• Title/Summary/Keyword: sound insulation

Search Result 453, Processing Time 0.026 seconds

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구)

  • Kim, Sung Soo;Sohn, Jang yeul
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.

The Aging Characrteristic Analysis of Mica-Epoxy Insulation Materials (마이카-에폭시 절연재료의 열화특성분석)

  • Yoo, Yeong-Sik;Kim, Hee-Gon;Song, Woo-Chang;Lee, Jae-Hyung;Park, Yong-Kwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.82-89
    • /
    • 1998
  • The experimental results using the X -ray technique, the position and structure of mica crystal are not observed the phase change of aging and sound specimen respectively. However, We could observe the intensity difference of crystal element in both atmospheres. The analysis of mica-epoxy materials by optical microscope are shown that the each surface of sound and aging specimens are different in both atmospheres Also, the experimental results have shown that the potassium ions of mica cristal are substituted by hydrogen ions at boundary area of mica-epoxy and/or mica-mica. On components made of mica, a potassium ion of big atomic radius, is replaced by hydrogen ion of small atomic radius. The voids are created by the difference of radius progressed by combined stresses. Through these phenomena, it has been proposed that the conductive layers made of potassium enable the voids to form and the cracks to create by high electric field.

  • PDF

Recycling of Sound Insulation Headliner Waste Material (흡음재 폐기물의 재활용 방안)

  • Hong, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.3089-3095
    • /
    • 2013
  • The headliner was made of polyurethane(PU) and glass fiber(GF) composite materials are widely used as a sound insulation material. A large amount of waste materials occurs as a by-product in the headliner manufacturing process. In order to efficiently reuse the headliner waste materials, separation process of the components are very necessary. According to the results of thermal analysis, weight loss showed increase in the order polyurethane foam> non-foaming polyurethane> non-woven fabric> 1st layer> glass fiber in the range of up to $400^{\circ}C$. Analysis of the DSC characteristics, HDPE, LLDPE, PP, and Master Batch by adding additives the wasted scrap. As a result, except for the PP, there was no exothermic transition due to the crystallization.

Analysis of the Indoor Environmental Characteristics of Educational Facilities (Case Study of Thermal and Acoustical Environment of Elementary School by Field Measurement) (교육시설의 실내환경 특성 분석에 관한 연구 (초등학교의 열 및 음환경 실측조사에 의한 사례연구))

  • Cho, Min-Kwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.59-65
    • /
    • 2007
  • This study is to propose the basic data for deciding remodeling of wornout educational facilities. In order of it, the indoor environmental standard, the actual conditions of thermal environment and sound insulation of walls were examined through field measurement in the subjected open elementary school(J school) and modernization model of elementary school(Y school) which they are located in Seoul. As the result, standard for indoor environmental factors of educational facilities which is established by Ministry of Education is not subdivided into indoor environmental performances considering usages and characteristics of classrooms for comfortable indoor environment. The vertical temperature difference in general classroom and in open classroom showed to be $11.2^{\circ}C$ and $12.1^{\circ}C$ respectively, while indoor temperature of special classroon was, on the whole, higher than that of any other classroom due to its specific heat flux of wall materials. The sound insulation performance of the masonry brick wall of classroom satisfied the minimum standard of AIJ, Architectural Institute of Japan, in the open elementary school and the modernization model of elementary school. That is to say, the movable partition wall between the classroom and the corridor disturbed students in their class in the open school.

The Study for Vibro-acoustic Noise Analysis in the Fuselage of Regional Turboprop Airplane (중형항공기 동체 소음해석 기법 연구)

  • Park, Illkyung;Kim, Sungjoon;Jung, Jinduck
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.3
    • /
    • pp.44-50
    • /
    • 2012
  • The noise reduction is important one of considerations in the process of a civil aircraft development program. External noise sources are classified into an air-born source and a structure-born source. Among these noise sources, the most affected noise source into a cabin is the air-born noise source from an engine or propeller. The external noise is transmitted into the cabin through the fuselage structure of airplane which are composed of an fuselage structure, an interior trim panel and an acoustic insulation layer between an fuselage structure and an interior trim panel. Therefore, appropriate fuselage structure and acoustic insulation layer is very important to reduce the internal noise level. In this paper, the vibro-acoustic coupled analysis of the cabin noise of the 80~90 seats regional turboprop aircraft is carried out to validate the acoustic analysis method using Direct BEM and FEM. The sound pressure level onto the fuselage skin is acquired by fan-source noise analysis using BEM, and which sound pressure is used as acoustic noise source in vibro-acoustic noise analysis for cabin noise analysis using FEM.

