamental limitation in the conventional spray deposition technique, i.e., the deposition of metal oxides from incompatible precursors in the starting solution. With this technique, ZnO films codoped with F and Al have been successfully synthesized, in which F is incompatible with Al. Two starting solutions were prepared and co-sprayed through two separate spray heads. One solution contained only the F precursor, $NH_4F$. The second solution contained the Zn and Al precursors, $Zn(O_2CCH_3)_2$ and $AlCl_3$. The deposition was carried out at $500^{\circ}C$ on soda-lime glass in air. A minimum sheet resistance, $55.4{\Omega}/{\square}$, was obtained for Al and F codoped ZnO films after vacuum annealing at $400^{\circ}C$, which was lower than singly-doped ZnO with either Al or F. The transmittance for the codoped ZnO samples was above 90% in the visible range. This co-spray deposition technique provides a simple and cost-effective way to synthesize metal oxides from incompatible precursors with improved properties for photovoltaic applications.