• 제목/요약/키워드: small-scale school

검색결과 808건 처리시간 0.029초

Oxidation of Fe-(5.3-29.8)%Mn-(1.1-1.9)%Al-0.45%C Alloys at 550-650 ℃

  • Park, Soon Yong;Xiao, Xiao;Kim, Min Ji;Lee, Geun Taek;Hwang, Dae Ho;Woo, Young Ho;Lee, Dong Bok
    • Corrosion Science and Technology
    • /
    • 제21권1호
    • /
    • pp.53-61
    • /
    • 2022
  • Alloys of Fe-(5.3-29.8)%Mn-(1.1-1.9)%Al-(0.4-0.5)%C were oxidized at 550 ℃ to 650 ℃ for 20 h to understand effects of alloying elements on oxidation. Their oxidation resistance increased with increasing Mn level to a small extent. Their oxidation kinetics changed from parabolic to linear when Mn content was decreased and temperature was increasing. Oxide scales primarily consisted of Fe2O3, Mn2O3, and MnFe2O4 without any protective Al-bearing oxides. During oxidation, Fe, Mn, and a lesser amount of Al diffused outward, while oxygen diffused inward to form internal oxides. Both oxide scales and internal oxides consisted of Fe, Mn, and a small amount of Al. The oxidation of Mn and carbon transformed γ-matrix to α-matrix in the subscale. The oxidation led to the formation of relatively thick oxide scales due to inherently inferior oxidation resistance of alloys and the formation of voids and cracks due to evaporation of manganese, decarburization, and outward diffusion of cations across oxides.

Development of a special thermal-hydraulic component model for the core makeup tank

  • Kim, Min Gi;Wisudhaputra, Adnan;Lee, Jong-Hyuk;Kim, Kyungdoo;Park, Hyun-Sik;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1890-1901
    • /
    • 2022
  • We have assessed the applicability of the thermal-hydraulic system analysis code, SPACE, to a small modular reactor called SMART. For the assessment, the experimental data from a scale-down integral-test facility, SMART-ITL, were used. It was conformed that the SPACE code unrealistically calculates the safety injection flow rate through the CMT and SIT during a small-break loss-of-coolant experiment. This unrealistic behavior was due to the overprediction of interfacial heat transfer at the steam-water interface in a vertically stratified flow in the tanks. In this study, a special thermal-hydraulic component model has been developed to realistically calculate the interfacial heat transfer when a strong non-equilibrium two-phase flow is formed in the CMT or SIT. Additionally, we developed a special heat structure model, which analytically calculates the heat transfer from the hot steam to the cold tank wall. The combination of two models for the tank are called the special component model. We assessed it using the SMART-ITL passive safety injection system (PSIS) test data. The results showed that the special component model well predicts the transient behaviors of the CMT and SIT.

Boost-Half Bridge Single Power Stage Configured PWM DC-DC Converter for Residential PEFC Stack Interface.

  • Khairy, Fathy;Choi, Kwang-Ju;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.132-134
    • /
    • 2006
  • This paper presents the design and implementation of 1 kW prototype DC-DC power converter with bridge voltage-doubler suitable for small scale PEM fuel cell system and its associated control scheme. The operation principle of this converter is described using some operating waveforms and the switching mode equivalent circuits based on simulation results and a detailed circuit operation analysis and soft-switching conditions.

  • PDF

Fundamental study on volume reduction of cesium contaminated soil by using magnetic force-assisted selection pipe

  • Nishimura, Ryosei;Akiyama, Yoko;Manabe, Yuichiro;Sato, Fuminobu
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.26-31
    • /
    • 2021
  • Advanced classification of Cs contaminated soil by using a magnetic force-assisted selection pipe was investigated. A selection pipe is a device that sort particles depending on their particle size, based on the relationship between buoyancy, drag, and gravity force acting on the particles. Radioactive cesium is concentrated in small-particle size soil components with a large specific surface area. Hence, the volume of the Cs contaminated soil can be reduced by recycling the large-particle size soil components with low radioactive concentration. One of the problems of the selection pipe was that the radioactive concentration of the stayed soil in the selection pipe exceeds 8000 Bq/kg, which is the standard value of recycling of Cs contaminated soil, due to low classification accuracy. In this study, magnetic fields were applied to the lab-scale selection pipe from upper side to improve the classification accuracy and to reduce the radioactive concentration of the stayed soil.

