• Title/Summary/Keyword: spectral band

Search Result 869, Processing Time 0.023 seconds

Color Filter Based on a Sub-Wavelength Patterned Poly-Silicon Grating Fabricated using Laser Interference Lithography (광파장 이하의 주기를 갖는 다결정 실리콘 격자 기반의 컬러필터)

  • Yoon, Yeo-Taek;Lee, Hong-Shik;Lee, Sang-Shin;Kim, Sang-Hoon;Park, Joo-Do;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.20-24
    • /
    • 2008
  • A color filter was proposed and demonstrated by incorporating a subwavelength patterned 1-dimensional grating in poly silicon. It was produced by employing the laser interference lithography method, providing much wider effective area compared to the conventional e-beam lithography. A $SiO_2$ layer was introduced on top of the silicon grating layer as a mask for the etching of the silicon, facilitating the etching of the silicon layer. It was theoretically found that the selectivity of the filter was also improved thanks to the oxide layer. The parameters for the designed device include the grating pitch of 450 nm, the grating height of 100 nm and the oxide-layer height of 200 nm. As for the fabricated filter, the spectral pass band corresponded to the blue color centered at 470 nm and the peak transmission was about 40%. Within the effective area of $3{\times}3mm^2$, the variation in the relative transmission efficiency and in the center wavelength was less than 10% and 2 nm respectively. Finally, the influence of the angle of the incident beam upon the transfer characteristics of the device was investigated in terms of the rate of the relative transmission efficiency, which was found to be equivalent to 1.5%/degree.

Analysis of Electrical and Optical Characteristics of Silicon Based High Sensitivity PIN Photodiode (Silicon기반 고감도 PIN Photodiode의 전기적 및 광학적 특성 분석)

  • Lee, Jun-Myung;Kang, Eun-Young;Park, Keon-Jun;Kim, Yong-Kab;Hoang, Geun-Chang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.6
    • /
    • pp.1407-1412
    • /
    • 2014
  • In order to improve spectrum sensitivity of photodiode for detection of the laser at 850 nm ~ 1000 nm of near-infrared wavelength band, this study has produced silicon-based fast film PIN photodiode and analyzed electrical and optical properties. The manufactured device is packaged in TO-18 type. The electrical properties of the dark currents both Anode 1 and Anode 2 have valued of approximately 0.055 nA for 5 V reverse bias, while the capacitance showed 19.5 pF at frequency range of 1 kHz and about 19.8 pF at the range of 200 kHz for 0 V. In addition, the rising time of output signal was verified to have fast response time of about 30 ns for 10 V. For the optical properties, the best spectrum sensitivity was 0.66 A/W for 880 nm, while it was relatively excellent value of 0.45 A/W for 1,000 nm.

Study of Optical Properties of InxGa1-xN/GaN Multi-Quantum-Well (InxGa1-xN/GaN 다중양자우물 구조의 광학적 성질 연구)

  • Kim, Ki-Hong;Kim, In-Su;Park, Hun-Bo;Bae, In-Ho;Yu, jae-In;Jang, Yoon-Seok
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2009
  • Temperature and injection current dependence of electroluminescence(EL) spectral intensity of the $In_xGa_{1-x}N$/GaN multi-quantum wells(MQW) have been studied over a wide temperature range and as a function of injection current level. It is found that a temperature-dependent variation pattern of the EL efficiency under very low and high injection currents shows a drastic difference. This unique EL efficiency variation pattern with temperature and current can be explained field effects due to the driving forward bias in presence of internal(piezo and spontaneous polarization) fields. Increase of the indium content in $In_xGa_{1-x}N$/GaN multiple quantum wells gives rise to a redshift of 80 meV and 22 meV for green and blue MQW, respectively. It can be explained by carrier localization by potential fluctuation of multiple quantum well and MQW structures also shows a keen difference owing to the different indium content in InGaN/GaN MQW.

Feasibility of near-infrared spectroscopic observation for traditional fermented soybean production (전통 메주 제조과정에 있어서 근적외 모니터링 가능성 조사)

  • Jeon, Jae Hwan;Lee, Seon Mi;Cho, Rae Kwang
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.145-152
    • /
    • 2017
  • In this study, near infrared (NIR) spectroscopy known as a non-destructive analysis technique was applied to investigate peptide cleavage and consequent release of amino acids in soybean lumps as affected by its moisture content and incubation time during fermentation at 25 for 3 weeks. The NIR spectra of the soybean lump semi-dried and soaked in saline water showed that absorption intensity around 1,400 nm originating from hydrogen bonds of water decreased and absorption band shifted to 1,430 nm as moisture content decreased during incubation at 25 for 3 weeks. In addition, absorption around 2,050 nm which was assigned to amino groups increased as incubation time increased. NIR spectra data from 1,000 to 2,250 nm showed higher accuracy in the discriminant analysis between outside and inside parts of fermented soybean lumps than visible spectra result. NIR spectroscopy for the amino acid and moisture contents in traditional fermented soybean lumps showed relatively good accuracy with the multiple correlation coefficient ($R^2$) of 0.91 and 0.81, respectively, and root mean square error of cross validation (RMSECv) of 0.23 and 0.83%, respectively, in partial least square regression (PLSR). These results indicate that NIR spectral observations could be applicable to control the fermentation process for preparation of soybean products.

