• Title/Summary/Keyword: spectral amplitude

Search Result 275, Processing Time 0.024 seconds

SPECIAL CONSIDERATION ON THE RADARSAT REPEAT-PASS SAR INTERFEROMETRY

  • Kim, Sang-Wan;Won, Joong-Sun;Moon, Wooil-M.
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.474-478
    • /
    • 1999
  • SAR interferometry (InSAR) using the space-borne Synthetic Aperture Radar (SAR) have recently become one of the most effective tools monitoring surface changes caused by landslides, earthquakes, subsidences or volcanic eruption. This study focuses on examining the feasibility of InSAR using the RADARSAT data. Although the RABARSAT SAR with its high resolution and variable incidence angle has several advantages for repeat-pass InSAR, it has two key limitations: first, the orbit is not precisely known; and second, RADARSAT's 24-day repeat pass interval is not very favourable for retaining useful coherence. In this study, two pairs of RADARSAT data in the Nahanni area, NWT, Canada have been tested. We will discuss about the special consideration required on the interferometric processing steps specifically for RADARSAT data including image co-registration, spectral filtering in both azimuth and range, estimation of the interferometric baseline, and correction of the interferogram with respect to the "flat earth" phase contribution. Preliminary results can be summarized as: i) the properly designed azimuth filter based upon the antenna characteristic improves coherence considerably if difference in Doppler centroid of the two images is relatively large; ii) the co-registration process combined by fringe spectrum and amplitude cross-correlation techniques results in optimal matching; iii) the baseline is not always possible to be estimated from the definitive orbit information.

  • PDF

Numerical modeling of dynamic compaction process in dry sands considering critical distance from adjacent structures

  • Pourjenabia, Majid;Hamidi, Amir
    • Structural Engineering and Mechanics
    • /
    • v.56 no.1
    • /
    • pp.49-56
    • /
    • 2015
  • Dynamic compaction (DC) is a useful method for improvement of granular soils. The method is based on falling a tamper (weighting 5 to 40 ton) from the height of 15 to 30 meters on loose soil that results in stress distribution, vibration of soil particles and desirable compaction of the soil. Propagation of the waves during tamping affects adjacent structures and causes structural damage or loss of performance. Therefore, determination of the safe or critical distance from tamping point to prevent structural hazards is necessary. According to FHWA, the critical distance is defined as the limit of a particle velocity of 76 mm/s. In present study, the ABAQUS software was used for numerical modeling of DC process and determination of the safe distance based on particle velocity criterion. Different variables like alluvium depth, relative density, and impact energy were considered in finite element modeling. It was concluded that for alluvium depths less than 10 m, reflection of the body waves from lower boundaries back to the soil and resonance phenomenon increases the critical distance. However, the critical distance decreases for alluvium depths more than 10 m. Moreover, it was observed that relative density of the alluvium does not significantly influence the critical distance value.

Probabilistic sensitivity analysis of suspension bridges to near-fault ground motion

  • Cavdar, Ozlem
    • Steel and Composite Structures
    • /
    • v.15 no.1
    • /
    • pp.15-39
    • /
    • 2013
  • The sensitivities of a structural response due to variation of its design parameters are prerequisite in the majority of the algorithms used for fundamental problems in engineering as system uncertainties, identification and probabilistic assessments etc. The paper presents the concept of probabilistic sensitivity of suspension bridges with respect to near-fault ground motion. In near field earthquake ground motions, large amplitude spectral accelerations can occur at long periods where many suspension bridges have significant structural response modes. Two different types of suspension bridges, which are Bosporus and Humber bridges, are selected to investigate the near-fault ground motion effects on suspension bridges random response sensitivity analysis. The modulus of elasticity is selected as random design variable. Strong ground motion records of Kocaeli, Northridge and Erzincan earthquakes are selected for the analyses. The stochastic sensitivity displacements and internal forces are determined by using the stochastic sensitivity finite element method and Monte Carlo simulation method. The stochastic sensitivity displacements and responses obtained from the two different suspension bridges subjected to these near-fault strong-ground motions are compared with each other. It is seen from the results that near-fault ground motions have different impacts stochastic sensitivity responses of suspension bridges. The stochastic sensitivity information provides a deeper insight into the structural design and it can be used as a basis for decision-making.

