• Title/Summary/Keyword: smoke generator

Search Result 33, Processing Time 0.02 seconds

A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors (연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구)

  • Son, Geun­Sik;So, Soo­Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.236-244
    • /
    • 2021
  • Purpose: The purpose of this study is to develop IoT multi-fire detectors combined smoke/carbon monoxide/heat and wireless IoT communication and to confirm the detect performance by smoke generator fire test and cotton wicks fire test. Method: The IoT multi-fire detector combined smoke and CO and combined smoke and heat were experimented the detect performance by smoke generator test and fire test of cotton wicks. And the case of fire alarm was checked. Result: The IoT multi-fire detector combined smoke and CO rung the alarm at the fire test of cotton wicks, did not ring the alarm at the smoke generator test. In comparison, the IoT multi-fire detector combined smoke and heat did not ring the alarm both at the smoke generator test and the fire test of cotton wicks. Conclusion: The IoT multi-fire detector combined smoke and CO detected the only smoke including the carbon monoxide and the IoT multi-fire detector combined smoke and heat did not ring the alarm for lack of heat. As a result, when the developed IoT multi-fire detector was detected the signal more than the set point, the fire alarm was sounded through cotton wicks fire test and smoke generator.

Burning Characteristics of Smoke Generator of Pesticides Depending on Combustible Carrier and Formulation Type (제형과 가연성 담체에 따른 농약 훈연제의 연소 특성)

  • Lim, He-Kyoung;Kim, Yong-Whan;Cho, Kwang-Yun;Yu, Ju-Hyun
    • Applied Biological Chemistry
    • /
    • v.47 no.3
    • /
    • pp.325-331
    • /
    • 2004
  • In order to study the effect of formulation type on the burning characteristics of smoke generator, fenarimol smoke generators containing the powdered rice chaff as a combustible carrier were prepared by molding the kneaded mixtures into various shapes. Smoke generators containing wood flour as a combustible carrier were also prepared and compared with smoke generators containing rice chaff. All the fenarimol smoke generators moulded into powders, granules, and rods continuously burned out when the sodium chlorate content exceeded 11%. Regardless of their types, the highest smoking rate of fenarimol was observed with more than 13% of sodium chlorate. The smoking rate of active ingredient followed with the increasing order of powder (64.5%) < granule (78.4%) < rod (90.9%). The smoke rod was robust, easy to ignite, and showed the highest smoking rate among the tested formulations. When the mixture of wood flour and anti-flame agent was used as a combustible carrier, the burning rate was so slow that wood flour formulation seemed to be more suitable to a slow-burning fumigant rather than smoke generator.

A study of the smokeless liner formulation and smoke characteristics (무연 라이너 조성 및 연기 특성 연구)

  • 유지창;류문삼;백국현;류백능
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.19-27
    • /
    • 2002
  • The smokeless liner, was required to propulsion system of gas generator, was developed by appling oxamide as a filler and HTPB system as a binder. Relative quantities of smoke produced during burning of liner by propellant combustion was measured by using smoke chamber. The smoke of the smokeless liner containing 50% of oxamide as filler was reduced to 1/10 as compared with conventional liner containing silica as filler. This result was showed by ground test of gas generator.

Experiments of Smoke Behavior in an Underground Subway Station (지하역사에서의 화재연기거동 실험)

  • Kim, Dong-Hyeon;Jang, Yong-Jun;Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

Practical Usability of Smoke Generator Containing Rice Chaff as a Combustible carrier (왕겨를 가연성 담체로 하는 훈연제의 실용성 연구)

  • Lim, He-Kyoung;Choi, Gyung-Ja;Park, No-Jung;Kim, Yong-Whan;Cho, Kwang-Yun;Yu, Ju-Hyun
    • Applied Biological Chemistry
    • /
    • v.47 no.3
    • /
    • pp.321-324
    • /
    • 2004
  • Smoke rods were prepared for 2 insecticides and 5 fungicides using powdered rice chaff as a combustible carrier, and their burning characteristics were investigated. The distribution of active ingredient was investigated after the application of the granular smoke generator containing fenarimol in the connected vinyl plastic house growing cucumber. The protective effects of fungicide smoke generators were evaluated against cucumber gray mold (Botrytis cinerea) and tomato late blight (Phytophthora infestans), and compared with commercial wettable powders. Smoke rods containing powdered rice chaff showed high smoking rates of AI that were higher than commercial smoke pellets. The deposition of fenarimol on the ground of vinyl plastic house was $26.2{\pm}7.7\;ng/cm^2$ when averaged from 9 sites, and application uniformity was found. Also, the protective effects of 5 fungicidal smoke rods against plant diseases were so similar to the commercial wettable powders with no phytotoxicity that smoke rod formulations containing rice chaff as a combustible carrier could be used as an effective formulation for pesticides.

