• Title/Summary/Keyword: spectrometry (ICP-MS)

Search Result 173, Processing Time 0.026 seconds

Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교)

  • Kang, Min-Kyung;Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

Comparison Study of Sensitivity Factors of Elements in Glow Discharge- & Inductively Coupled Plasma- Mass Spectrometry

  • Kim, Young-Sang;Plotnikov, M.;Hoffmann, Volker
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1991-1995
    • /
    • 2005
  • Sensitivity factors of elements by a glow discharge mass spectrometry (GD-MS) were intensively investigated and compared with a laser ablation inductively coupled plasma-mass spectrometry (ICP-MS). In case of copper matrix, the sensitivity factor by GD-MS generally decreases with the increase of the mass number of element. The details are a little different between each data measured by Faraday and multiplier detectors. The factor by a multiplier detector drastically decreases with the mass increase in the region of low mass as in Faraday detector’s case, but slowly in the high mass region. On the contrast, the sensitivity factor of solution standard by a conventional ICP-MS slowly increases with the increase of elemental mass number even though there are some exceptions such as gold and also the sensitivity factor by a laser ablation ICP MS generally increases with mass number of element in the specimen of glass type. In case of steel matrix, any definite trends could not be shown in the relationship between the GD-MS’s sensitivity factor and elemental mass.

Analysis of Copper, Zinc in Serum Using ICP-MS & AAS (ICP-MS와 AAS를 이용한 체내 혈청 Cu, Zn 분석에 관한 연구)

  • Lee, Yea-Jin;Kim, Dong-Yub;Lee, Go-Eun;Jo, Young-Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The exposure of human beings to toxic trace metals (Cu, Zn) continues to be an important public health issue and concern. This study was conducted to assess the exposure to trace metals (Cu, Zn) in the general Korean population by inductively coupled plasma mass spectrometry (ICP-MS) and Atomic absorption spectrometry (AAS). Serum samples were obtained from 40 healthy volunteers. Specimens were collected in special container and we applied sample processing to minimize contamination. We used ICP-MS and AAS to analyze simultaneously the concentration of metals including copper, zinc. Distribution of trace metal levels in the general healthy population showed lower values. The results in this study can provide background data for clinical studies associated with trace metal exposure in the korean population.

  • PDF

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.

Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead (골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교)

  • Yoon, Chungsik;Choi, Inja;Park, Sungkyun;Kim, Rokho
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • This study was conducted to evaluate two sample digestion procedures and instrumental determination parameters for analysis of lead in bone. Amputated human legs were treated by acid digestion or microwave dissolution prior to spectrometric analysis. Inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GF-AAS) were used for determining bone lead levels. Recovery efficiencies using standard reference material from acid digestion measured by ICP-MS were in good agreement with those of the certified value, but in cases of acid digestion by GF-AAS and microwave digestion by both two methods, recovery underestimated and overestimated, respectively. For the bone samples, the lead concentrations obtained by ICP-MS after acid digestionwere in good agreement with those by GF-AAS (correlation coefficient = 0.983), but GF-AAS gave systematically higher values than ICP-MS. While a good agreement between two analytical methods after microwave digestion was also obtained (correlation coefficient = 0.950), bone lead concentrations from microwave were relatively higher than those from acid digestion. In conclusion, the use of the simple nitric acid digestion procedure at an ambient temperature coupled to ICP-MS seems to be efficient for the determination of lead in bone in consideration for both the convenience and validity.

High sensitivity determination of iridium contents in ultra-basic rocks by INAA with coincidence gamma-ray detection

  • Ebihara, Mitsuru;Shirai, Naoki;Kuwayama, Jin;Toh, Yosuke
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.423-428
    • /
    • 2022
  • Very low contents (in the range of 10-9 g/g) of Ir in mantle-derived rock samples (komatiites) were non-destructively determined by INAA coupled with coincidence gamma-ray spectrometry using 16 Ge detectors. Aliquots of the same samples were analyzed by NiS fire-assay ICP-MS for Ir and other platinum group elements. Because the INAA procedure used in this study is non-destructive and is almost free from spectral interference in gamma-ray spectrometry, the INAA values of Ir contents obtained in this study can be highly reliable. Iridium values obtained by ICP-MS were consistent with the INAA values, implying that the ICP-MS values of Ir obtained in this study are equally reliable. Under the present experimental conditions, detection limits were estimated to be 1 pg/g, which corresponds to 0.1 pg for a sample mass of 0.1 g. These levels can be even lowered by an order of magnitude, if necessary, which cannot be achieved by ICP-MS carried out in this study.

Determination of Ni, Cr, Mo in Low Alloy Steel Reference Materials by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry (동위원소희석 유도결합플라스마질량분석법에 의한 저 합금강 표준시료중의 Ni, Cr, Mo의 분석)

  • Suh, Jungkee;Woo, Jinchoon;Min, Hyungsik;Yim, Myeongcheul
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.82-89
    • /
    • 2003
  • Isotope dilution mass spectrometry (IDMS) was applied to the determination of Ni, Cr, Mo in low alloy steel reference materials. The Mo isotope ratio measurement was performed by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP/MS) using ammonia as a reaction cell gas. In the case of Ni and Cr measurement, all data were obtained at medium resolution mode (m/${\Delta}m=3000$) of double focusing sector field high resolution inductively coupled plasma mass spectrometry (HR-ICP/MS). For the method validation of the technique was assessed using the certified reference materials such as NIST SRM 361, NIST SRM 362, NIST SRM 363, NIST SRM 364, NIST SRM 36b. This method was applied to the determination of Ni, Cr and Mo in low alloy steel sample (CCQM-P25) provided by NMIJ for international comparison study.

The chemical speciation and analysis of trace elements in sediment with neutron activation analytical method(NAA) and atomic mass spectrometry (중성자 방사화분석법과 원자질량분석법을 이용한 침전물 시료속에 존재하는 미량원소들의 화학종 분류 및 분석)

  • Nam, Sang-Ho;Kim, Jae-Jin;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.358-367
    • /
    • 2003
  • In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will play an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA.

Comparison of Human Blood Cadmium Concentrations using Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교)

  • Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kang, Min-Kyung;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.491-501
    • /
    • 2018
  • Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: $0.000{\mu}g/L$, MDL: $0.06{\mu}g/L$) was lower than that of GF-AAS (IDL: $0.085{\mu}g/L$, MDL: $0.327{\mu}g/L$). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ${\pm}30%$ of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

Determination of Rare Earth Elements Abundance in Alkaline Rocks by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) (ICP-MS를 이용한 알칼리암의 희토류원소 정량분석)

  • Hur, Soon-Do;Lee, Jong-Ik;Lee, Mi-Jung;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.25 no.1
    • /
    • pp.53-62
    • /
    • 2003
  • Inductively coupled plasma mass spectrometry (ICP-MS) is useful instrument for determining abundance of rare earth elements, due to very low detection limits and rapid data acquisition. In this article, two methods are used for decomposition of alkaline rocks; close vessel acid digestion and $Na_2Co_3$ fusion. The two analytical results show good agreements. Considering total dissolved solids and detection limits, the most adequate dilution factor is 5,000 times. Polyatomic ion interferences during analysis can give rise to Inaccuracies. After correction from oxide and hydroxide interference, the analytical result show 20-30% decrease for Gd and Tm, 10-20% decrease for Tb and Er. In comparing the analytical results from KORDI with other institutes, most rare earth elements abundance show good agreements except Lu.