A Study on a New Approach to Robust Control and Torque Control Response Analysis of Manufacturing robot Based on Monitoring Simulator for Smart Factory

  • Kim, Hee-Jin;Kim, Dong-Ho;Jang, Gi-Won;Gu, Byeong-Hwa;Han, Sung-Hyun
    • 한국산업융합학회 논문집
    • /
    • 제24권4_1호
    • /
    • pp.397-409
    • /
    • 2021
  • This study proposes a new approach to implimentation of robust control and torque control response analysis based on monitoring simulator for smart factory. According to the physical properties of a flexible manipulator, a two time-scale approach, namely, singular perturbation ap proach, is further utilized for thorough analysis and general controller design. It is shown that asymptotic motional tracking can be effectively achieved, whereas the force regulation errors can be made arbitrarily small. For demonstration of the proposed technology performance, experiments of a eight joint flexible manipulator are performed for the proposed control method, and the reliability of proposed control results are illustrated based on monitoring simulator.

SSC(Small-Scale Chemistry)실험이 과학영재의 과학적 태도, 창의적 성격 특성 및 과학탐구 능력에 미치는 효과 (The Effect of SSC(Small-Scale Chemistry) Lab Program on Scientifically Gifted Students' Scientific Attitude, Creative Personality Characteristics and Science Inquiry Skills)

  • 유미현
    • 영재교육연구
    • /
    • 제20권2호
    • /
    • pp.487-502
    • /
    • 2010
  • 이 연구의 목적은 SSC 실험을 과학영재 수업에 적용한 후 얻을 수 있는 효과를 조사하는 것이다. 연구 참여자는 대학부설 과학영재교육원에 선발되어 교육받고 있는 15명의 중학생 과학영재 학생이다. SSC 실험 프로그램은 3개월간 5가지 주제로 적용되었다. 연구 설계는 단일집단 사전-사후 설계였으며 PASW 18 통계 프로그램을 사용하여 데이터를 분석하였다. 본 연구의 결과는 다음과 같다. 첫째, SSC 실험은 과학영재 학생의 과학적 태도를 통계적으로 유의미하게 향상시켰다(p<.01). 특히 과학적 태도 하위 영역 중 '협동성', '자진성', '끈기성' 영역에서 사전검사와 사후검사 점수 간에 통계적으로 유의미한 차이가 나타났다. 둘째, SSC 실험은 과학영재 학생의 창의적 성격 특성을 통계적으로 유의미하게 향상시켰다(p<.01). 특히 창의적 성격 특성의 하위 영역 중 '집착성' 영역에서 사전검사와 사후검사 점수 간에 통계적으로 유의미한 차이가 나타났다. 셋째, SSC 실험을 적용하기 전과 후에 과학영재 학생의 과학탐구 능력에서는 유의미한 차이가 나타나지 않았다(p>.05). 연구 결과는 SSC 실험이 과학영재 수업에 효과적인 프로그램임을 시사한다.

Modeling of a Compressed Air Energy Electrification by Using Induction Generator Based on Field Oriented Control Principle

  • Vongmanee, Varin;Monyakul, Veerapol
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1511-1519
    • /
    • 2014
  • The objective of this paper is to propose a modelling of a small compressed air energy storage system, which drives an induction generator based on a field-oriented control (FOC) principle for a renewable power generation. The proposed system is a hybrid technology of energy storage and electrification, which is developed to use as a small scale of renewable energy power plant. The energy will be transferred from the renewable energy resource to the compressed air energy by reciprocating air compressor to be stored in a pressurized vessel. The energy storage system uses a small compressed air energy storage system, developed as a small unit and installed above ground to avoid site limitation as same as the conventional CAES does. Therefore, it is suitable to be placed at any location. The system is operated in low pressure not more than 15 bar, so, it easy to available component in country and inexpensive. The power generation uses a variable speed induction generator (IG). The relationship of pressure and air flow of the compressed air, which varies continuously during the discharge of compressed air to drive the generator, is considered as a control command. As a result, the generator generates power in wide speed range. Unlike the conventional CAES that used gas turbine, this system does not have any combustion units. Thus, the system does not burn fuel and exhaust pollution. This paper expresses the modelling, thermodynamic analysis simulation and experiment to obtain the characteristic and performance of a new concept of a small compressed air energy storage power plant, which can be helpful in system designing of renewable energy electrification. The system was tested under a range of expansion pressure ratios in order to determine its characteristics and performance. The efficiency of expansion air of 49.34% is calculated, while the efficiency of generator of 60.85% is examined. The overall efficiency of system of approximately 30% is also investigated.