Effect of Oxidizing Agents on the Burning Characteristics of Smoke Rod of Pesticides Using Rice Chaff as a Combustible Carrier (왕겨를 가연성 담체로 하는 봉상 농약 훈연제의 연소성에 미치는 산화제의 영향)

  • Lim, He-Kyoung;Kim, Yong-Whan;Cho, Kwang-Yun;Yu, Ju-Hyun
    • Applied Biological Chemistry
    • /
    • v.47 no.3
    • /
    • pp.332-338
    • /
    • 2004
  • An investigation in search of the best oxidizing agent for smoke generators using rice chaff as a combustible carrier was carried out. Smoke rods formulated with active ingredients (AIs) such as inorganic oxidizing agents, glue, and powdered rice chaff, showed constant and high burning rate and high smoking rate on 11 kinds of pesticides. Sodium chlorate was the most suitable oxidizing agent for smoke rod. Even though the sodium chlorate content of the formulation showing the highest smoking rate of AI was variable to pesticides, the smoking rate appeared to increase as the burning rate increased. Active ingredients in smoke generator using rice chaff as a combustible carrier were stable for 60 days when stored at $50^{\circ}C$. An apparatus designed for smoke trapping was useful to collect smoked active ingredients.

Visualization of Smoke Flow in the Subway Fire (지하철 화재발생시 역사내 화재연기 거동 가시화 연구)

  • Choi Chang Jin;Jung Hae Gon;Kim Sang Moon;Kim Kyung Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.64-68
    • /
    • 2005
  • In this study, the smoke flows of the inner subway station were visualized through a numerical analysis and visualization experiment in the subway fire. A transparent acrylic model was designed and installed as 1:25th scale-down as the actual subway station by using geometrical similarity The properties of subway fire were reconstructed according to Densimetric Froude Similarity. The 47 to 53 ratio of the mixed air and Helium was inputted in the inner acrylic model to describe 1MW fire intensity with reference to the experiment paper. For the same time, the fire smoke from a smoke generator was inputted in the inner acrylic model with the mixture. At this time, the buoyancy effect of Helium gas went up the smoke to the acrylic model. When the sheet beam of Ar-lon laser was given out to the top and stair of subway model, the digital camcorder took the images of the scattered cluster of smoke particles when applying the smoke management system and PSD.

  • PDF

A Study on the Smoke Movement by the Opening and Heat Generator Position (개구부와 열원의 위치에 따른 연기이동에 관한 연구)

  • 조성우;이재윤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.7-14
    • /
    • 2002
  • The diffusion characteristics of the smoke by effect of an ascending air movement in a local part of the room where heat generated was studied. How the smoke move in the limited parts of the room at which heat generated was studied through 3 cases altering locations of inlet and outlet of ventilated air and heat generated by CFD(Computational Fluids Dynamics) method. It was found that 1. Similar distribution of air velocity, air temperature and smoke concentration appeared in the case of upper left inlet and lower right outlet and the case of lower inlet and upper right outlet. 2. Distribution of temperature and smoke concentration was 0∼0.3, 0.06∼0.14 in the case of lower left inlet and upper right outlet. 3. the location of heat generation did not influence on the temperature distribution, but influence on the distribution of smoke concentration.

A Study on the Early Fire Detection based on Environmental Characteristics inside the Nacelle of Wind Turbine Generator System (풍력발전기 너셀 내부 환경특성을 고려한 화재 조기감지방법 연구)

  • Kim, Da Hee;Lim, Jong Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.9
    • /
    • pp.847-854
    • /
    • 2014
  • The paper presented a method of early fire detection based on the environmental characteristics inside the nacelle of wind turbine generator system(WTGS). The rising rates of the temperature and smoke density were used as the parameters for early fire detection. By considering the characteristics of temperature and smoke density of a nacelle, this method is very reliable and can minimize the possibility of a malfunction of fire detection. The performance of the method was tested through sets of experiments by using nacelle simulator.

Design and testing of a low subsonic wind tunnel gust generator

  • Lancelot, Paul M.G.J.;Sodja, Jurij;Werter, Noud P.M.;Breuker, Roeland De
    • Advances in aircraft and spacecraft science
    • /
    • v.4 no.2
    • /
    • pp.125-144
    • /
    • 2017
  • This paper summarises the design of a gust generator and the comparison between high fidelity numerical results and experimental results. The gust generator has been designed for a low subsonic wind tunnel in order to perform gust response experiments on wings and assess load alleviation. Special attention has been given to the different design parameters that influence the shape of the gust velocity profile by means of CFD simulations. Design parameters include frequency of actuation, flow speed, maximum deflection, chord length and gust vane spacing. The numerical results are compared to experimental results obtained using a hot-wire anemometer and flow visualisation by means of a tuft and smoke. The first assessment of the performance of the gust generator showed proper operation of the gust generator across the entire range of interest.