• 제목/요약/키워드: sport shoe

검색결과 76건 처리시간 0.015초

유선형 후방 밸런스 신발과 일반 신발의 족저압 비교 (The Plantar Pressure Comparison between the Curved Rear Balance Shoes and Normal Shoes)

  • 김연정;채원식
    • 한국운동역학회지
    • /
    • 제17권3호
    • /
    • pp.173-180
    • /
    • 2007
  • The purpose of study was to compare plantar pressure during walking wearing the curved rear balance and normal shoes. Twelve university students(height: $177.2{\pm}4.6cm$, weight: $68.4{\pm}5.8kg$, age: $26.2{\pm}1.6yrs.$) who have no known musculoskeletal disorders were recruited as the subjects. Plantar foot pressures were evaluated using the Tekscan's pressure measurement systems while subjects walked upright position wearing the curved rear balance and normal shoes in random order at a speed of 1.3 m/s. The contacting dimension, the mean plantar pressure, and the peak plantar pressure were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). As a result, the curved rear balanced shoes showed as large as 38 up to 50 % of area at the rear side of feet than the normal shoes when measuring the contact area with upright position. In the distribution of average pressure, the curved rear balanced shoes displayed fairly low pressure compared to other normal shoes in general except for one area, which is M2, and especially, the measured pressures at the both rear (M1) and middle (M5) side of feet were low and statically significant. The contact area of the curved rear balanced shoes when walking was significantly larger at the rear (M1) and fore (M6, M7) side of feet. When considering pressure distribution at walking, low pressure was detected at the rear side of feet with the curved rear balanced shoes and at the fore side of feet for other normal shoes. The results showed that the contacting dimension of the curved rear balance shoes that acts between shoes and feet was higher than the corresponding value for the normal shoes in general; therefore it would reduce the pressure to the feet by allowing the each sole of the foot on the ground evenly.

정상의 발과 병적인 발에서 발보조기 연구의 비판적 고찰 (A Critical Review of Foot Orthoses in Normal and Diseased Foot)

  • 김승재;김장환;탁계래;배상우;박영기
    • 한국운동역학회지
    • /
    • 제17권3호
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this study was to critically review biomechanical studies on foot orthoses (FO) in normal and diseased foot and provide beneficial information obtained from researches until now and future researching focus. The search was performed by Medline and Embase database including studies published in English from January 1980 to April 2007. The searching terms were foot orthoses, foot orthotics, insoles and shoe insert. 57 studies including 54 journal articles and 3 abstracts were finally selected under the conditions of having clinical trials, FO, control condition, movement, scientific measuring system. The reviewed studies were divided into 10 categories according to subject characteristics; healthy normal, excessive pronation or flexible flat foot, rheumatoid arthritis, diabetes, medial knee osteoarthritis, forefoot varus, plantar fasciitis, patellofemoral syndrome, cavus foot and finite element model. In summary, first, soft and semirigid FOs with some degree of cushioning showed much higher comfort and efficacy than rigid FO. Second, no big differences between prefabricated and custom FO were shown. Third, the full length's FO was preferable to the half length's FO or simple arch supports. Fourth, the wearing of FO combining medial arch supports and metatarsal dome made positive roles to enhance comfort and functionality and redistribute plantar pressure under the foot. Fifth, for patients with knee-related diseases lateral wedges were preferable. Sixth, measuring systems were properly applied according to the types of foot diseases.

TiO2-containing nanocomposite structure: Application and investigation in shoes sports medical soles in physical activities

  • Xufei Li;H. Elhosiny Ali;Ibrahim Albaijan
    • Advances in nano research
    • /
    • 제15권4호
    • /
    • pp.329-337
    • /
    • 2023
  • Wearing the right sportswear is one of the essential points in exercising, which is mainly neglected. Sportswear should be suitable for the ambient temperature and not cause more heat or cold in the athlete's body. On the other hand, increased sweating and blood circulation during exercise should not cause fatigue or heatstroke in the athlete. Nanotechnology has grown significantly in the field of producing more efficient equipment in the field of sports. The increase in demand in sports for complete sports equipment has revealed the necessity of using the highest quality materials in this sector. In the world of championship sports, a minor change in equipment can lead to significant changes in causing failure and victory. Since the sole is the most critical part of sports shoes, with the introduction of nanotechnology and nanocomposites, it is possible to help athletes rush and increase their sense of calm and satisfaction. Using nanocomposites in the soles of shoes can improve some of their characteristics, prevent the smell and sweat of shoes, and induce water repellency in these shoes. In this research, titanium dioxide (TiO2) nanocomposite, along with cellulose, has been used to create antibacterial and hydrophobic properties in the soles of sports shoes. The synthesized nanocomposite has been synthesized using the least amount of chemicals, which shows this method's easy and cost-effective synthesis.

