• Title/Summary/Keyword: spectrometry (ICP-MS)

Search Result 174, Processing Time 0.03 seconds

Iodine Concentrations in Commercial Milks and Bulk Tank Milks of Dairy Farms Performed Different Teat Dipping Methods (젖소 목장의 유두침지소독 방법에 따른 집합유와 시판 우유 내 요오드 농도)

  • Jeong, Jihyeok;Kim, Danil;Kim, Doo
    • Journal of Veterinary Clinics
    • /
    • v.33 no.5
    • /
    • pp.274-277
    • /
    • 2016
  • To determine the concentrations of commercial milks and the effect of different teat dipping methods on iodine concentrations of bulk tank milk, iodine concentration was analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The 59 bulk tank milk samples were collected. The 8 brands of commercial whole milk and 5 brands of commercial organic milk were purchased. The iodine concentrations of bulk tank milks of 59 dairy farms were in the range from 42.7 to $562.5{\mu}g/L$. The iodine levels of 4 different teat dipping methods with pre-dipping, post-dipping, pre & post-dipping, and non-dipping were $138.9{\pm}41.1$, $200.6{\pm}106.9$, $205.1{\pm}93.2$, and $110.9{\pm}70.4{\mu}g/L$, respectively. No significant difference (P > 0.05) was observed among 4 different teat dipping methods. Iodine concentrations of commercial whole milks were in the range from 149.1 to $210.4(178.8{\pm}22.0){\mu}g/L$, and iodine concentrations of commercial organic milks were in the range from 85.0 to $356.9(214.2{\pm}123.3){\mu}g/L$. Iodine concentrations of commercial milk in Korea are relatively low comparing with those of other countries.

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

EFFECT OF METAL CONTACT ON THE CZT DETECTOR PERFORMANCE

  • Park, Se-Hwan;Park, Hyung-Sik;Lee, Jae-Hyung;Kin, Han-Soo;Ha, Jang-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.65-68
    • /
    • 2009
  • Metal-semiconductor contact is very important for the operating property of semiconductor detector. $Cd_{0.96}$ $Zn_{0.04}$ Te semiconductor crystal was grown with Bridgman method, and the crystal was cut and polished. EPMA (Electron Probe Micro Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometry) analysis were done to obtain the chemical composition and impurity of the crystal. Metal contact was deposited with thermal evaporator on both sides of the crystal. Detectors with Au/CZT/Au and In/CZT/Au structure were made, and I-V curve and the energy spectrum were measured with the detectors. It could be seen that the detector with the In/CZT/Au structure has superior property than the detector with Au/CZT/Au structure when the crystal resistivity was low. However, the metal contact structure effect becomes low when the crystal resistivity was high.

Distribution of Rare Earth Elements and Their Applications as Tracers for Groundwater Geochemistry - A Review

  • Hwang, Heejin;Nyamgerel, Yalalt;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • v.42 no.4
    • /
    • pp.383-389
    • /
    • 2021
  • Several studies investigating the behavior and environmental distribution of rare earth elements (REEs) have been reviewed to determine the geochemical processes that may affect their concentrations and fractionation patterns in groundwater and whether these elements can be used as tracers for groundwater-rock interactions and groundwater flow paths in small catchments. Inductively coupled plasma-mass spectrometry (ICP-MS), equipped with an ultrasonic nebulizer and active-film multiplier detector, is routinely used as an analytical technique to measure REEs in groundwater, facilitating the analysis of dissolved REE geochemistry. This review focuses on the distribution of REEs in groundwater and their application as tracers for groundwater geochemistry. Our review of existing literature suggests that REEs in ice cores can be used as effective tracers for atmospheric particles, aiding the identification of source regions.

A Study of Analytical Method for Trace Metal Ions in Whole Blood and Urine by Inductively Coupled Plasma-Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 혈액 및 소변중 미량금속의 분석에 관한 연구)

  • Lee, Won;Hur, Young-Hoe;Park, Kyung-Su
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.281-291
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in blood and urine has been investigated by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Microwave oven was used for the pretreatment of blood samples using nitric acid and hydrogen peroxide in a closedvessel digestion system with 1 mL whole blood for 8 minutes. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Detection limits for Cu, Sn, and Bi by this method were 0.000375 ng/mL, 0.000297 ng/mL, and 0.000174 ng/mL, respectively. Recoveries of 99.1% for Cu, 102.5% for Sn, and 98.4% for Bi were obtained for the standard spiked NIST SRM 955a blood sample. The developed method was applied for whole real blood and urine samples.

  • PDF

Safety Profile Assessment and Identification of Volatile Compounds of Krill Eupausia superba Oil and Residues Using Different Extraction Methods

  • Haque, A.S.M. Tanbirul;Kim, Seon-Bong;Lee, Yang-Bong;Chun, Byung-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.2
    • /
    • pp.159-165
    • /
    • 2014
  • In this study, Krill Eupausia superba oil was extracted using different solvents and supercritical carbon dioxide (SC-$CO_2$). During SC-$CO_2$ extraction, the pressure was set at 40 MPa and temperatures ranged from $40^{\circ}C$ to $55^{\circ}C$. We examined the differences in volatile compounds and safety profiles among extraction methods. Volatile compounds were determined using the thermal desorption system integrated with gas chromatography-mass spectrometry (GC-MS). Heavy metal content was analyzed by inductively coupled plasma mass spectrometry (ICP-MS). According to our results 10 volatile compounds were identified in krill sample. After SC-$CO_2$ extraction of oil, the concentrations of volatile compounds decreased, but increased after solvent extraction. In krill, heavy metal concentrations remained within the permissible limit. Moreover, Zn and Fe which have health benefits were detected at high concentrations. During a 90 days storage period at different temperatures, microbial activity was found to be lowest in SC-$CO_2$ extracted residues. Thus, the quality of krill oil and the residues obtained using SC-$CO_2$ extraction was higher and the oil was safer than those obtained using conventional solvent extraction. These results can be applied to the food industry to maintain high quality krill products.

