• Title/Summary/Keyword: source location

Search Result 1,041, Processing Time 0.029 seconds

Analysis of Taxol and Related Compounds in Ullung Island Yew (Taxus cuspidata var. latifolia) (울릉도 주목(Tiaxus cuspidata var. latifolia)의 Taxol 및 관련 화합물의 함량분석)

  • 최명석;곽상수박용구유장렬
    • KSBB Journal
    • /
    • v.9 no.2
    • /
    • pp.186-190
    • /
    • 1994
  • The content of taxol and related compounds in various tissues of native yews( T. cuspidata var. latifolia) grown in 5 locations of Ullung Island were analyzed. A considerable range of vanation in the content was observed in the needle and bark collected from different trees located at the same area as well as at five different areas. Taxol content was much higher in the needle(0.017% on the dry weight basis) than those in the bark, whereas the content of 10-deacetyl baccatin III(10-DAB III) was slightly higher in the bark(0.073%), regardless of the location of the trees collected. Particuayly, the needle collected from the Hyunpo area, which located in North-west part of Ullung Island, contained the highest level of taxol(0.024%) exceeding the reported level in dried barks of Pacific yew and also somewhat higher level of its Precusor, 10-DAB III(0.049%). These results suggested that the needle of the yew at the Ullung Island could be suitable materials as a renewable source for the mass production of taxol.

  • PDF

Acoustic Characteristics of Underwater Noise from Uldolmok Tidal Current Pilot Power Plant (울돌목 시험조류발전소의 수중소음 특성 연구)

  • Ko, Myungkwon;Choi, Jee Woong;Yi, Jin-Hak;Jeong, Weonmu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.523-531
    • /
    • 2012
  • Recently, as a result of increasing concern about eco-friendly power, the demand for the power stations using environmentally friendly powers such as photovoltaic energy, wind force, tidal power, and tidal current has been increasing worldwide. Among these power stations tidal current power plant requires strong current generated by the topographic characteristics of the ocean floor. Uldolmok waterway producing very strong current is an ideal location for a tidal current power generation. However the occurrence of anthropogenic underwater noise generated by the tidal current power station may affect the marine environment. Therefore, it is necessary to evaluate the noise radiated from the station and predict the range influenced by the radiated noise. In this paper, the measurements of radiated noise spectrum level by the tidal current power station are presented, and the source level per unit area is estimated. Finally, the propagation properties of the radiated noise in the Uldolmok waterway is evaluated from the model simulation using the parabolic equation method, RAM.

Finite element modeling of corroded RC beams using cohesive surface bonding approach

  • Al-Osta, Mohammed A.;Al-Sakkaf, Hamdi A.;Sharif, Alfarabi M.;Ahmad, Shamsad;Baluch, Mohammad H.
    • Computers and Concrete
    • /
    • v.22 no.2
    • /
    • pp.167-182
    • /
    • 2018
  • The modeling of loss of bond between reinforcing bars (rebars) and concrete due to corrosion is useful in studying the behavior and prediction of residual load bearing capacity of corroded reinforced concrete (RC) members. In the present work, first the possibility of using different methods to simulate the rebars-concrete bonding, which is used in three-dimensional (3D) finite element (FE) modeling of corroded RC beams, was explored. The cohesive surface interaction method was found to be most suitable for simulating the bond between rebars and concrete. Secondly, using the cohesive surface interaction approach, the 3D FE modeling of the behavior of non-corroded and corroded RC beams was carried out in an ABAQUS environment. Experimental data, reported in literature, were used to validate the models. Then using the developed models, a parametric study was conducted to examine the effects of some parameters, such as degree and location of the corrosion, on the behavior and residual capacity of the corroded beams. The results obtained from the parametric analysis using the developed model showed that corrosion in top compression rebars has very small effect on the flexural behaviors of beams with small flexural reinforcement ratio that is less than the maximum ratio specified in ACI-318-14 (singly RC beam). In addition, the reduction of steel yield strength in tension reinforcement due to corrosion is the main source of reducing the load bearing capacity of corroded RC beams. The most critical corrosion-induced damage is the complete loss of bond between rebars and the concrete as it causes sudden failure and the beam acts as un-reinforced beam.

