• Title/Summary/Keyword: source static

Search Result 417, Processing Time 0.027 seconds

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

Reducing the Harmonics of Static Var Compensator Using Multi-Step Inverter (멀티-스텝 인버터를 이용한 무효전력 보상장치의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.19-22
    • /
    • 2001
  • For stabilization and improving power factor in the power lines, various Static Var Compensators(SVC) have been considered to be installed and partly applicated already. With all these merits of the SVC, it stil has demerits, principally evoking harmonic problems. So far, many harmonic reduction type inverters have been used in various parts. In this paper, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control. The theoretical analysis on this system was confirmed through the computer simulation and the experiments.

  • PDF

Characteristics of Double Polarity Source-Grounded Gate-Extended Drain NMOS Device for Electro-Static Discharge Protection of High Voltage Operating Microchip (마이크로 칩의 정전기 방지를 위한 DPS-GG-EDNMOS 소자의 특성)

  • Seo, Yong-Jin;Kim, Kil-Ho;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.97-98
    • /
    • 2006
  • High current behaviors of the grounded gate extended drain N-type metal-oxide-semiconductor field effects transistor (GG_EDNMOS) electro-static discharge (ESD) protection devices are analyzed. Simulation based contour analyses reveal that combination of BJT operation and deep electron channeling induced by high electron injection gives rise to the 2-nd on-state. Thus, the deep electron channel formation needs to be prevented in order to realize stable and robust ESD protection performance. Based on our analyses, general methodology to avoid the double snapback and to realize stable ESD protection is to be discussed.

  • PDF

Static Analysis Tools Against Cross-site Scripting Vulnerabilities in Web Applications : An Analysis

  • Talib, Nurul Atiqah Abu;Doh, Kyung-Goo
    • Journal of Software Assessment and Valuation
    • /
    • v.17 no.2
    • /
    • pp.125-142
    • /
    • 2021
  • Reports of rampant cross-site scripting (XSS) vulnerabilities raise growing concerns on the effectiveness of current Static Analysis Security Testing (SAST) tools as an internet security device. Attentive to these concerns, this study aims to examine seven open-source SAST tools in order to account for their capabilities in detecting XSS vulnerabilities in PHP applications and to determine their performance in terms of effectiveness and analysis runtime. The representative tools - categorized as either text-based or graph-based analysis tools - were all test-run using real-world PHP applications with known XSS vulnerabilities. The collected vulnerability detection reports of each tool were analyzed with the aid of PhpStorm's data flow analyzer. It is observed that the detection rates of the tools calculated from the total vulnerabilities in the applications can be as high as 0.968 and as low as 0.006. Furthermore, the tools took an average of less than a minute to complete an analysis. Notably, their runtime is independent of their analysis type.

Analysis on Software Static Testing Results of Railway Signaling System (열차제어시스템 소프트웨어 정적 테스팅 적용시험 결과 분석)

  • Hwang, Jong-Gyu;Jo, Hyun-Jeong;Jeong, Rak-Gyo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Many function of railway signalling system which is in charge of most core function in a railway system are being operated by the software according to the development of computer technology. Accordingly, the source code testing to verify the safety of the railway signalling system software becomes to be more important, and related international standards highly recommend verifications on the source code also. For this reason, several related studies on vital source code verification were executed from several years ago in Korea. This paper performed tests through the application to railway signalling system being applied to the existing actual domestic railway sites through automated testing tools for coding rules of signalling system software and another signaling system software under development in Korea recently, and analyzed their results.

Control of Static Var Compensator Using A Cascade Typed Multilevel Voltage Source Inverter (멀티레벨 직렬 전압형 인버터를 이용한 무효전력보상기(SVC)의 제어)

  • Min, Wan-Ki;Park, Yong-Bae;Kim, Yeong-Han;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.332-335
    • /
    • 1996
  • Multilevel voltage source inverters are emerging as a new breed of power inverter options for high power applications. This paper presents a cascade typed multilevel voltage source inverter which has separate de sources for high voltage. This inverter is proposed for flexible ac transmission systems (FACTS) including static var compensator(SVC), series compensation and phase shifting. It can solve the problems of conventional transformer-based multipulse inverters and the problems of multilevel diode-clamped inverters. To show the superiority of multilevel cascaded inverter, simulation results are discussed in detail.

