• 제목/요약/키워드: sources of ignition

검색결과 85건 처리시간 0.026초

전문가시스템 기법을 이용한 화재 원인진단 (Diagnosis of Fire-Causes by using Expert System technique)

  • 정국삼;김두현;김상철
    • 한국안전학회지
    • /
    • 제7권1호
    • /
    • pp.31-38
    • /
    • 1992
  • This paper presents a study on application of expert system technique for the diagnosis of fire-causes in plants. A need is recognized for new methods to diagnose exactly the causes of fires without the help of the human experts. To cope with the difficulty, the expert system techiuque is applied to this area. The expert system suggested in this paper is developed to infer the causes of fires(or, ignition source ) by using the information drawn from the circumstances in fire. For the convenience of inference, ignition sources we classified into eight types ; elecoic spark, adiabatic compression, welding spark, material of high temperature, impact and friction, spontaneous ignition, naked fire, and static electricity. The knowledge base is composed of the rule base and dynamic database, which contain the rules and facts obtained by the expenence in this area, respectively. Both depth-first search and backward chaining schemes are used in reasoning process. This expert system is written in an artificial intelligence language "PROLOG", and its availability is demonstrated through the case study.

  • PDF

점화 조건에 따른 수소 예혼합기에서의 화염 전파 (Flame Propagation within Hydrogen Premixed Gas mixture According to Ignition Condition)

  • 한조영;김정수;이균호;김병교
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.350-355
    • /
    • 2003
  • Flame onset and propagation within hydrogen premixed gas mixture are numerically investigated in an rectangular enclosure. A detailed chemistry for hydrogen reaction is applied to anticipate the thermochemical behavior of intermediate species appropriately. To facilitate computation, 10 species and 16 elementary reaction steps for hydrogen combustion are taken into account. On the basis of 30 % of hydrogen concentration in hydrogen-air mixture, the effects of position and quantity of ignition sources on the flame evolution are analyzed. From the simulation results, the means that can lessen the possible hazard caused by flame propagation are suggested.

  • PDF

노말프로판올과 아세틱에씨드 계의 최소자연발화온도(AIT) 측정 및 예측 (Measurement and Prediction of Autoignition Temperature(AIT) of n-Propanol and Acetic acid System)

  • 하동명
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.66-71
    • /
    • 2017
  • The autoignition temperature (AIT) is crucial combustible characteristics which need attention in chemical process that handle hazardous materials. The AIT, also to as minimum spontaneous ignition temperature(MSIT), is the lowest temperature of a hot surface at which the substance will spontaneously ignite without any obvious sources of ignition such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for process safety. This study measured the AITs of n-propanol+acetic acid system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-propanol and acetic acid which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-propanol+acetic acid system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation). In the case of n-propanol and acetic acid system, the minimum autoignition temperature behavior (MAITB), which is lower than the lower AIT, is shown among the two pure substances constituting the mixture.

4M 기법을 활용한 전기화재 예방대책 수립 연구 (A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

담뱃불 발화특성에 관한 실험적 연구 (A Experimental Study on Characteristics of the Ignition by Cigarette Light)

  • 윤인수;김병선;조원철;이태식
    • 한국재난관리표준학회지
    • /
    • 제1권1호
    • /
    • pp.81-87
    • /
    • 2008
  • 매년 감소하고 있는 금연 인구추세에도 불구하고 담뱃불은 전체 화재원인의 10% 이상을 차지하고 있다. 본 연구의 목적은 담뱃불에 의한 발화특성을 실험을 통하여 분석하는 것이다. 이를 위해 본 연구에서는 2006년 인천에서 담뱃불로 인해 발생된 것으로 추정되는 화재사건에 대한 사례를 분석하였으며, 대표적인 착화물의 사례로서 골판지, 가솔린, 래커 시너, 방수천, PVC 연질시트 및 폴리에틸렌에 대해 발화 실험을 실시였다. 실험결과 골판지의 경우 담뱃불로 인하여 발화되었으나 가솔린, 래커 시너, 방수천, PVC 연질시트 및 폴리에틸렌의 경우 담뱃불로 인해 발화되지 못 하였다. 대부분의 화재원인 조사자들이 가솔린이나 천막재가 담뱃불로 인해 발화되었을 거라고 주장해 온 것에 반해 본 연구에서는 이러한 주장이 타당성이 없을 수 있다는 것을 실험적으로 입증하였다.

  • PDF

누출특성을 통한 폭발위험장소 선정방법의 개선에 대한 연구 (A Study on the Improvement of Classification of Explosion Hazardous Area using Hypothetic Volume through Release Characteristic)

  • 김대연;천영우;이익모;황용우
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.31-39
    • /
    • 2017
  • Classify of explosion hazardous areas must be made at the site where flammable materials are used. This reason is that it is necessary to manage ignition sources in of explosion hazardous areas in order to reduce the risk of explosion. If such an explosion hazard area is widened, it becomes difficult to increase the number of ignition sources to be managed. The method using the virtual volume currently used is much wider than the result using CFD(Computational Fluid Dynamics). Therefore, we tried to improve the current method to compare with the new method using leakage characteristics. The result is a realistic explosion hazard if the light gas is calibrated to the mass and the heavy gas is calibrated to the lower explosion limit. However, it is considered that the safety factors should be taken into account in the calculated correction formula because such a problem should be considered as a buffer for safety.