Necessity and adequacy of near-source factors for seismically isolated buildings

  • Saifullah, Muhammad Khalid;Alhan, Cenk
    • Earthquakes and Structures
    • /
    • v.12 no.1
    • /
    • pp.91-108
    • /
    • 2017
  • Superstructures and isolation systems of seismically isolated buildings located close to active faults may observe increased seismic demands resulting from long-period and high-amplitude velocity and displacement pulses existent in near-fault ground motions as their fundamental periods may be close to or coincident with these near-fault pulse periods. In order to take these effects into account, the 1997 Uniform Building Code (UBC97) has specified near-source factors that scale up the design spectrum depending on the closest distance to the fault, the soil type at the site, and the properties of the seismic source. Although UBC97 has been superseded by the 2015 International Building Code in the U.S.A., UBC97 near-source factors are still frequently referred in the design of seismically isolated buildings around the world. Therefore it is deemed necessary and thus set as the aim of this study to assess the necessity and the adequacy of near-source factors for seismically isolated buildings. Benchmark buildings of different heights with isolation systems of different properties are used in comparing seismic responses obtained via time history analyses using a large number of historical earthquakes with those obtained from spectral analyses using the amplified spectrums established through UBC97 near-source factors. Results show that near-source factors are necessary but inadequate for superstructure responses and somewhat unconservative for base displacement response.

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • v.14 no.3
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

16-QAM-Based Highly Spectral-Efficient E-band Communication System with Bit Rate up to 10 Gbps

  • Kang, Min-Soo;Kim, Bong-Su;Kim, Kwang Seon;Byun, Woo-Jin;Park, Hyung Chul
    • ETRI Journal
    • /
    • v.34 no.5
    • /
    • pp.649-654
    • /
    • 2012
  • This paper presents a novel 16-quadrature-amplitude-modulation (QAM) E-band communication system. The system can deliver 10 Gbps through eight channels with a bandwidth of 5 GHz (71-76 GHz/81-86 GHz). Each channel occupies 390 MHz and delivers 1.25 Gbps using a 16-QAM. Thus, this system can achieve a bandwidth efficiency of 3.2 bit/s/Hz. To implement the system, a driver amplifier and an RF up-/down-conversion mixer are implemented using a $0.1{\mu}m$ gallium arsenide pseudomorphic high-electron-mobility transistor (GaAs pHEMT) process. A single-IF architecture is chosen for the RF receiver. In the digital modem, 24 square root raised cosine filters and four (255, 239) Reed-Solomon forward error correction codecs are used in parallel. The modem can compensate for a carrier-frequency offset of up to 50 ppm and a symbol rate offset of up to 1 ppm. Experiment results show that the system can achieve a bit error rate of $10^{-5}$ at a signal-to-noise ratio of about 21.5 dB.

Temporal and spatial fluctuation characteristics of sea surface temperature in Yeosu Bay, Korea (여수해만 수온의 시공간적 변동특성)

  • CHOO, Hyo-Sang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.56 no.4
    • /
    • pp.322-339
    • /
    • 2020
  • Temporal and spatial fluctuations of surface water temperature in Yeosu Bay for the period from 2010 to 2011 were studied using the data from temperature monitoring buoys deployed at 32 stations in the south coast of Korea. Temperatures in the northern part of the bay are higher in summer and lower in winter than in the southern part of the bay. The lowest and highest temperature of the annual mean are found at the eastern coast of POSCO and at the west of Dae Island, respectively. Cold water masses appear at estuarine area when the discharge of Sumjin river is affluent. Amplitude of temperature fluctuation whose period is less than semi-diurnal is largest at Hadong coast and around Dae Island. Spectral analysis of surface water temperature shows a significant peak at a periodic fluctuation of 0.5 to 24 days and about 15-day period of predominant fluctuation is most frequent in Yeosu Bay. From the cross-correlation analysis of temperature fluctuations, Yeosu Bay can be classified into six areas; the south area affected by South Sea of Korea, the mixed area in the center of the bay, the estuarine area affected by river discharge at the north of the bay, the hot waste water area near Hadong coast, the area around Dae Island and the area near Noryang Channel affected by the water in Jinju Bay, respectively.

