• 제목/요약/키워드: source location technique

검색결과 130건 처리시간 0.029초

음향방출기법을 이용한 열교환기 누설 검출 시스템 개발 (Development of Leak Detection System of Heat Exchanger using Acoustic Emission Technique)

  • 이민래;이준현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.65-71
    • /
    • 2001
  • In this paper, acoustic omission technique(AE) has been applied to detect leak for heat exchanger by analyzing the characteristics of signal obtained from leak. It was confirmed that the characteristics of the signal generated by the turbulence of gas in the heat exchanger is narrow band signal having between 130-250KHz. Generally, the amplitude of leak signal is increased as the leak size increasing, but showed no significant change at frequency characteristic. Leak source location can be found by searching for the point of highest signal amplitude by comparing wi th several fired sensors.

  • PDF

Development of gamma ray scanning coupled with computed tomographic technique to inspect a broken pipe structure inside laboratory scale vessel

  • Saengchantr, Dhanaj;Srisatit, Somyot;Chankow, Nares
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.800-806
    • /
    • 2019
  • This paper presents a laboratory experiment on data acquisition technique that applied to the gamma radiation scanning coupled with computed tomography (CT) technique for inspection of broken nozzle inside the vertical vessel. The acquisition technique was developed to inspect a large diameter vessel when suspicious problem location is not easily accessed. This technique allows the installation of gamma radiation source (Cesium 137, Cs-137), and detectors (Sodium Iodine. NaI(Tl)) from the accessible location to the required location and performs the scanning by designed pattern. To demonstrate the designed technique, top opened tank which installed with six cut steel pipes diameter of 76.2 mm (3") at a certain position was selected. They were assumed to be a gas riser pipes inside the vessel. Three studied cases were performed, (a) projection of well installed six pipes, (b) projection of one out of six broken pipe and (c) one of nozzle was assumed to be failure and fell down until one out of six pipes was broken and obstructed by nozzle. Results clearly indicated the capability of developed technique to distinguish between normal situation case and abnormal situation cases.

평면공간에서 다중 센서간 도달 시간차를 이용한 해석적인 최소제곱오차 음원 위치 추정 방법 (Closed-form Nonlinear Least-Squares Source Localization from Time-Difference of Arrival Measurements in Planar Space)

  • 신동훈
    • 한국군사과학기술학회지
    • /
    • 제14권4호
    • /
    • pp.694-699
    • /
    • 2011
  • A closed-form technique is presented for estimating a single source location from a set of noisy time delay measurements between distributed sensors. The localization formula is derived from nonlinear least squares minimization over the unknowns of target range and bearing in polar coordinates. Computer simulation results are provided for the purpose of performance analysis. Constrained least squares minimization method with prior source location information is also discussed.

Hierarchical Structured Multi-agent for Distributed Databases in Location Based Services

  • Mateo Romeo Mark A.;Lee Jaewan;Kwon Oh-Hyun
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제14권3호
    • /
    • pp.17-22
    • /
    • 2005
  • Location management is very important in location-based services to provide services to the mobile users like banking, city guides and many more. Ubiquitous and mobile devices are the source of data in location management and its significant operations are update and search method. Some studies to improve these were presented by using optimal sequential paging, location area scheme and hierarchical database scheme. In addition, not all location services have the same access methods on data and it lead to difficulties of providing services. A proposed location management of multi-agent architecture is presented in this study. It shows the coordination of the agents on the distributed database of location-based services. The proposal focuses on the location management of the mobile object presented in a hierarchical search and update. Also, it uses a nearest neighbor technique for efficient search method of mobile objects.

  • PDF

Source Localization Techniques for Magnetoencephalography (MEG)

  • Kwang-Ok An;Chang-Hwan Im;Hyun-Kyo Jung;Yong-Ho Lee;Hyuk-Chan Kwon
    • KIEE International Transaction on Systems and Control
    • /
    • 제2D권2호
    • /
    • pp.53-58
    • /
    • 2002
  • In this paper, various aspects in magnetoencephalography (MEG) source localization are studied. To minimize the errors in experimental data, an approximation technique using a polynomial function is proposed. The simulation shows that the proposed technique yields more accurate results. To improve the convergence characteristics in the optimization algorithm, a hybrid algorithm of evolution strategy and sensitivity analysis is applied to the neuromagnetic inverse problem. The effectiveness of the hybrid algorithm is verified by comparison with conventional algorithms. In addition, an artificial neural network (ANN) is applied to find an initial source location quickly and accurately. The simulation indicates that the proposed technique yields more accurate results effectively.