A Study on the Floor Impact Sound Insulation Performance of Apartments depending on the Damping Materials (완충구조에 의한 공동주택 바닥충격음 차단성능 변화 연구)

  • Gi, No-Gab;Song, Min-Jeong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.79-82
    • /
    • 2005
  • This study aims to propose fundamental data for development of noise reduction system that is applied to classification for light-weight impact sound. For this reason, eight types of damping materials were constructed in new construction field. Comparison and analysis among the reduction materials were carried out on the acoustical characteristics through test. In the end, the suitability as a damping material was evaluated by the analysis.

  • PDF

Effects of IACC and its Variation on Annoyance of Heavy-weight Floor Impact Sounds (중량충격음 어노이언스 반응에 대한 IACC 변화의 영향)

  • Kumar P. Senthil;Sato, Shin-ichi;Jeon Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.626-630
    • /
    • 2006
  • This study investigates the effects of Interaural Cross-correlation(IACC) and its variation on annoyance of the heavy-weight impact sounds. Subjects evaluated the annoyance of the heavy-weight floor impact sounds recorded in rooms of apartments which have different sound insulation treatments; furnished and occupied conditions are characterized by the ACF/IACF factors. A paired comparison test was conducted using the impact sound sources whose IACC and variation of IACC values were different. It was found that IACC is inversely correlated with the scale value(r=-0.62) whereas the variation of IACC is not(r=-0.34). On the contrary, ${\Phi}(0)$ is highly correlated with scale value of annoyance and ${\Phi}(0)$ is need to be controlled as constant to find the effect of IACC on annoyance.

  • PDF

Evaluating the Vibrational Characteristics of Floor Impact Noise in Different Structural Elements of an Apartment House (바닥충격에 의한 공동주택의 바닥, 벽, 천장의 진동 및 소음방사특성 연구)

  • Lee, Byung-Kwon;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.480-485
    • /
    • 2002
  • The overall noise reduction was compared in regard to the vibrational characteristics of floor impact noise in a multi story residential building which has several noise reduction treatments. The vibration through its structural elements such as wall, floor and ceiling and sound emitting were investigated for each insulation treatment. It was found that, in case of heavy-weight impact noise, the vibration energy is emitted mostly from ceiling, but for the light-weight impact noise, most of the energy comes through ceiling and walls. That is, the vibration of a ceiling is the main factor that determines the frequency characteristics of the transmitting noise to lower floors.

  • PDF

A Survey on Foreign and Domestic Interior Noise Criteria for Walls and Floors (공동주택 내부소음 기준과 바닥 및 벽체 차음성능 기준 고찰)

  • Kim, Sun-Woo;Song, Min-Jeong
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.37-44
    • /
    • 2004
  • In this study, foreign and domestic noise criteria on walls, floors, and water supply facilities were reviewed and the results are as follows : regulation can be divided two things, one is on thickness the other is sound insulation performance. Green Building regulation based on the law and this have sound classification systems. Since these regulations are not established in Korea. The noise regulation on water supply-drain facilities and domestic guideline on interior noise level is needed. Foreign regulations are stricter than those of ours. And those has sound classification system for the better acoustic condition of inhabitants'.

The Noise property and Its improvement of the Turbo Compressor (터보압축기의 소음특성 및 개선방안)

  • Chun, Kwang-Wook;Shin, Bum-Sik;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.282-287
    • /
    • 2009
  • In this paper, 3-stage centrifugal turbo compressor was measured and analyzed numerical simulation for find noise source and was reduced noise with changing designs. For this purpose, it was measured noise level and was analyzed noise frequency at each stage. In order to Find where is noise source, the study was investigated about structure borne noise by using modal analysis and also was checked sound radiation and leakage of noise at inlet and outlet by result of sound intensity. In order to reduce of noise, sound insulation rings were maded and were adhered at joint and noise reduction effects were verified by measurement and numerical simulation. From the analysis results of leakage of noise, this study presented new joint designs, also it was verified by result of numerical simulation.

  • PDF