Differences in the Joint Movements and Muscle Activities of Novice according to Cycle Pedal Type

  • Seo, Jeong-Woo;Kim, Dae-Hyeok;Yang, Seung-Tae;Kang, Dong-Won;Choi, Jin-Seung;Kim, Jin-Hyun;Tack, Gye-Rae
    • 한국운동역학회지
    • /
    • 제26권2호
    • /
    • pp.237-242
    • /
    • 2016
  • Objective: The purpose of this study was to compare the joint movements and muscle activities of novices according to pedal type (flat, clip, and cleat pedal). Method: Nine novice male subjects (age: $24.4{\pm}1.9years$, height: $1.77{\pm}0.05m$, weight: $72.4{\pm}7.6kg$, shoe size: $267.20{\pm}7.50mm$) participated in 3-minute, 60-rpm cycle pedaling tests with the same load and cadence. Each of the subject's saddle height was determined by the $155^{\circ}$ knee flexion angle when the pedal crank was at the 6 o'clock position ($25^{\circ}$ knee angle method). The muscle activities of the vastus lateralis, tibialis anterior, biceps femoris, and gastrocnemius medialis were compared by using electromyography during 4 pedaling phases (phase 1: $330{\sim}30^{\circ}$, phase 2: $30{\sim}150^{\circ}$, phase 3: $150{\sim}210^{\circ}$, and phase 4: $210{\sim}330^{\circ}$). Results: The knee joint movement (range of motion) and maximum dorsiflexion angle of the ankle joint with the flat pedal were larger than those of the clip and cleat pedals. The maximum plantarflexion timing with the flat and clip pedals was faster than that of the flat pedal. Electromyography revealed that the vastus lateralis muscle activity with the flat pedal was greater than that with the clip and cleat pedals. Conclusion: With the clip and cleat pedals, the joint movements were limited but the muscle activities were more effective than that with the flat pedal. The novice cannot benefit from the clip and cleat pedals regardless of their pull-up pedaling advantage. Therefore, the novice should perform the skilled pulling-up pedaling exercise in order to benefit from the clip and cleat pedals in terms of pedaling performance.

트레드밀 보행시 인솔 형태 변화에 따른 족저압력 분석 (Analysis of Plantar Foot Pressure according to Insole Types during Treadmill Gait)

  • 우정휘;이중숙;양정옥;이범진;배강호;한동욱;박상묵;배진우
    • 한국운동역학회지
    • /
    • 제25권1호
    • /
    • pp.113-122
    • /
    • 2015
  • Objective : The purpose of this study was to analyze the foot-pressure distribution of 2D(2 dimensional form) & 3D(3 dimensional form; a customized arch-fit for posture correction) insoles for assessing their biomechanical functionality. Background : Recently there has been increased interest in both foot health and foot pain patients. Analysis of the plantar pressure was often used to solve the problems of the foot displayed by such people as rheumatoid arthritis patients. Method : Subjects who participated in this study were 17 female university students who had no previous injury experience in lower limbs and a normal gait pattern. The shoe size of all subjects was 240 mm. Two models of insoles of 2D(typical flat insole - 2 dimensional form) and 3D(special production - 3 dimensional form) were selected for the test. Using the Pedar-X system and Pedar-X insoles, 4.0 km/h of walking speed, and a compilation of 50 steps walking stages were used to analyze foot-pressure distribution. Results : Results of the foot-pressure distribution and biomechanical functionality on each insole were as follows; analyses of mean plantar pressure, maximum plantar pressure, maximum vertical GRF, and plantar pressure curve shape all showed overall low plantar pressure and GRF. Conclusion : This can be evaluated as an excellent insole for low levels on the plantar pressure and GRF. Therefore, it is possible to conclude that according to this analysis the 3D Customized Arch-fit Insole was better than 2D insole on the basis of these criteria.

가속도계를 이용한 보행 시점 검출 알고리즘 개발 (Development of Gait Event Detection Algorithm using an Accelerometer)

  • 최진승;강동원;문경률;방윤환;탁계래
    • 한국운동역학회지
    • /
    • 제19권1호
    • /
    • pp.159-166
    • /
    • 2009
  • 본 연구의 목적은 실외 보행 실험 시 사용하기에 간편한 가속도계를 이용하여 보행 이벤트를 자동으로 검출하는 알고리즘을 개발하고 검증하는 것이다. 개발된 알고리즘은 신발의 발등에 부착된 3축 가속도계의 가속도의 총합과 보행 진행 방향(x축) 가속도를 이용하였다. 가속도 총합은 착지 시점의 검출에, x축 가속도는 이지 시점의 검출에 각각 사용되었다. 7명의 피험자가 느린 보행 속도 선호 보행 속도 빠른 보행 속도로 보행 실험을 수행하였고, 개발된 알고리즘의 검증을 위해 지면반력기를 포함한 3차원동작분석시스템과 동시에 실시되었다. 지면반력기를 이용한 보행 시점을 기준으로, 기존에 발표된 동작 자료만을 이용한 알고리즘을 통하여 얻어진 보행 시점도 함께 비교 하였다. 그 결과, 고안된 알고리즘의 정확도는 지면반력기를 이용한 값에 평균, 착지시점은 $22.33{\pm}17.45ms$, 이지시점은 $26.82{\pm}14.78ms$의 차이가 났고, 그 오차의 패턴이 일관적으로 20ms가량 먼저 검출되는 경향이 있었다. 일반적으로 트레드밀 실험에서 많이 사용되는 동작데이터를 통한 보행 시점의 비교에서도 크게 차이를 보이지 않았다. 그러므로 개발된 알고리즘은 실외 실험의 보행 시점 검출에 이용할 수 있을 것으로 판단된다. 추후 연구로는 현재의 가속도계만으로 보행 시점뿐 만아니라, 중력가속도 성분을 제거하여 보행 공간변인의 추출이 필요할 것이다.