DOI QR코드

DOI QR Code

Evaluation of dose distribution from 12C ion in radiation therapy by FLUKA code

  • Soltani-Nabipour, Jamshid (Department of Medical Radiation Engineering, Islamic Azad University) ;
  • Khorshidi, Abdollah (Department of Medical Radiation Engineering, Islamic Azad University) ;
  • Shojai, Faezeh (Faculty of Engineering, Islamic Azad University, Science and Research Branch) ;
  • Khorami, Khazar (Department of Physics, Islamic Azad University, Central Tehran Branch)
  • Received : 2019.12.28
  • Accepted : 2020.03.11
  • Published : 2020.10.25

Abstract

Heavy ions have a high potential for destroying deep tumors that carry the highest dose at the peak of Bragg. The peak caused by a single-energy carbon beam is too narrow, which requires special measures for improvement. Here, carbon-12 (12C) ion with different energies has been used as a source for calculating the dose distribution in the water phantom, soft tissue and bone by the code of Monte Carlobased FLUKA code. By increasing the energy of the initial beam, the amount of absorbed dose at Bragg peak in all three targets decreased, but the trend for this reduction was less severe in bone. While the maximum absorbed dose per bone-mass unit in energy of 200 MeV/u was about 30% less than the maximum absorbed dose per unit mass of water or soft tissue, it was merely 2.4% less than soft tissue in 400 MeV/u. The simulation result showed a good agreement with experimental data at GSI Darmstadt facility of biophysics group by 0.15 cm average accuracy in Bragg peak positioning. From 200 to 400 MeV/u incident energy, the Bragg peak location increased about 18 cm in soft tissue. Correspondingly, the bone and soft tissue revealed a reduction dose ratio by 2.9 and 1.9. Induced neutrons did not contribute more than 1.8% to the total energy deposited in the water phantom. Also during 12C ion bombardment, secondary fragments showed 76% and 24% of primary 200 and 400 MeV/u, respectively, were present at the Bragg-peak position. The combined treatment of carbon ions with neutron or electron beams may be more effective in local dose delivery and also treating malignant tumors.