MIRIS Science Missions

  • Jeong, Woong-Seob;Matsumoto, Toshio;Seon, Kwang-Il;Lee, Dae-Hee;Ree, Chang-Hee;Park, Young-Sik;Nam, Uk-Won;Pyo, Jeong-Hyun;Moon, Bong-Kon;Park, Sung-Joon;Cha, Sang-Mok;Park, Jang-Hyun;Lee, Duk-Hang;Lee, Sung-Ho;Yuk, In-Soo;Ahn, Kyung-Jin;Cho, Jung-Yeon;Lee, Hyung-Mok;Han, Won-Yong
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.26.4-27
    • /
    • 2010
  • The main payload of STSAT-3 (Science and Technology Satellite 3), MIRIS (Multipurpose InfraRed Imaging System) is the first Korean infrared space mission to explore the near-infrared sky with a small astronomical instrument, which is being developed by KASI. The 8-cm passively cooled telescope with a wide field of view (3.67 deg. $\times$ 3.67 deg.) will be operated in the wavelength range from 0.9 to $2{\mu}m$. It will carry out wide field imaging and the emission line survey. The main purposes of MIRIS are to perform the Cosmic Infrared Background (CIB) observation at two wide spectral bands (I and H band) and to survey the Galactic plane at $1.88{\mu}m$ wavelength, the Paschen-$\alpha$ emission line. CIB observation enables us to reveal the nature of degreescale CIB fluctuation detected by the IRTS (Infrared Telescope in Space) mission and to measure the absolute CIB level. The Pashen-$\alpha$ emission line survey of Galactic plane helps us to understand the origin of Warm Ionized Medium (WIM) and to find the physical properties of interstellar turbulence related to star formation. Here, we also discuss the observation plan with MIRIS.

  • PDF

Forest Damage Detection Using Daily Normal Vegetation Index Based on Time Series LANDSAT Images (시계열 위성영상 기반 평년 식생지수 추정을 통한 산림생태계 피해 탐지 기법)

  • Kim, Eun-sook;Lee, Bora;Lim, Jong-hwan
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_2
    • /
    • pp.1133-1148
    • /
    • 2019
  • Tree growth and vitality in forest shows seasonal changes. So, in order to detect forest damage accurately, we have to use satellite images before and after damages taken at the same season. However, temporal resolution of high or medium resolution images is very low,so it is not easy to acquire satellite images of the same seasons. Therefore, in this study, we estimated spectral information of the same DOY using time-series Landsat images and used the estimates as reference values to assess forest damages. The study site is Hwasun, Jeollanam-do, where forest damage occurred due to hail and drought in 2017. Time-series vegetation index (NDVI, EVI, NDMI) maps were produced using all Landsat 8 images taken in the past 3 years. Daily normal vegetation index maps were produced through cloud removal and data interpolation processes. We analyzed the difference of daily normal vegetation index value before damage event and vegetation index value after event at the same DOY, and applied the criteria of forest damage. Finally, forest damage map based on daily normal vegetation index was produced. Forest damage map based on Landsat images could detect better subtle changes of vegetation vitality than the existing map based on UAV images. In the extreme damage areas, forest damage map based on NDMI using the SWIR band showed similar results to the existing forest damage map. The daily normal vegetation index map can used to detect forest damage more rapidly and accurately.

Estimation of Simulated Radiances of the OSMI over the Oceans (대양에서의 OSMI 모의 복사량 산출)

  • 임효숙;김용승;이동한
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.3
    • /
    • pp.227-238
    • /
    • 1999
  • In advance of launch, simulated radiances of the Ocean Scanning Multispectral Imager (OSMI) will be very useful to guess the real imagery of OSMI and to prepare for data processing of OSMI. The data processing system for OSMI which is one of sensors aboard Korea Multi-Purpose Satellite (KOMPSAT) scheduled for launch in 1999 is developed based on the SeaWiFS Data Analysis System (SeaDAS). Simulation of radiances requires information on the spectral band, orbital and scanning characteristics of the OSMI and KOMPSAT spacecraft. This paper also describes a method to create simulated radiances of the OSMI over the oceans. Our method for constructing a simulated OSMI imagery is to propagate a KOMPSAT orbit over a field of Coastal Zone Color Scanner (CZCS) pigment concentrations and to use the values and atmospheric components for calculation of total radiances. A modified Brouwer-Lyddane model with drag was used for the realistic orbit prediction, the CZCS pigment concentrations were used to compute water-leaving radiances, and a variety of radiative transfer models were used to calculate atmospheric contributions to total radiances detected by OSMI. Imagery of the simulated OSMI radiances for 412, 443, 490, 555, 765, 865nm was obtained. As expected, water-leaving radiances were only a small fraction (below 10%) of total radiances and sun glint contaminations were observed near the solar declination. Therefore, atmospheric correction is critical in the calculation of pigment concentration from total radiances. Because the imagery near the sun's glitter pattern is virtually useless and must be discarded, more advanced data collection planning will be required to succeed in the mission of OSMI which is consistent monitoring of global oceans during three year mission lifetime.