소고기의 유통 단계별 병원성 미생물 오염도에 관한 연구 (A study on the contamination level of pathogenic microorganisms in beef distribution stages)

  • 박성도;김용환;고바라다;김철희;윤병철;김조균
    • 한국동물위생학회지
    • /
    • 제25권2호
    • /
    • pp.117-126
    • /
    • 2002
  • Contamination levels of pathogenic microorganisms in 145 cases of beef, which were distributed in Gwangju province, had been investigated in each distributed stage and also monitored by general bacterial count and E coli count index. General bacterial count of beef from the slaughterhouse was 10$^4$cfu/g less than the level of promotion(10 cfu/$\textrm{cm}^2$) and E coli count index was also under the level of 10$^2$cfu/$\textrm{cm}^2$ recommended level of the ministry of agriculture and forestry. Pathogenic microorganisms were detected from 23.2% of samples in the consumption stage, 12.5% in the slaughtering stage and 5.6% in the transporting and processing stage. Staphylococcus aureus was isolated in the largest number and its ratio was 9.0%, listeria monocytogenes 5.5% and salmonella spp 1.4%. There were no samples that bacteria had been detected dually. E coli O157:H7 and campylobacter jejuni were not isolated. In raw and chilled beef, isolation rate of pathogenic microorganisms were 13.3% and 16.5% each. Especially in raw beef, L monocytogenes was. isolated in 3 samples among 30 cases (10%) and S aureus in one sample (3.3%). According to a scale of meat store, isolation rates of pathogenic microorganisms were different. It was 28.6% in the small-scale meat store and 16.7% in the large-scale meat store each. Four cases (16.7%) of S aureus were isolated in the large-scale meat store and seven cases (20.0%) of L monocytogenes and 2 cases (5.7%) of salmonella spp were isolated in the small-scale meat store. S aureus was isolated in two places among 10 feeding facilities of the elementary school. This result shows that the sanitation of elementary school feeding facilities is so poor and more careful policy consideration is needed. Eleven strains of S aureus isolated showed ${\beta}$-hemolysis on blood agar, 1 strain ${\alpha}$-hemolysis, and 1 strain ${\gamma}$-hemolysis. Isolated strains of L monocytogenes were reconfirmed in 560 bp by PCR. Conclusively, these results show that the sanitary condition in the stages of slaughtering, transportation-processing and consumption influences the degree of pathogenic microorganisms contamination in beef severely It is necessary to apply thoroughly hazard analysis critical control point in a process of beef distribution and also to develop rapid test methods for microorganism diagnosis. This effort is very important for the supply of safe and clean meat from farm to table and helpful for the improvement of public health.

중소 종합병원 입원환자와 간호사의 간호서비스에 대한 기대와 지각, 질 평가와 만족도 차이 (The Differences in Quality Perceptions, Expectations, Evaluation, and Satisfaction for Nursing Service between Patients and Nurses: Small-medium Sized General Hospitals)

  • 김정희;이인숙
    • 대한간호학회지
    • /
    • 제34권7호
    • /
    • pp.1243-1254
    • /
    • 2004
  • Purpose: This study was performed to give direction to quality improvement strategies of nursing services by comparing the differences in quality perceptions and satisfaction for nursing services between patients and nurses in small-medium sized general hospitals with 200 beds. Method: The subjects, who were 150 inpatients and 162 nurses of 4 general hospitals in a community, answered a self-report questionnaire with a SERVQUAL scale. Result: There were differences between patients' and nurses' expectations and perceptions of nursing service and satisfaction. In the service expectation, the highest factor was 'the responsiveness', and in the perceived performance, the highest was the 'assurance'. In addition, overall patients' perceptions on nursing services showed higher than nurses'. There were positive correlations among the expectations and perceptions on nursing service, and satisfaction. The correlation between perception and satisfaction was higher than the correlation between expectations and satisfaction. Conclusion: To improve the nursing service quality at small-medium hospitals, strengthening the 'assurance' factor and improving the nursing service support system is needed. Also, this study on nurses' perceived nursing service at small-medium sized hospitals should be duplicated.

진동대실험을 통한 축소 아치구조물의 고유진동주기 분석 (Natural Vibration Period of Small-scaled Arch Structure by Shaking Table Test)

  • 김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제15권4호
    • /
    • pp.107-114
    • /
    • 2015
  • Large spatial structures can not easily predict the dynamic behavior due to the lack of construction and design practices. The spatial structures are generally analyzed through the numerical simulation and experimental test in order to investigate the seismic response of large spatial structures. In the case of analysis for seismic response of large spatial structure, the many studies by the numerical analysis was carried out, researches by the shaking table test are very rare. In this study, a shaking table test of a small-scale arch structure was conducted and the dynamic characteristics of arch structure are analyzed. And the dynamic characteristics of arch structures are investigated according to the various column cross-section and length. It is found that the natural vibration periods of the small-scaled arch structure that have large column stiffness are very similar to the natural vibration period of the non-column arch structure. And in case of arch structure with large column stiffness, primary natural frequency period by numerical analysis is very similar to the primary natural frequency period of by shaking table test. These are because the dynamic characteristics of the roof structure are affected by the column stiffness of the spatial structure.