Keywords

References

  1. J. Soltani-Nabipour, M.A. Popovici, G. Cata-Danil, Residual nuclides produced by 290 MeV/u 12C ions beam in a liquid water target, Rom. Rep. Phys. 62 (1) (2010) 37-46, doi: n/a.
  2. A. Khorshidi, A. Rajaee, M. Ahmadinejad, M. Ghoranneviss, M. Ettelaee, Low energy electron generator design and depth dose prediction for microsuperficies tumors treatment purposes, Phys. Scripta 89 (9) (2014), 095001, https://doi.org/10.1088/0031-8949/89/9/095001.
  3. P. Azimi, A. Movafeghi, Proton therapy in neurosurgery: a historical review and future perspective based on currently available new generation systems, Int. J. Clin. Neurosci. 3 (2) (2016) 59-80, https://doi.org/10.22037/icnj.v3i2.13324.
  4. S. Malmir, A. Asghar Mowlavi, S. Mohammadi, Enhancement evaluation of energy deposition and secondary particle production in gold nanoparticle aided tumor using proton therapy, Int. J. Canc. Manag. 10 (10) (2017), e10719, https://doi.org/10.5812/ijcm.10719.
  5. G.L. Campos, T.P.R. Campos, Proposed parameters for a circular particle accelerator for proton beam therapy obtained by genetic algorithm, Braz J. Radiol. Sci. 2 (7) (2019) 1-15, doi: n/a.
  6. E.A. Krasavin, A.V. Boreyko, M.G. Zadneprianetc, E.V. Ilyina, R.A. Kozhina, E.A. Kuzmina, E.A. Kulikova, E.V. Smirnova, G.N. Timoshenko, S.I. Tiounchik, V.N. Chausov, The influence of DNA synthesis inhibitors on the biological efficiency of the modified Bragg peak proton beam, PEPAN Lett. 16 (2) (2019) 181-190, doi: n/a.
  7. A. Khorshidi, Accelerator-based methods in radio-material 99Mo/99mTc production alternatives by Monte Carlo method: the scientific-expedient considerations in nuclear medicine, J. Multiscale Model. (JMM) 11 (1) (2020) 1930001, https://doi.org/10.1142/S1756973719300016.
  8. J.S. Nabipour, A. Khorshidi, Spectroscopy and optimizing semiconductor detector data under X and ${\gamma}$ photons using image processing technique, J. Med. Imag. Radiat. Sci. 49 (2) (2018) 194-200, https://doi.org/10.1016/j.jmir.2018.01.004.
  9. A. Khorshidi, Neutron activator design for 99Mo production yield estimation via lead and water moderators in transmutation's analysis, Instrum. Exp. Tech. 61 (2) (2018) 198-204, https://doi.org/10.1134/S002044121802015X.
  10. A. Khorshidi, Gold nanoparticles production using reactor and cyclotron based methods in assessment of 196,198Au production yields by 197Au neutron absorption for therapeutic purposes, Mater. Sci. Eng. C 68 (2016) 449-454, https://doi.org/10.1016/j.msec.2016.06.018.
  11. A. Khorshidi, Radiochemical parameters of molybdenum-99 transmutation in cyclotron-based production method using a neutron activator design for nuclear-medicine aims, Eur. Phys. J. Plus 134 (2019) 249, https://doi.org/10.1140/epjp/i2019-12568-3.
  12. A. Khorshidi, A. Pazirandeh, Molybdenum transmutation via 98Mo samples using bismuth/lead neutron moderators, Europhys. Lett. 123 (1) (2018), 12001, https://doi.org/10.1209/0295-5075/123/12001.
  13. G. Battistoni, et al., The FLUKA code: description and benchmarking, in: AIP Conf. Proc., vol. 896, 2007, pp. 31-49. In Proceedings of the Hadronic Shower Simulation Workshop 2006, Fermilab 6-8 September 2006.
  14. P. Andreo, On the clinical spatial resolution achievable with protons and heavier charged particle radiotherapy beams, Phys. Med. Biol. 54 (2009) N205-N215, https://doi.org/10.1088/0031-9155/54/11/N01.
  15. T. Abe, T. Ohno, M. Koto, Y. Demizu, H. Suefuji, H. Tsuji, T. Okimoto, Y. Shioyama, J.I. Saitoh, K. Shirai, K. Nemoto, T. Nakano, T. Kamada, Japan Carbon-Ion Radiation Oncology Study Group. A multi-institutional retrospective study of carbon-ion radiotherapy for non-squamous cell malignant tumors of the nasopharynx: subanalysis of Japan Carbon-Ion Radiation Oncology Study Group study 1402 HN, Cancer Med. 7 (12) (2018) 6077-6083, https://doi.org/10.1002/cam4.1884.
  16. A. Khorshidi, Accelerator driven neutron source design via beryllium target and 208Pb moderator for boron neutron capture therapy in alternative treatment strategy by Monte Carlo method, J. Canc. Res. Therapeut. 13 (3) (2017) 456-465, https://doi.org/10.4103/0973-1482.179180.
  17. R. Reiazi, A. Norozi, M. Etedadialiabadi, A literature survey on costeffectiveness of proton beam therapy in the management of breast cancer patients, Iran. J. Cancer Prev. 8 (6) (2015), e4373, https://doi.org/10.17795/ijcp-4373.
  18. M. Ashoor, A. Khorshidi, L. Sarkhosh, Appraisal of new density coefficient on integrated-nanoparticles concrete in nuclear protection, Kerntechnik 85 (1) (2020) 9-14, https://doi.org/10.3139/124.190016.
  19. J. Soltani-Nabipour, A. Khorshidi, F. Sadeghi, Constructing environmental radon gas detector and measuring concentration in residential buildings, Phys. Part. Nucl. Lett. 16 (6) (2019) 789-795, https://doi.org/10.1134/S154747711906030X.
  20. G. Khaleghi, J. Soltani-Nabipour, A. Khorshidi, F. Taheri, Design of band-pass filters by experimental and simulation methods at the range of 100-125 keV of X-ray in fluoroscopy, Int. J. Biosci. Technol. (2019), https://doi.org/10.1504/IJBET.2019.10025733. Inderscience Publishers - linking academia, business and industry through research In press.
  21. A. Khorshidi, B. Khosrowpour, S.H. Hosseini, Determination of defect depth in industrial radiography imaging using MCNP code and SuperMC software, Nucl. Eng. Technol. (2020), https://doi.org/10.1016/j.net.2019.12.010. In press.
  22. A. Khorshidi, Assessment of SPECT images using UHRFB and other low-energy collimators in brain study by Hoffman phantom and manufactured defects, Eur. Phys. J. Plus 135 (261) (2020), https://doi.org/10.1140/epjp/s13360-020-00238-6. In press.
  23. A. Khorshidi, A. Abdollahi, A. Pirouzi, S.H. Hosseini, Band pass filter plan in fluoroscopy for high energy range, SN Appl. Sci. 2 (2020) 90, https://doi.org/10.1007/s42452-019-1885-2.
  24. N. Banihashemi, J. Soltani-Nabipour, A. Khorshidi, H. Mohammadi, Quality control assessment of philips digital radiography and comparison with spellman and samsung systems in Tehran Oil Ministry Hospital, Eur. Phys. J. Plus 135 (2020), 269, https://doi.org/10.1140/epjp/s13360-020-00275-1. In press.
  25. A. Khorshidi, Exploration of adiabatic resonance crossing through neutron activator design for thermal and epithermal neutron formation in $^{99}Mo$ production and BNCT applications, Canc. Biother. Rad. 30 (8) (2015) 317-329, https://doi.org/10.1089/cbr.2014.1734.
  26. H. Tsujii, T. Kamada, A review of update: clinical results of carbon ion radiotherapy, Jpn. J. Clin. Oncol. 42 (8) (2012) 670-685, https://doi.org/10.1093/jjco/hys104.
  27. Y. Kumamoto, Y. Noda, Y. Sato, T. Kanai, T. Murakami, Measurements of neutron effective doses and attenuation lengths for shielding materials at the heavy-ion medical accelerator in Chiba, Health Phys. 88 (5) (2005) 469-479, https://doi.org/10.1097/01.hp.0000154026.39382.36.
  28. K. Gunzert-Marx, D. Schardt, R.S. Simon, Fast neutrons produced by nuclear fragmentation in treatment irradiations with 12C beam, Radiat. Protect. Dosim. 110 (1-4) (2004) 595-600, https://doi.org/10.1093/rpd/nch138.
  29. A. Khorshidi, Molybdenum-99 production via lead and bismuth moderators and milli-structure-98Mo samples by the indirect production technique using the Monte Carlo method, Phys. Usp. 62 (9) (2019) 931-940, https://doi.org/10.3367/UFNe.2018.09.038441.

Cited by

  1. Assessment of absorbed dose in deformed breast tissue by Monte Carlo simulation vol.2, pp.8, 2020, https://doi.org/10.1007/s42452-020-3113-5
  2. Bragg-curve simulation of carbon-ion beams for particle-therapy applications: A study with the GEANT4 toolkit vol.53, pp.8, 2021, https://doi.org/10.1016/j.net.2021.02.011
  3. 몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가 vol.44, pp.4, 2020, https://doi.org/10.17946/jrst.2021.44.4.359