• Title/Summary/Keyword: spatial quality decrease

Search Result 51, Processing Time 0.032 seconds

Pan-Sharpening Algorithm of High-Spatial Resolution Satellite Image by Using Spectral and Spatial Characteristics (영상의 분광 및 공간 특성을 이용한 고해상도 위성영상 융합 알고리즘)

  • Choi, Jae-Wan;Kim, Yong-Il
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.2
    • /
    • pp.79-86
    • /
    • 2010
  • Generally, image fusion is defined as generating re-organized image by merging two or more data using special algorithms. In remote sensing, image fusion technique is called as Pan-sharpening algorithm because it aims to improve the spatial resolution of original multispectral image by using panchromatic image of high-spatial resolution. The pan-sharpened image has been an important task due to various applications such as change detection, digital map creation and urban analysis. However, most approaches have tended to distort the spectral information of the original multispectral data or decrease the spatial quality compared with the panchromatic image. In order to solve these problems, a novel pan-sharpening algorithm is proposed by considering the spectral and spatial characteristics of multispectral image. The algorithm is applied to the KOMPSAT-2 and QuickBird satellite image and the results showed that our method can improve the spectral/spatial quality compared with the existing fusion algorithms.

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detector

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2567-2571
    • /
    • 2023
  • Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To evaluate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.

Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement (시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안)

  • Moon, Jae-Seung;Shin, Min-Yong;Ahn, Seong-Cheol;Yoo, Mun-Gon;Kim, Su-Geun
    • Quality Improvement in Health Care
    • /
    • v.20 no.1
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

Post-Processing for Reducing Corner Outliers (Corner outlier 제거를 위한 후처리 기법)

  • 홍윤표;전병우
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.11-14
    • /
    • 2003
  • In block-based lossy video compression, severe quantization causes discontinuities along block boundaries so that annoying blocking artifacts are visible in decoded video imases. These blocking artifacts significantly decrease the subjective image quality. In order to reduce the blocking artifacts in decoded images, many algorithms have been proposed However studies on so called, corner outliers, have been very limited. Corner outliers make image edges look disconnected from those of neighboring blocks at cross block boundary. In order to solve this problem, we propose a corner outlier detection and compensation algorithm as post-processing in spatial domain The experiment results show that the proposed method provides much improved subjective image quality.

  • PDF

Evaluation of Image Quality & Absorbed Dose using MCNPX Simulation in the Digital Radiography System (디지털방사선영상시스템에서 MCNPX 시뮬레이션을 이용한 영상 품질 및 선량평가)

  • An, Hyeon;Lee, Dongyeon;Ko, Sungjin;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.327-335
    • /
    • 2016
  • The study is enforce to study image quality evaluation of condition provide the IEC and combination of clinical conditions each quality of radiation that image quality to assess the conditions provided to IEC in the clinical environment to conduct image quality assessment of the digital radiography system in the detector have environmental limits. First, image quality evaluation was evaluated by measuring the MTF, NPS using four quality of radiation and Using MCNPX simulation lastly DQE make a image quality evaluation after calculating the particle fluence to analyze spectrum quality of radiation. Second, Using MCNPX simulation of four quality of radiation was evaluated absorbed dose rate about electronic 1 per unit air, water, muscle, bone by using Radiation flux density and energy, mass-energy absorption coefficient of matter. Results of evaluation of image quality, MTF of four quality of radiation was satisfied diagnosis frequency domain 1.0 ~ 3.0 lp/mm of general X-ray that indicated 1.13 ~ 2.91 lp/mm spatial frequency. The NPS has added filter, spatial frequency 0.5 lp/mm at standard NPS showed a tendency to decrease after increase. Unused added filter, spatial frequency 0.5 lp/mm at standard NPS showed a certain NPS result value after decrease. DQE in 70 kVp / unuesd added filter(21 mm Al) / SID 150 cm that patial frequency 1.5 lp/mm at standard showed a tendency to decrease after certain value showed. Patial frequency in the rest quality of radiation was showed a tendency to decrease after increase. Results of evaluation of absorbed dose, air < water < muscle < bone in the order showed a tendency to increase. Based on the results of this study provide to basic data that present for the image quality evaluation method of a digital radiation imaging system in various the clinical condition.

Real-time fractal coding implementation using the PC (PC를 이용한 실시간 프랙탈 부호화 구현)

  • 김재철;박종식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.11
    • /
    • pp.2789-2800
    • /
    • 1996
  • Real time fractal coding for successive QCIF 144*176 luminance images has been implemented on a 50MHz IBM 486 personal computer. To satisfy the frame encoding speed and data compression ratio, following algorithms are adopted. In order to minimize encoding time, extension SAS being not searching of domain blocks is used. for reducing the bits per pixel, conventioal 4*4 range block is extended to 8*8 range block. and range block extension decrease quality of decoded image. For improvement quality of decoded image, the paper apply quad-tree partition mothod. In order to divide **8 range block, self-simiarity is compared 8*8 range block with spatial contractive transformed 8*8 domain block. According to self-simiarity, the block is partitioned and owing to block partition, increased encoding time is minimized. According to self-simiarity of 8*8 range block and spatial contractive transformed 8*8 domain block, number of fractal factor is varied. Simultaneously with minimizing the decrement of decoded image's quality, transmittion rate and encoding time is shorted. The results enable us to process the real-time fractal coding. For the claire test image, the average PSNR was 32.4dB, 0.12 bit rates and 33ms coding time per frame.