Review of the Gross Alpha for Characterization of Radioactive Waste (방사성폐기물 특성평가를 위한 전알파 분석법 고찰)

  • Kim, Hyuncheol;Lim, Jong-Myoung;Jang, Mee;Park, Ji-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.227-235
    • /
    • 2020
  • In this study, we discussed the limitations of gross alpha measurements for the characterization of radioactive wastes produced in nuclear facilities through experimental tests and Monte Carlo N-particle transport simulations. The determination of gross alpha is essential for the disposal of radioactive waste produced in nuclear facilities in Korea. The measurements of gross alpha are easy to perform and yield rapid analytical results, but it cannot be used for quantitative analysis. The error of counting efficiency for gross alpha with various masses of the deposit on planchets using KCl and 241Am was determined. The relative deviation of the counting efficiency in samples having the same mass was 20%. Uranium was extracted from the soil through acid leaching and extraction chromatography, and the concentration of U determined by inductively coupled plasma-mass spectrometry (ICP-MS) was compared with the results for gross alpha. The gross alpha was underestimated by 50% compared to the U concentration by ICP-MS. The counting efficiency depended on the energy from the alpha emitters, which differed by up to three times in determination of the counting efficiency depending on the kinds of alpha radionuclides of interest. Therefore, the gross alpha is not compatible with the sum of radioactivity for each alpha emitter and is suitable as a screening method.

Analysis of $^{99}Tc$ and Its Activity Level in the Korean Soil (한국 토양의 $^{99}Tc$ 분석 및 방사능 농도 준위)

  • Lee, Chang-Woo;Chung, Kun-Ho;Cho, Young-Hyun;Kang, Mun-Ja;Lee, Wan-No;Kim, Hee-Reyoung;Choi, Geun-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • An analytical method of $^{99}Tc$ concentration in soil was set up and discussed considering the $^{99}Tc$ concentration in Korean soil measured with its analytical method. A selective TEVA resin was used to separate and purify the $^{99}Tc$ in the soil sample. $^{99m}Tc$ from a commercial $^{99}Mo/^{99m}Tc$ generator was used as a yield tracer for the chemical separation of $^{99}Tc$ and its problem when using $^{99m}Tc$ as a tracer was discussed. The chemical recovery yield of $^{99}Tc$ was above 70%. The optimum conditions of inductively coupled plasma mass spectrometry system(ICP-MS) were set up to determine the $^{99}Tc$ after the separation process. The minimum detectable activity(MDA) was 15 mBq/kg-dry in this analytical procedure. The $^{99}Tc$ concentration in soils of Jeju and Kori were measured in the rage of 33.73-89.16 mBq/kg-dry. Those values were less than those reported in other countries and seemed to be originated from atmospheric fallout.

  • PDF

Copper Isotope Measurements Using a Neptune MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 구리 동위원소 분석법)

  • Park, Sanghee;Ryu, Jong-Sik;Shin, Hyung Seon;Kil, Youngwoo;Jo, Yunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2016
  • Copper is an essential transition metal involving in various biogeochemical processes. With the recent advances in analytical techniques and mass spectrometry, such as MC-ICP-MS, it is possible to measure Cu isotopes, which allows us to understand various biogeochemical processes in detail. Nonetheless, few studies have been performed in South Korea. In this study, we compared two purification methods previously reported using an anion exchange resin ($AG^{(R)}$ MP-1M), developed the best method in our lab environment, and then verified it by measuring Cu isotopic compositions in two USGS geological reference materials (BHVO-2 and BIR-1a). Although all matrix cations causing mass bias were effectively removed through both two methods with the yield of better than 95%, the method using the mixture of HCl and $H_2O_2$ only displays Cu isotopic compositions, in excellent agreement with reported values within the error. The method developed in this study is expected to be commonly applied to earth and environmental sciences.

Trace Element Compositions and Optically Stimulated Luminescence Characteristics of Sedimentary Quartz (퇴적물 내 석영의 광여기 루미네선스 특성과 미량원소 조성)

  • Jeon, Gi-Young;Choi, Jeong-Heon;Kil, Young-Woo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.357-365
    • /
    • 2010
  • Optically stimulated luminescence (OSL) of quartz is commonly applied to the age dating of Quaternary sediments. However, one of the issues is that some of the quartz samples are not suitable to OSL dating. Mineralogical analysis of the quartz samples with diverse OSL signals are required to strengthen the reliability and applicability of the OSL dating. We analysed the OSL signal characteristics of sedimentary quartz samples from diverse geological environments and measured their trace element contents using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Quartz samples could be grouped into ones suitable to OSL dating and ones unsuitable on the basis of their OSL signal characteristics. The average trace element contents ranged from 73 to 260 ppm (Al), and from 61 to 248 ppm (Ti) with minor Li, Mg, Cr, Mn, and Fe contents below 40 ppm. We did not find any significant variation of trace element contents of quartz samples consistent with their OSL signal characteristics. This indicates unknown mineralogical factors causing diverse OSL characteristics which should be confirmed by further analysis of sufficient set of samples.