The GOCI-II Early Mission Marine Fog Detection Products: Optical Characteristics and Verification (천리안 해양위성 2호(GOCI-II) 임무 초기 해무 탐지 산출: 해무의 광학적 특성 및 초기 검증)

  • Kim, Minsang;Park, Myung-Sook
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1317-1328
    • /
    • 2021
  • This study analyzes the early satellite mission marine fog detection results from Geostationary Ocean Color Imager-II (GOCI-II). We investigate optical characteristics of the GOCI-II spectral bands for marine fog between October 2020 and March 2021 during the overlapping mission period of Geostationary Ocean Color Imager (GOCI) and GOCI-II. For Rayleigh-corrected reflection (Rrc) at 412 nm band available for the input of the GOCI-II marine fog algorithm, the inter-comparison between GOCI and GOCI-II data showed a small Root Mean Square Error (RMSE) value (0.01) with a high correlation coefficient (0.988). Another input variable, Normalized Localization Standard (NLSD), also shows a reasonable correlation (0.798) between the GOCI and GOCI-II data with a small RMSE value (0.007). We also found distinctive optical characteristics between marine fog and clouds by the GOCI-II observations, showing the narrower distribution of all bands' Rrc values centered at high values for cloud compared to marine fog. The GOCI-II marine fog detection distribution for actual cases is similar to the GOCI but more detailed due to the improved spatial resolution from 500 m to 250 m. The validation with the automated synoptic observing system (ASOS) visibility data confirms the initial reliability of the GOCI-II marine fog detection. Also, it is expected to improve the performance of the GOCI-II marine fog detection algorithm by adding sufficient samples to verify stable performance, improving the post-processing process by replacing real-time available cloud input data and reducing false alarm by adding aerosol information.

Comparison of Pixel-based Change Detection Methods for Detecting Changes on Small Objects (소형객체 변화탐지를 위한 화소기반 변화탐지기법의 성능 비교분석)

  • Seo, Junghoon;Park, Wonkyu;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.177-198
    • /
    • 2021
  • Existing change detection researches have been focused on changes of land use and land cover (LULC), damaged areas, or large vegetated and water regions. On the other hands, increased temporal and spatial resolution of satellite images are strongly suggesting the feasibility of change detection of small objects such as vehicles and ships. In order to check the feasibility, this paper analyzes the performance of existing pixel-based change detection methods over small objects. We applied pixel differencing, PCA (principal component analysis) analysis, MAD (Multivariate Alteration Detection), and IR-MAD (Iteratively Reweighted-MAD) to Kompsat-3A and Google Map images taken within 10 days. We extracted ground references for changed and non-changed small objects from the images and used them for performance analysis of change detection results. Our analysis showed that MAD and IR-MAD, that are known to perform best over LULC and large areal changes, offered best performance over small object changes among the methods tested. It also showed that the spectral band with high reflectivity of the object of interest needs to be included for change analysis.

Acoustic Analysis and Auditory-Perceptual Assessment for Diagnosis of Functional Dysphonia (기능성 음성장애의 진단을 위한 음향학적, 청지각적 평가)

  • Kim, Geun-Hyo;Lee, Yeon-Yoo;Bae, In-Ho;Lee, Jae-Seok;Lee, Chang-Yoon;Park, Hee-June;Lee, Byung-Joo;Kwon, Soon-Bok
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.212-222
    • /
    • 2018
  • Background and Objectives : The purpose of this study was to compare the measured values of acoustic and auditory perceptual assessments between normal and functional dysphonia (FD) groups. Materials and Methods : 102 subjects with FD and 59 normal voice groups were participated in this study. Mid-vowel portion of the sustained vowel /a/ and two sentences of 'Sanchaek' were edited, concatenated, and analyzed by Praat script. And then auditory-perceptual (AP) rating was completed by three listeners. Results : The FD group showed higher acoustic voice quality index version 2.02 and version 3.01 (AVQIv2 and AVQIv3), slope, Hammarberg index (HAM), grade (G) and overall severity (OS), values than normal group. Additionally, smoothed cepstral peak prominence in Praat (PraatCPPS), tilt, low-to high spectral band energies (L/H ratio), long-term average spectrum (LTAS) in FD group were lower than normal voice group. And the correlation among measured values ranged from -0.250 to 0.960. In ROC curve analysis, cutoff values of AVQIv2, AVQIv3, PraatCPPS, slope, tilt, L/H ratio, HAM, and LTAS were 3.270, 2.013, 13.838, -22.286, -9.754, 369.043, 27.912, and 34.523, respectively, and the AUC of each analysis was over .890 in AVQIv2, AVQIv3, and PraatCPPS, over 0.731 in HAM, tilt, and slope, over 0.605 in LTAS and L/H ratio. Conclusions : In conclusion, AVQI and CPPS showed the highest predictive power for distinguishing between normal and FD groups. Acoustic analyses and AP rating as noninvasive examination can reinforce the screening capability of FD and help to establish efficient diagnosis and treatment process plan for FD.