A study on the fast prediction of the fragmentation zone using artificial neural network when a blasting occurs around a tunnel (인공신경망을 이용한 터널 주변 폭파 시 파쇄영역의 빠른 예측에 관한 연구)

  • You, Kwang-Ho;Jeon, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.81-95
    • /
    • 2013
  • When collapse occurs due to explosion near a tunnel, fragmentation zone should be comprehended quickly to recover the function of the tunnel itself. In this study, a method to interpret explosion behavior and predict the fragmentation zone fast. For this purpose, the various 3D-meshes were generated using SolidWorks and explosion analyses were carried out using AUTODYN. The influence of explosion variables such as source location on fragmentation volume were examined by performing sensitivity analyses. Also, a training database for an artificial neural network analysis had been established and the optimal training model was selected, and the predicted results for fragmentation volume and radius were verified. The suggested method had demonstrated that it could be effective for the fast prediction of fragmentation zone.

PIV Measurement and Color Schlieren Observation of Supersonic Jets (PIV 및 컬러 쉴리렌 기법을 이용한 초음속 제트 관측)

  • Lee, Jae Hyeok;Zhang, Guang;Kim, Tae Ho;Kim, Heuy Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.604-605
    • /
    • 2017
  • The present work aims at visualization of the supersonic air jet flows discharged from C-D nozzles. In the present experiments, Prticle Image Velocimetry (PIV) was employed to specify the jet flow field quantitatively, and a color Schlieren optical method was applied to observe the same jets qualitatively. The $0.5{\mu}s$ duration of spark light source was used for Schlieren and it can be controled as $0.5{\mu}s$, $1{\mu}s$, $2{\mu}s$ and focusing mode. The convergent-divergent nozzles were used to generate the jet flow with the design Mach number of 2.0, 2.2. Nozzle pressure ratios (NPRs) were varied from 5 to 8. A good comparison of the jet size and shock location from the Schlieren images with the PIV quantitative values is obtained. The obtained images clearly showed the major features of the under-expanded jet, over-expanded jet, sound wave, turbulent eddies and so on.

  • PDF

Development of hybrid shielding system for large-area Compton camera: A Monte Carlo study

  • Kim, Jae Hyeon;Lee, Junyoung;Kim, Young-su;Lee, Hyun Su;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2361-2369
    • /
    • 2020
  • Compton cameras using large scintillators have been developed for high imaging sensitivity. These scintillator-based Compton cameras, however, mainly due to relatively low energy resolution, suffer from undesired background-radiation signals, especially when radioactive materials' activity is very low or their location is far from the Compton camera. To alleviate this problem for a large-size Compton camera, in the present study, a hybrid-type shielding system was designed that combines an active shield with a veto detector and a passive shield that surrounds the active shield. Then, the performance of the hybrid shielding system was predicted, by Monte Carlo radiation transport simulation using Geant4, in terms of minimum detectable activity (MDA), signal-to-noise ratio (SNR), and image resolution. Our simulation results show that, for the most cases, the hybrid shielding system significantly improves the performance of the large-size Compton camera. For the cases investigated in the present study, the use of the shielding system decreased the MDA by about 1.4, 1.6, and 1.3 times, increased the SNR by 1.2-1.9, 1.1-1.7, and 1.3-2.1 times, and improved the image resolution (i.e., reduced the FWHM) by 7-8, 1-6, and 3-5% for 137Cs, 60Co, and 131I point source located at 1-5 m from the imaging system, respectively.