Spectral Analysis and Performance Evaluation of VCXO using the Jig System (지그시스템을 이용한 VCXO의 스펙트럼 분석 및 성능평가)

  • Yoon Dal-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.4 s.310
    • /
    • pp.45-52
    • /
    • 2006
  • In his paper, we have developed the SMD(surface mounted device) type PECL(positive emitter-coupled logic) VCXO of the $5{\times}7mm$ size for gratifying the requested specifications and the multilayer ceramic SMD(surface mounted device) package technology. The VCXO wired with the PECL(positive emitter coupled logic) package take place a stray inductance and a parasitic capacitance by the length and the inner pattern of the VCXO and the amplitude attenuation and signal loss due to the reflection of power source and the noise component. We have developed the Zig system to analyze the precise spectrum and evaluate the performance. The basic operating voltage is the 3.3 V and have the frequency range of 120MHz-180MHz. The Q factor is over 5K and it has the low jitter characteristics of 3.5 ps and low phase noise.

An Analysis of Characteristics of Floor Dynamic Properties and Bang-machine Impact Force on Floating Floor Using System Analysis (시스템 해석을 이용한 뜬바닥구조에서의 바닥구조 동특성과 뱅머신의 충격력 특성 분석)

  • Mun, Dae-Ho;Park, Hong-Gun;Hwang, Jae-Seung;Hong, Geon-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.390-398
    • /
    • 2014
  • Heavy-weight floor impact noise is directly related to the impact source and floor vibration property. Dynamic properties of the standard floating floor that is used in Korea was investigated using accelerance, acceleration energy spectral density(ESD), and structural modal test. In the standard floating floor, natural frequency was decreased by the finishing mortar mass and the damping ratio was increased. Bang-machine force spectrum acting on the concrete slab can be calculated using inverse system analysis. Impact force acting on concrete slab is changed by interaction of finishing mortar and resilient material. The amplitude of the bang-machine force spectrum was amplified in low frequency range(below 100 Hz), and over 100 Hz was decreased. Changed force spectrum influence to the response of structure vibration, so the heavy-weight floor impact noise level was changed.

VDSL 가입자 전송기술 개발 및 표준화 동향

  • 강규민;임기홍
    • Information and Communications Magazine
    • /
    • v.16 no.10
    • /
    • pp.112-124
    • /
    • 1999
  • 본 논문에서는 FTTC/VDSL (Fiber-to-the-Curb/Very High-speed Digital Subscriber Line) 전송시스템의 개발동향과 ANSI, ETSI, ITU등의 표준화 위원회에서 현재 진행중인 VDSL 시스템의 표준화 작업에 대해 기술하였다. 특히, POTS (Plain Old Telephone Service), BA-ISDA(Basic Access Integrated Services Digital Network), HDSL(High-rate Digital Subscriber Line), SDSL (Single-pair HDSL), ADSL(Asymmetric Digital Subscriber Line) 등의 다양한 xDSL (Digital Subscriber Line) 서비스들에서 발생하는 NEXT (Near-end Crosstalk)/FEXT (Far-end Crosstalk)와 같은 crosstalk를 최소화하기 위해 제안된 VDSL시스템의 주파수 대역과 PSD (Power Spectral Density) mask에 관해 설명하고, 순방향(down-stream) 채널과 역방향(upstream) 채널의 데이터 전송률이 대칭적인 VDSL전송시스템과 비대칭적인 VDSL 전송시스템 간의 주파수대역의 호환성 문제, RFI(Radio Frequency Interference) ingress/egress 문제의 해결 방안에 관해 기술하였다. 또한, 현재 VDSL Coalition과 VDSL Alliance 간에 논의 중인 VDSL 전송시스템의 변복조 방식에 관한 표준화 작업과정 및 순방향과 역방향에 할당될 band 개수에 따른 시스템 성능의 장단점 등에 관해 살펴보았다. 끝으로 현재 국내에서 개발되고 있는 FTTC/VDSL 전송시스템의 전체구조를 요약하고, 네트워크에서 가입자쪽으로 순방향 데이터 전송에 사용된 51.84 Mb/s 19-CAP (Carrierless Amplitude/Phase Modulation) 전송시스템과 가입자 댁내에서 네트워크 방향으로 역방향 데이터 전송에 사용된 1.62 Mb/s QPSK (Quadrature Phase Shift Keying) burst-mode TDMA (Time Division Multiple Access) 전송시스템 등의 동작 원리 및 구조를 기술하였다.

  • PDF