  • PDF

Evaluation of Image Quality for Radiographic Positioning using IEC Radiation Quality in the Digital Radiography System (디지털방사선시스템에서 IEC표준을 이용한 방사선 영상 품질의 평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.289-299
    • /
    • 2015
  • The purpose of this study is to evaluate and compare the quality of digital X-ray imaging system. The image quality evaluation was conducted By using Modulation transfer function indicating the quantitative resolution of the image and the noise power spectrum showing the noise characteristics. Using a IEC61267 radiation quality was applied to the geometry to be used in clinical and geometry presented in IEC62220-1 and Additional filter, grid, the clinical dose and the MTF value of edge phantom was measured. Result of the MTF corresponding to each item(Grid, Filter, SID, kVp, mAs), the clinical condition 100cm, 180cm, measurements of the spatial frequency of the MTF IEC62220-1Geometry 150cm became similarly apparent, rather spatial frequency was also the case high in clinical conditions 100cm. NPS results, as the dose(mAs) is increased, NPS showed that reduced. The image quality evaluation using IEC61267 the Radiation quality, Image quality of the video using the clinical conditions Geometry than image quality evaluation using IEC62220-1Geometry was better. It shows that MTF and NPC in IEC and clinical condition were not significantly different. In order to apply the evaluation method of image quality applied with clinical conditions rather than the future method, to be presented evaluation of IEC standard, based on the results of the image characterization studies in this paper, the methods that shows good quality of spatial resolution and decrease NPS value as the least dose, used suitable parameters for whether or not using added filter, grid, change SID and clinical quality(kVp), dose(mAs) etc should be found. then It is believed to be able to properly maintain the actual quality of the image of the digital radiographic imaging system in clinical.

Water Quality Variations in Jinhae Bay by Dredging & Operating the Sewage Disposal Plant (마산만 준설사업 및 하수처리장 가동에 따른 진해만의 수질변동)

  • YOON SUK-JIN;LEE IN-CHEOL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.117-122
    • /
    • 2004
  • This study investigates the spatial and temporal distribution characteristics and relationships among water quality parameters, which based on 6 years' data(from 1989 to 1994) measured at 16 stations on Jinhae Bay. The results of these analysis, monthly variations range between surface and bottom layer of water quality had a tendency to increase and decrease, and appeared to be at the maximum value in August. The relationships between concentration of COD ana nutrients(DIN and DIP), which obtained by correlation analysis of water quality, were shown $85\%$ and $74\%$, respectively. Using the cluster analysis to develop the division of the sea basin by the dendrogram, before and after dredging of Masan bay and operating a sewage disposal plant, the variation characteristics of water quality of Jinhae Bay were discussed. Through it, we can see the serious pollution of northen sea basin of Jinhae Bay(B2) although dredging Masan bay and operating the sewage disposal plant. As the results, it doesn't appear the improvement effect of water quality in spite of carrying out the effort of water quality improvement.

  • PDF

Quality Check Monitoring System for Advancing the Yield Rate based on Sensor (베어링 생산수율 향상을 위한 센서기반 품질 체크 모니터링 장치)

  • Xiang, Zhao;Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.22-28
    • /
    • 2019
  • This paper presents the monitoring method of machining error and quality check to improve the productivity of boring manufacturing process. Machining error usually appears as the offset of spatial location of actual cutting path compared to ideal cutting path. In order to monitor an error of workpiece, multiple factors affecting quality of boring, such as distortion of workpiece, clamping error, radial rotation error of the spindle and motion error of machine tools, were took into account. To verify the productive quality, we propose the quality check system. The system based on IT convergence analyzes the process error rate and saves the analyzed data in memory. Also, these play important roles in detecting an inferior production goods and can decrease the production cost and loss of bearing.

Spatial distribution of wastewater treatment plants in diverse river basins over the contiguous United States

  • Soohyun Yang;Olaf Buettner;Yuqi Liu;Dietrich Borchardt
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.142-142
    • /
    • 2023
  • Humans inevitably and continuously produce wastewater in daily life worldwide. To decrease the degradation of river water bodies and aquatic ecosystem therein, humans have built systems at different scales to collect, drain, and treat household-produced wastewater. Particularly, municipal wastewater treatment plants (WWTPs) with centralized controls have played a key role in reducing loads of nutrients in domestic wastewater for the last few decades. Notwithstanding such contributions, impaired rivers regarding water quality and habitat integrity still exist at the whole river basin scale. It is highly attributable to the absence of dilution capacity of receiving streams and/or the accumulation of the pollutant loads along flow paths. To improve the perspective for individual WWTPs assessment, the first crucial step is to achieve systematic understanding on spatial distribution characteristics of all WWTPs together in a given river basin. By taking the initiative, our former study showed spatial hierarchical distributions of WWTPs in three large urbanized river basins in Germany. In this study, we uncover how municipal WWTPs in the contiguous United States are distributed along river networks in a give river basin. The extended spatial scope allows to deal with wide ranges in geomorphological attributes, hydro-climatic conditions, and socio-economic status. Furthermore, we identify the relation of the findings with multiple factors related to human activities, such as the spatial distribution of human settlements, the degree of economy development, and the fraction of communities served by WWTPs. Generalizable patterns found in this study are expected to contribute to establishing viable management plans for recent water-environmental challenges caused by WWTP-discharges to river water bodies.

  • PDF