• 제목/요약/키워드: smoke production rate

검색결과 57건 처리시간 0.029초

실대화재시험의 화재성능 등급분류에 관한 연구 (Study on the combustion performance's classification system for large scale fire tests)

  • 박계원;임홍순;정재군
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.99-104
    • /
    • 2008
  • The combustion properties of sandwich panels were tested and analyzed according to ISO 13784-1(Room Corner Test for Sandwich panel building systems) test method for the purpose of establishing the classification of reaction to fire performance. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, and so on, were analyzed for specific four materials about sandwich panel systems on each 5 times, totally 20 times. Finally, elements for Classification system were suggested and evaluations for those elements were made.

  • PDF

샌드위치 패널 연소특성 분석을 위한 실대규모 화재시험(ISO 13784-1) 적용 (Applying to ISO 13784-1 fire tests for analyzing the combustion properties of sandwich panel systems)

  • 임홍순;박계원;정재군;이길용;김정욱;정정호;이우석;김운형
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.112-116
    • /
    • 2008
  • The combustion properties of sandwich panels were tested according to ISO 13784-1(Room Corner Test for Sandwich panel building systems) method to supplement ISO 9705 Room corner test, and analyzed comparatively. Several variables including heat release rate, smoke production rate, FIGRA, SMOGRA, thermal configuration, visual check lists and so on, were analyzed for four materials on sandwich panel systems. Finally, Fire performances of test results on each material by ISO 13784-1 are categorized by applying to the classification system of both EN 13501-1 and Eurefic research program

  • PDF

위성사진으로 본 북한의 시멘트 산업 (North Korea Cement Industry in Satellite Imagery)

  • 백철승;서준형;조진상;안지환;조계홍
    • 세라미스트
    • /
    • 제22권2호
    • /
    • pp.198-214
    • /
    • 2019
  • The possibility of economic exchange with North Korea is increasing, but there is still a shortage of information of cement industry, which occupies the largest proportion of North Korean construction material industry. Therefore, this study researched the status of cement production facility management using satellite photographs of 16 cement factories in North Korea, and examined the operating status of North Korean cement industry by observing smoke discharged from the chimneys of the cement production facilities. When the satellite photographs were analyzed, it was observed that the monthly stack fog ratio of the North Korean cement factories was 55% in 2016, 60% in 2017 and nearly 65% in 2018. This demonstrates that the average operating ratio has been increasing continuously. However, the operation rate of the five major cement factories reaches the limit, actual cement production is estimated to have maintained the previous level or small increased.

지하구 케이블의 연소특성 실험 (Experiments on the Behavior of Underground Utility Cable in Fire)

  • 박승민;김운형;윤명오
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.75-80
    • /
    • 2002
  • 지하공동구에 사용되는 케이블의 연소특성 중 열방출량과 연기 유독성 실험을 수행하였다. 열 방출량 실험은 22.9 kv 전력용 케이블을 대상으로 ISO 9705 규격의 공간에서 수행하였으며 유독성가스의 정량적 위험성 평가를 위하여 NES 713(British-Naval Engineering Standard)을 적용하였다. 실험 결과 측정높이 1.2 m를 기준으로 계산한 케이블의 열 방출 율은 60 kW로 예측되었다. 한편, 케이블의 연기유독성을 위한 NES 실험 결과, 인체에 치명적인 CO의 경우 30분 노출시 사망에 이를 수 있고 의식불명상태가 될 수 있는 수준으로 판정되었다

건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구 (A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings)

  • 홍성호;최문수
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

화재성능이 확보된 재생 폐자원 단열재의 활용 연구 (Study on application of recycled insulation-panel with fire-safety performance)

  • 박계원;정재군;김학용
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.167-170
    • /
    • 2010
  • This study is aiming at analyzing correlation between flashover's time and maximum smoke production rate's time on sandwich panel specimens. For this analysis, KS F ISO 137481-1 has been performed for 23 kinds of sandwich panels which mainly consist of EPS, PIR, PUR, Glass wool and so on. KS F ISO 13784-1 represents real scale reaction-to-fire test and focuses on measuring flashover phenomenon rather than other tests as like ISO 5660-1 and SBI.

