• Title/Summary/Keyword: sound insulation

Search Result 453, Processing Time 0.031 seconds

Experimental Study of Floor Impact Sound Insulation by the Finishing Materials and Porous Ratio of Insulations of Floor Structure in Mock-up Test Room (모형실험실에서 바닥충격음 완충재의 발포율 및 바닥마감재의 변화에 따른 충격음 차단성능에 대한 실험적 연구)

  • 김태희;오진균;신일섭;조창근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.756-759
    • /
    • 2003
  • It is increasing the interest on the comfortable dwelling environment and the efforts to solve the problem of the floor impact noise in apartment houses have been realized, as a result numerous products have been made. The purpose of this study is to investigate the sound insulation performances according to foaming rate of floor impact noise insulators and flooring coverings in Mock-up Test Room. The test results of impact insulation performance for each floor impact noise insulators is that double structure of insulator is excel than one in low-middle frequency band and as foaming rate go up, the sound insulation performance is improved.

  • PDF

A Study on Estimation of Uncertainty in Measurement of Light Impact Sound Insulation of Floors (공동주택 경량바닥충격음 측정불확도 추정에 관한 연구)

  • Go, Jong-Chul;Lee, Jong-In;Kim, Hyun-Bae;Lee, Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1409-1416
    • /
    • 2006
  • In measuring, uncertainty in measurement is essential to improve measuring reliability. Currently, however, in measuring impact sound insulation of floors, there are no guidelines to estimate uncertainty in measurement. In addition, the concept of uncertainty in rating is required to recognize the relation between measuring and rating. Therefore, through this paper, the efforts have been made to establish uncertainty in measurement and rating of light impact insulation of floors. The result of estimating of uncertainty in measurement and rating in our laboratory is considered reliable, considering ${\pm}0.46{\sim}1.44dB$ of uncertainty in measurement and 1 dB of uncertainty in rating.

  • PDF

Comparison of Performance of Sound Insulation Panel for Transformer (변압기용 차음판의 성능 비교)

  • Jeong, H.E.;Choi, B.K.;Kim, H.J.;Gu, D.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1302-1305
    • /
    • 2006
  • Recently, demands for the reduction of noise generated by transformers have been increasing. Accordingly the noise of transformer occasion displeasing to residents therefore the transformer needs to decrease of noise. One method of reduction such a noise is to build a free-standing enclosure of concrete and steel plates around the transformer, however, this method has some disadvantages, for example, a lage area is needed for equipment installation. In the paper, the vibration and noise effect which is transferred from reinforce channel to insulation panel generated by transformer have been identified for the several kinds of insulation panel and damping sheet experimentally.

  • PDF

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

The estimation of Sound insulation performance by the balcony windows in the reverberant room and anechoic room (실험실에서의 발코니창호 차음성능 평가)

  • Kim, Tae-Hee;Shin, Il-Seop;Cho, Chan-Geun;Oh, Jin-Kyun;Kim, Nam-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.956-959
    • /
    • 2007
  • The extension of a road system result from construction of the builling near the noise source as the roads, railroads. Many people who have a living space near the road are damaged by the noise generated the road system. Therefore, the damage will be reduced by the appropriate measure like putting some distance between receiver and source. The windows are weak among the building materials. But mainly we uses the windows as building exterior materials. So the sound insulation of the balcony windows was measured and compared.

  • PDF

Recent trends of classification of ships by shipping class: (국제 선급의 선박 품질등급화 최근동향: 차음성능)

  • 강현주;김재승;김봉기
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.209-212
    • /
    • 2002
  • This article introduce Comfort Class V released by Dnv The Class has an objective of classifying ships by noise and vibration levees. It is apparent that noise criteria listed in the Class can not be satisfied without special efforts to enhance sound insulation performance in cabins. Accordingly, panel makers should develope panels which have very high sound insulation performance enough to satisfy the criteria. Also, due to large difference of sound insulation performance between cabin and laboratory, it is necessary that ship yards should improve the method for installing cabins.

  • PDF

Sound-Insulation Performance of Aluminum Extruded Panel by Charging Foam in a High-speed Train (고속철도차량용 알루미늄 압출재의 차음성능에 대한 폼 충전효과)

  • Lee, Joong-Hyeok;Park, In-Seok;Kim, Seock-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.582-585
    • /
    • 2012
  • The aluminum extruded panel used for a high speed train shows the largest contribution to sound insulation performance of the train body. However, comparing with the flat panel having the same weight, the transmission loss falls sharply in the local resonance frequency band. Such fall of transmission loss can be improved by increasing the damping of local resonance. This study examines the charging effect of an urethane foam on the aluminum extruded panel of a high speed train. We charged the urethane foam with different mass density and in different way in the core part of the extruded panel. We measure the transmission loss and compare the sound insulation performance according to the density and charging method. Finally, Improvement effect of the transmission loss is compared and analysed in aspect of weight increment.

  • PDF

Sound Insulation Design of the Corrugated Steel Panel Considering Local Resonance (국부 공진을 고려한 주름강판의 차음 설계)

  • Kim, Seock-Hyun;Lee, Hyun-Woo;Kim, Jung-Tae;Kim, Jae-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.7
    • /
    • pp.672-676
    • /
    • 2010
  • In a railway vehicle, corrugated steel panel is widely used for the floor structure because of its high bending stiffness and light weight. However, this panel shows lower sound insulation performance than that of the flat plate with the same weight. Especially, in a particular frequency region, transmission loss(TL) rapidly decreases and it results in the deterioration of sound insulation performance of the overall floor structure. This study identifies that the severe decrease in TL is caused from the local resonance of the periodic corrugated structure. TL decrease by local resonance is investigated by experiment and finite element analysis. Finally, design modification of the corrugation is proposed to improve TL and the effect is verified by experiment.

Review of laboratory test facilities for measuring impact sound insulation in Korea. (바닥충격음 관련 국내 실험실 현황 및 고찰)

  • 장길수;정갑철;김재수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.234-238
    • /
    • 2001
  • This study aims to review the present conditions of domestic laboratory test facilities for measuring impact sound insulation. The result will be useful to establish the new Korean Standard to coincide with ISO 140-6.

  • PDF

Analysis Sound Insulation Performance of a Corrugated Steel Panel Through Modal Density (주름 강판의 모드 밀도에 따른 차음 성능 분석)

  • Kim, Seockhyun;Byeon, Jun Ho;Lee, Joong Hyeok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.12
    • /
    • pp.1061-1066
    • /
    • 2016
  • Corrugation of a corrugated panel dramatically increases the bending stiffness per weight. However, corrugated panels show lower sound insulation performance than that of the flat plate having the same weight. Especially, in a particular frequency region, the sound transmission loss significantly decreases. Main reason of the problem is known as the local resonance. A number of local resonance modes occur above a certain frequency band and modal density rapidly increases. In this study, we investigate the relation of the sound transmission loss and the modal density. Finally, we propose a design methodology in terms of the modal density to improve the sound insulation performance of the corrugated panels without weight increase.