  • PDF

Validation Test Codes Development of Static Analysis Tool for Secure Software (안전한 소프트웨어 개발을 위한 정적분석 도구 시험코드 개발)

  • Bang, Jiho;Ha, Rhan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.5
    • /
    • pp.420-427
    • /
    • 2013
  • Recently, for secure software development, static analysis tools have been used mostly to analyze the source code of the software and identify software weaknesses caused of vulnerabilities. In order to select the optimal static analysis tool, both weaknesses rules and analysis capabilities of the tool are important factors. Therefore, in this paper we propose the test codes developed for evaluating the rules and analysis capabilities of the tools. The test codes to involve 43 weaknesses such as SQL injection etc. can be used to evaluate the adequacy of the rules and analysis capabilities of the tools.

Eringen's nonlocal theory for non-linear bending analysis of BGF Timoshenko nanobeams

  • Azandariani, Mojtaba Gorji;Gholami, Mohammad;Nikzad, Akbar
    • Advances in nano research
    • /
    • v.12 no.1
    • /
    • pp.37-47
    • /
    • 2022
  • In this paper, the non-linear static analysis of Timoshenko nanobeams consisting of bi-directional functionally graded material (BFGM) with immovable ends is investigated. The scratching in the FG nanobeam mid-plane, is the source of nonlinearity of the bending problems. The nonlocal theory is used to investigate the non-linear static deflection of nanobeam. In order to simplify the formulation, the problem formulas is derived according to the physical middle surface. The Hamilton principle is employed to determine governing partial differential equations as well as boundary conditions. Moreover, the differential quadrature method (DQM) and direct iterative method are applied to solve governing equations. Present results for non-linear static deflection were compared with previously published results in order to validate the present formulation. The impacts of the nonlocal factors, beam length and material property gradient on the non-linear static deflection of BFG nanobeams are investigated. It is observed that these parameters are vital in the value of the non-linear static deflection of the BFG nanobeam.

A Comparative Study on Interrelation between FDTD Source Models for Coaxial-Probe Feeding Structures (동축 프로브 급전구조에 대한 FDTD 전원 모델들의 상호 관계에 관한 비교 연구)

  • Hyun, Seung-Yeup
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.114-122
    • /
    • 2014
  • For an efficient finite-difference time-domain(FDTD) analysis of coaxial-probe feeding structures in radio frequency(RF) and microwave bands, an interrelation between equivalent source modeling techniques is investigated. In existing literature, equivalent source models with delta-gap or magnetic-frill concepts have been developed by many researchers. It is well known that FDTD implementation and computational accuracy of these source models are slightly different. In this paper, the interrelation between FDTD equivalent source models for coaxial feeding structures under the quasi-static approximation(QSA) is presented. As a function of FDTD equivalent source models, time-domain and frequency-domain responses of a coaxial-probe fed conical monopole antenna are calculated numerically. And comparison results of computational accuracy and efficiency are provided.

Enhanced (R)-2-(4-Hydroxyphenoxy)Propionic Acid Production by Beauveria bassiana: Optimization of Culture Medium and H2O2 Supplement under Static Cultivation

  • Hu, Hai-Feng;Zhou, Hai-Yan;Wang, Xian-Lin;Wang, Yuan-Shan;Xue, Ya-Ping;Zheng, Yu-Guo
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.8
    • /
    • pp.1252-1260
    • /
    • 2020
  • (R)-2-(4-hydroxyphenoxy)propionic acid (HPOPA) is a key intermediate for the preparation of aryloxyphenoxypropionic acid herbicides (R-isomer). In order to improve the HPOPA production from the substrate (R)-2-phenoxypropionic acid (POPA) with Beauveria bassiana CCN-A7, static cultivation and H2O2 addition were attempted and found to be conducive to the task at hand. This is the first report on HPOPA production under static cultivation and reactive oxygen species (ROS) induction. On this premise, the cultivation conditions and fermentation medium compositions were optimized. As a result, the optimal carbon source, organic nitrogen source, and inorganic nitrogen source were determined to be glucose, peptone, and ammonium sulfate, respectively. The optimal inoculum size and fermentation temperature were 13.3% and 28℃, respectively. The significant factors including glucose, peptone, and H2O2, identified based on Plackett-Burman design, were further optimized through Central Composite Design (CCD). The optimal concentrations were as follows: glucose 38.81 g/l, peptone 7.28 g/l, and H2O2 1.08 g/l/100 ml. Under the optimized conditions, HPOPA titer was improved from 9.60 g/l to 19.53 g/l, representing an increase of 2.03-fold. The results obtained in this work will provide novel strategies for improving the biosynthesis of hydroxy aromatics.