Evaluation of dose distribution from 12C ion in radiation therapy by FLUKA code

  • Soltani-Nabipour, Jamshid;Khorshidi, Abdollah;Shojai, Faezeh;Khorami, Khazar
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2410-2414
    • /
    • 2020
  • Heavy ions have a high potential for destroying deep tumors that carry the highest dose at the peak of Bragg. The peak caused by a single-energy carbon beam is too narrow, which requires special measures for improvement. Here, carbon-12 (12C) ion with different energies has been used as a source for calculating the dose distribution in the water phantom, soft tissue and bone by the code of Monte Carlobased FLUKA code. By increasing the energy of the initial beam, the amount of absorbed dose at Bragg peak in all three targets decreased, but the trend for this reduction was less severe in bone. While the maximum absorbed dose per bone-mass unit in energy of 200 MeV/u was about 30% less than the maximum absorbed dose per unit mass of water or soft tissue, it was merely 2.4% less than soft tissue in 400 MeV/u. The simulation result showed a good agreement with experimental data at GSI Darmstadt facility of biophysics group by 0.15 cm average accuracy in Bragg peak positioning. From 200 to 400 MeV/u incident energy, the Bragg peak location increased about 18 cm in soft tissue. Correspondingly, the bone and soft tissue revealed a reduction dose ratio by 2.9 and 1.9. Induced neutrons did not contribute more than 1.8% to the total energy deposited in the water phantom. Also during 12C ion bombardment, secondary fragments showed 76% and 24% of primary 200 and 400 MeV/u, respectively, were present at the Bragg-peak position. The combined treatment of carbon ions with neutron or electron beams may be more effective in local dose delivery and also treating malignant tumors.

Analysis of Alkaloid Contents in Korean Plumyew [Cephalotaxus Koreana]: Variation with Location and Season (한국산 개비자 나무 [Cephalotaxus Koreana]의 알칼로이드 함량분석: 지역 및 계절에 따른 변화)

  • 김상익;최형균;송재영;김진현;이현수;홍승서
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.434-437
    • /
    • 2000
  • The contents and composition of alkaloids homoharringtonine, harringtonine, and cephalotaxine were determined in Korean native plumyew tree (Cephalotaxus koreana) collected from 17 different sites in Korea. The alkaloid contents of C. koreana varied with locations and plant populations from 11.8 mg/g to 195.2 mg/g of dry weight while C. koreana in southern area had higher alkaloid contents. The alkaloid compositions in C. koreana were highest with homoharringtonine (40%) and followed harringtonine (32%) and cephalotaxine (28%). Total alkaloids and homoharringtonine contents in needles were higher than those of stem by 2 fold. Alkaloid contents of C. koreana were the highest in winter, and the lowest in summer. Comparison of alkaloid contents and composition with other species of Cephalotaxus revealed that C. koreana was different to C. harringtonia, and contents of homoharringtonine were higher than other species. C. koreana could be potential source for homoharringtonine and related alkaloids.

  • PDF

Design and Implementation of Low-power RTLS Tag using Adaptive Blink (적응형 블링크를 이용한 저전력 RTLS 태그의 설계 및 구현)

  • Jung, Yeon-Su;Kim, Sae-Na;Baek, Yun-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.580-585
    • /
    • 2009
  • Real Time Locating Systems (RTLS) are used to track and identify the location of objects in real time using simple, inexpensive tags attached to or embedded in objects and readers that receive the wireless signals from these tags to determine their locations. A tag is powered an internal source such as a battery. The blink frequency of a tag affects the energy efficiency and the locating accuracy of RTLS. The mobility of a tag also affects the locating accuracy. In this paper, we introduce a RTLS tag design which improves the locating accuracy and the power efficiency. We propose an adaptive transmission-rate control algorithm using a motion sensor. By analyzing the signal pattern of the motion sensor, we can build a model to estimate the speed of the motion. Using this model, our algorithm can achieve better locating accuracy and lower power consumption than those of the conventional method. In our experiments, the number of transmission reduced as 40%, keeping similar locating accuracy.

Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices (RCD와 SPD의 접속 위치에 따른 보호협조)

  • Lee, Bok-Hee;Park, Hee-Yeoul;Shin, Gun-Jin;Bae, Gwan-Young;Ryu, Chun-Hyoung;Lee, Kang-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.