  • PDF

실대규모 화재시험(ISO 13784-1)을 적용한 샌드위치 패널 시스템의 연소성능 분류 (Classification of Reaction-to-Fire's Performances on Sandwich Panel Systems by Applying to ISO 13784-1 Fire Tests)

  • 박계원;임홍순;정재군;이길용;김정욱;정정호;이우석;김운형
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.20-26
    • /
    • 2009
  • 본 연구에서는 ISO 9705(room corner test)에 의한 샌드위치 패널 화재 시험방법을 보완한 ISO 13784-1(room corner test for sandwich panel building systems) 시험방법을 적용하여 샌드위치 패널연소특성 및 성능을 분석하였다. 4종의 샌드위치 패널을 시험체로 선택하였으며, 시험 후 열방출율, 연기 발생율, FIGRA, SMOGRA 결과값을 중심으로 각 패널의 연소 성능을 분석하였으며, 최종적으로 유럽 Eurefic Research Program 및 EN 13501-1에서 제시하는 분류기준에 적용하여 등급분류를 시도하였다.

중소형 화재시험(ISO 5660-1 및 EN 13823)을 이용한 샌드위치패널 연소성능 분석 (Analysis on the Reaction-to-fire's Performance of Sandwich Panel Systems by using ISO 5660-1 and EN 13823 Fire Tests)

  • 박계원;임홍순;정재군;김운형
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.33-39
    • /
    • 2009
  • 본 연구에서는 ISO 5660-1(cone calorimeter test)과 EN 13823(Single Burning Item;SBI)에 의해 샌드위치패널에 대한 화재연소성능이 비교 분석되었다. 4종의 국내 샌드위치패널(심재 및 패널재)에 대해 착화시간, 열방출율, 연기발생율, 산소소모율 등과 같은 변수들이 측정되었다. 또한, 각 종류의 패널에 대한 연소특성이 시험방법별 및 소재별로 분석되었으며, 최종적으로 일본, 캐나다, 유럽 EN 1350-1의 화재성능 등급분류기준에 의해 검증되었다.

현장지휘관 훈련 콘텐츠 개발을 위한 주거목적시설 대표 가연물 실물화재시험 (Fire Tests for Representative Combustibles in Residential Facilities for the Development of Field Commander Training Content)

  • 문민호;양소연;한국일;이지희;김형준
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.22-29
    • /
    • 2020
  • 본 연구에서는 개발 중인 현장지휘관 훈련 콘텐츠에 적용될 화재상황의 현실성 및 전문성 확보를 위하여 선행연구에서 선정한 7개 화재유형별 중 주거목적시설의 대표 가연물 화재실험을 통해 화재양상 및 열방출량, 연기발생량을 분석하였다. 측정결과 최대 열방출량은 소파가 728.6 kW로 가장 높게 측정되었으며, 다음으로는 매트리스+전기장판, 책상+의자, TV, 매트리스 순으로 나타났다. 총열방출량의 경우 소파가 226.2 MJ, 총 연기발생량은 경우 매트리스+전기장판이 2,259.5 ㎡로 가장 많이 발생하였다. 본 연구에서는 가연물의 화재양상 및 특성에 주안점을 두고 시험수행을 하였다는 한계점이 있으며, 추후 다양한 데이터 확보와 FDS를 활용한 시뮬레이션 평가가 이루어져야 할 것으로 판단된다.

GUDN/BTATz를 적용한 친환경추진제 특성 연구 (A Study on Characteristic of Eco-friendly Propellant Using GUDN/BTATz)

  • 전수아;원종웅;박성준;박정호;최성한
    • 한국추진공학회지
    • /
    • 제24권4호
    • /
    • pp.41-47
    • /
    • 2020
  • 본 연구에서는 염소가스 등 유해가스의 발생을 줄이고 질소가스 방출을 증가시키는 친환경 추진제 조성개발을 목표로 한다. 이에 고체 추진제에 일반적으로 사용되는 AP(Ammonium Perchlorate)와 Al(Aluminium)를 대신하여 저탄소 고질소 물질인 GUDN(N-Guanylurea dinitramide)과 BTATz(3,6-bis(1H-1,2,3,4-tetrazol-5-ylamino)-1,2,4,5-tetrazine)를 사용하였다. 제조된 추진제는 기계적 및 연소 특성, 성능 그리고 AGARD 연기등급을 분석하였다. AP/Al 추진제에 비해 GUDN/BTATz추진제는 기계적 성질과 연소 속도가 감소하는 경향을 나타내었다. 또한, 4인치표준모타 제작 후 지상연소 시험 결과 GUDN/BTATz추진제 연소 시 성능은 감소하였으나, 염소가스 등의 유해 가스를 줄여 2차 연기 등급도 개선됨을 확인할 수 있었다.