  • PDF

Acoustic emission source location and noise cancellation for crack detection in rail head

  • Kuanga, K.S.C.;Li, D.;Koh, C.G.
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.1063-1085
    • /
    • 2016
  • Taking advantage of the high sensitivity and long-distance detection capability of acoustic emission (AE) technique, this paper focuses on the crack detection in rail head, which is one of the most vulnerable parts of rail track. The AE source location and noise cancellation were studied on the basis of practical rail profile, material and operational noise. In order to simulate the actual AE events of rail head cracks, field tests were carried out to acquire the AE waves induced by pencil lead break (PLB) and operational noise of the railway system. Wavelet transform (WT) was first utilized to investigate the time-frequency characteristics and dispersion phenomena of AE waves. Here, the optimal mother wavelet was selected by minimizing the Shannon entropy of wavelet coefficients. Regarding the obvious dispersion of AE waves propagating along the rail head and the high operational noise, the wavelet transform-based modal analysis location (WTMAL) method was then proposed to locate the AE sources (i.e. simulated cracks) respectively for the PLB-induced AE signals with and without operational noise. For those AE signals inundated with operational noise, the Hilbert transform (HT)-based noise cancellation method was employed to improve the signal-to-noise ratio (SNR). Finally, the experimental results demonstrated that the proposed crack detection strategy could locate PLB-simulated AE sources effectively in the rail head even at high operational noise level, highlighting its potential for field application.

관심영역 스캐닝기법을 이용한 레이더 펄스 발생원 위치 추정기법 (Source Localization Technique for Radar Pulse Emission by Using Scanning Method of Interest Area)

  • 최경식;김종필;원현권;박재현;김인규
    • 한국항공우주학회지
    • /
    • 제39권9호
    • /
    • pp.889-895
    • /
    • 2011
  • 최신의 항공기는 상대 항공기의 레이더에 검출되지 않기 위해 다양한 방법을 적용하고 있다. 레이더를 통해 감지가 어려운 적기의 존재 유무를 파악하고 적기와의 상대적인 거리 차이와 방위를 추정하기 위해 레이더 경보 수신기(RWR, Radar Warning Receiver)가 이용될 수 있다. 기존의 레이더 경보 수신기는 도달 각(AOA, Angle Of Arrival)을 구하고, 도달 각의 방향성으로 레이더 펄스가 발산된 위치를 추정하였다. 따라서 보다 정확한 위치를 추정하기 위해서 보다 정확한 도달 각을 구하는데 초점을 두었다. 반면 도달 각을 정확하게 구하더라도 레이더 펄스를 발산한 상대 항공기가 빠른 속도로 이동하는 경우 정확한 위치 추정은 어렵다. 본 논문에서는 레이더 펄스가 발산된 정확한 위치를 추정하기 위하여, 초고주파의 레이더 펄스 신호에서 저주파수 신호의 위상지연차를 이용하여, 관심 영역에 대한 스캐닝 기법으로 레이더 펄스가 발산된 위치를 추정하였다.

An Application of the Novel Techniques Detecting Partial Discharge Employable to GIS Using Optical Sensor

  • Ryu, Cheol-Hwi;Jung, Seung-Yong;Koo, Ja-Yoon;Yeon, Man-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.396-400
    • /
    • 2007
  • A novel technique has been proposed and related experimental works have been performed in order to detect the partial discharges and the location of the possible defects introduced into the Gas Insulated Switchgear. For this purpose, a prototype HY Pockels sensor has been developed and then employed in order to investigate its field applicability for finding the location of the defects using a 170kV GIS mock-up. Our proposed sensor enables us to measure the electric field variation due to the PD occurrence. In addition, the different PD patterns are observed, which might be dependant on the location and the distance of the sensor with respect to the PD source. Throughout this work, its linear response has been proved to be admissible as a function of the applied voltage. And also the position of the PD source might be distinguished by comparing the PD patterns.

탄소섬유보강판으로 보강된 철근콘크리트보의 균열 발생원 탐사를 위한 Acoustic Emission의 적용 (The Application of Acoustic Emission to detect the Crack Source Location for RC Beams Strengthened With Carbon Fiber Reinforced Plates)

  • 한상훈;이웅종;조홍동;나승일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.423-428
    • /
    • 2000
  • This Study was conducted to evaluate structural integrity and crack source location of RC structures strengthened with Carbon Fiber Reinforced Plates using acoustic, Four pont bending tests were carried out RC reinforced with C.F.R.P for the several strengthening specimens, the process of fracture was monitored by Acoustic Emission and duration and energy in AE parameters were analyzed. The location and propagation of crack could be easily determined by monitoring AE, which concluded that AE technique could be a very useful tool to evaluate structural integrity of reinforced RC structure.

  • PDF

배전설비 결함 검출을 위한 초음파 음원 위치추정 및 시각화 기법 (Ultrasonic Source Localization and Visualization Technique for Fault Detection of a Power Distribution Equipment)

  • 박진하;정하형;유준
    • 제어로봇시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.315-320
    • /
    • 2015
  • This paper describes the implemenation of localization and visualization scheme to find out an ultrasonic source caused by defects of a power distribution line equipment. To increase the fault detection performance, $2{\times}4$ sensor array is configured with MEMS ultrasonic sensors, and from the sensor signals aquired, the azimuth and elevation angles of the ultrasonic source is estimated based on the delay-sum beam forming method. Also, to visualize the estimated location, it is marked on the background image. Experimental results show applicability of the present technique.