열분석 실험에 의한 화약류 폐기물의 화재원인분석에 관한 연구 (Study on the Fire Cause Analysis for Explosives Waste by Thermal Analysis Experiment)

  • Koh, Jae-Sun
    • 한국재난정보학회 논문집
    • /
    • 제14권1호
    • /
    • pp.89-100
    • /
    • 2018
  • 지정(특수)폐기물로 처리되어야 할 폭발성 폐기물이 일반폐기물 처리장에 잘못 반입되어 폐기물 처리과정에서 폭발사고로 이어졌을 때 많은 인명과 재산피해가 수반되므로 향후 폐기물 배출업체는 처리에 적합 가능한 처리시설로 폐기물을 처리하여야 한다. 본론에서 언급한 바와 같이 화약류 포장재 폐기물(고체부타디엔)의 착화재연실험에서 모두 발화위험성이 확인되었고, 작은 점화원에도 쉽게 착화되어 급속하고 폭발적으로 연소되는 형태를 나타냄을 알 수 있었다. 특히 폐기물처리장에서의 화약류 포장재에 의한 화재 폭발사고 사례와 같이 화약류 포장재 폐기물이 소각폐기물처리장에 대량으로 반입되어 유기화합물 폐기물과 혼재되어 있을 때는 상호 산화반응과 열분해 등으로 가연성, 산화성 가스가 발생되어 스파크 등 점화원에 의해 착화되며 순간적으로 폭발로 이어지는 개연성이 있음을 확인 할 수 있었다. 본연구가 화재현장에서의 현장 감식에 있어서 작은 참고자료가 되었으면 하는 바람과 과학적인 발화원인 판정으로 소방기관이 화재조사 전문기관으로서 대외적인 공신력을 인정받고 신뢰성 향상에 기여하는 계기가 되기를 기대한다.

점화 신호 종류에 따른 PDE 점화회로의 작동 안정성 연구 (Reviewing of Operating Stability about Pulse Detonation Engine's Ignition Circuit to the Type of Power Sources)

  • 김정민;한형석;오세종;최정열
    • 한국추진공학회지
    • /
    • 제22권6호
    • /
    • pp.11-18
    • /
    • 2018
  • 펄스 데토네이션 엔진 (PDE는) 추진기관으로서 의미 있는 추력을 얻기 위해 100 Hz 이상의 높은 작동 주파수를 요구한다. 따라서 PDE는 높은 작동 주파수에서 정확하게 작동하는 점화 회로 필요로 한다. 이번 논문에서는 교류와 직류 전원을 이용하는 두 종류의 점화 회로를 설계하여 비교하였다. 두 회로는 16.66 에서 100.00 Hz 작동 주파수에서 입력 신호와 변압기의 1 차 코일에 인가되는 전압 변화를 측정하여 시험하였다. 실험 결과 직류 전원의 회로의 경우 증가된 작동 주파수에서 최대 5.15%의 작동 주파수 오차를 보였으나 교류 전원의 회로의 경우 33.33 Hz 이상부터는 거의 맞지 않는 결과를 보였다. 이를 통해 고주파 작동의 PDE에서는 직류 전원의 점화 회로가 선호됨을 확인하였다.

내압방폭을 위한 Safe Gap의 측정에 관한 연구 (A Study on the Safe Gap for Explosion-proof)

  • 오규형
    • 한국가스학회지
    • /
    • 제1권1호
    • /
    • pp.1-6
    • /
    • 1997
  • 가연성 가스가 존재하는 위험 분위기에서 전기기기를 사용할 경우 전기 스파크에 의한 폭발위험성이 존재하기 때문에 점화원을 격리시키거나 고립시키는 것이 필요하지만 현실적으로 점화원의 고립이 불가능하므로 폭발을 방지하기 위한 일반적인 방법으로 내압 방폭형전기기기를 사용하고 있다. 따라서 내압방폭기기의 내부에 침투한 가연성 가스가 폭발하여도 화염이나 열이 틈새를 통과하여 외부의 가연성 분위기를 점화시킬 수 없는 최대 틈새크기를 찾아야 할 필요가 있다. 본 논문에서는 수소-공기 혼합기와 메탄-공기 혼합기에 대하여 실험적 최대틈새크기(MESG)를 찾아내어 기존의 결과와 비교하고, MESG에 영향을 미치는 요인들을 찾아내고자 하였다. 실험장치는 내용적 8${\iota}$의 구형용기를 사용하였으며 실험 변수들로는 전화위치, 혼합기의 농도, 초기압력 등이었다. 실험결과 각각의 변수들에 의해 영향을 받으며 특히 농도와 초기압력에 크게 영향을 받는 것을 알 수 있었으며, 당량 농도 가까이에서 최소값을 나타내었으며 초기압력의 상승과 함께 MESG는 감소하였다.

  • PDF

ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구 (A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case)

  • 이정일
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.383-391
    • /
    • 2020
  • 연구목적 : 에너지 저장실의 외부 화염에 의한 내부자기 점화 및 점화를 식별하고, 과열로 인한 점화와 외부 열원에 의한 점화의 차이를 분석하는 것이다. 연구방법 : 분리막 녹는점 측정, 배터리 외부 수열 실험, 배터리 과충전 실험, 과충전과 외부수열에 의한 연소 시 전극 판 비교분석, 과충전 연소 특징, 외부수열 화재 연소특징, 3.4(전극판 비교)/ 3.5(과충전)/ 3.6(외부수열) 분석 실험을 하였다. 연구결과: 화재 발생 시까지 센서의 위치에 따른 온도 차이가 극심했음으로 기존처럼 한 모듈 당 온도 센서 두 개로는 측정값이 부족해 온도제어를 통한 화재를 사전에 방지할 수 없다고 판단한다. 결론: 단락이 점화원으로 작용하여 혼합가스에 착화돼 가스폭발이 발생하고, 폭발 압력에 의해 전극이 잘게 파손되며, 가루형태의 리튬산화물이 불꽃반응에 의해 폭죽과 유사한 불꽃이 분출되었다.