Browse > Article

Cooling Effect of Air in Greenhouse Using A Fog Sprayer Consisted of Two-fluid Nozzle with Turbo Fan  

Kim, Tae-Kyu (Dept. of Machinery Eng., Gyeongnam Nat'l Univ. of Science and Technology)
Min, Young-Bong (Dept. of Bio-Industrial Machinery Eng., Gyeongsang Nat'l Univ.(Insti. of Agric. & Life Sci.))
Kim, Do-Wan (Dept. of Bio-Industrial Machinery Eng., Gyeongsang Nat'l Univ.(Insti. of Agric. & Life Sci.))
Kim, Myung-Kyu (Dept. of Machinery Eng., Gyeongnam Nat'l Univ. of Science and Technology)
Moon, Sung-Dong (Dept. of Industrial & Management Eng., Kangwon Nat'l Univ.)
Chung, Tae-Sang (Dept. of Machinery Eng., Gyeongnam Nat'l Univ. of Science and Technology)
Publication Information
Journal of agriculture & life science / v.46, no.3, 2012 , pp. 119-127 More about this Journal
Abstract
For the promotion of the evaporative cooling efficiency of hot air in greenhouse in summer, a fog sprayer consisted of a high volume spraying two-fluid nozzle with turbo fan and a blowing fan was set up at 2.2 m height from bottom of small glass greenhouse and tested to estimate the possibility of the greenhouse cooling. The mean droplet size and the volume sprayed by one of fog sprayer were $29{\mu}m$ and $160m{\ell}/min$. All the droplets sprayed and blown by the fog sprayer were evaporated within 2 m radius. The result from the cooling test that two sprayers set up in glass greenhouse of plane area $228m^2$ was represented lower cooling effect that the temperature and relative humidity of inside air of greenhouse were $28.8^{\circ}C$ and 87.5% when those of outside air of greenhouse were $30.2^{\circ}C$ and 81.2%. Through investigation of literatures and results of the cooling test, it was estimated that the water spraying rate of evaporative cooling of single span greenhouse with 50% light curtain and with air change rate of 1 volume/min was $10m{\ell}/min/m^2$ so that the inside air temperature may cool down $2{\sim}3^{\circ}C$ on the basis of $35^{\circ}C$ atmospheric temperature in summer of south korean area.
Keywords
Two-fluid nozzle; Greenhouse cooling; Spray system; Evaporative cooling;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kim, Y. B., H. S. Sung, N. K. Yun, S. Y. Lee, S. J. Hwang, H. T. Kim, and J. P. Lee. 2011. Effects of the open level of the side window on the control of the temperature and relative humidity in the fog cooling greenhouse. J. Agric. Life Sci. 45: 265-278.
2 Kim, K. S., M. K. Kim, and I. H. Yu. 1999. Actual state of paractical use and effect of evaporative cooling system. J. Bio-Environ. Cont. 8: 281-287.
3 Kim, Y. J., Y. S. Yoo, J. H. Yun, K. Y. Oh and S. H. Kim. 1997. Fog nozzle-greenhouse cooling system analysis. Proceedings of the KSAM '97 Winter Conference, the Korean Society for Agricultural Machinery 2: 233-242.
4 Kim, M. G. and Y. B. Min. 1994. On the atomization characteristics of twin fluid nozzles for cold fog machine(2). -on the atomization and spraying performance of five kinds of twin fluid nozzles-. Proceedings of Korea Conference on Liquid Atomization and Spray systems '94, ILASS-Korea. pp.110-123.
5 Moon S. D., Y. B. Min and D. W. Kim. 2006. Evaporation characteristics of droplets sprayed by two-fluid nozzle with turbo fan. J. Agric. Life Sci. 40: 49-54.
6 Nam, S. W. 1998. Adaptability of evaporative cooling system for greenhouse to the weather conditions of korea, J. Biol. Prod. Facilities Environ. Cont. 7: 283-289.
7 남상운. 1996. 온실냉방기술의 현황 및 과제, 제3회 한국첨단농업시설협의회 정기총회 연구발표. (사)한국첨단농업시설협의회 발행. pp. 57-88.
8 민영봉. 2000. 증발냉각에 의한 냉방효과와 적합설비. 시설원예의 고온기 냉방관리 기계기술 세미나, 농촌진흥청 농업기계화연구소 주최. pp. 31-68.
9 서원명, 민영봉, 박중춘. 1994. 온실의 냉방관리를 위한 기화냉각 시스템 도입. 시설원예연구 vol.1. 경상대학교 시설원예연구소. pp. 173-178.
10 최영하, 엄영철. 1999. 고온기 유리온실의 냉방방법별 냉방효과 구명. 시설원예연구 12: 59-65.