Visual Performance Evaluation of Daylighting System with Sloped Lightshelves (광선반 채광시스템의 시각적 성능 평가)

  • Kim, Jeong-Tai;Shim, In Bo
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.3-10
    • /
    • 2006
  • This study assessed the visual performance of luminous environment by the lightshelf. The subject survey method was used and results are presented and analyzed. The lightshelf daylighting system was developed by LAEL at KH University and was applied on the window of a mock-up office. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. The experiment was conducted during the bright part of the day from noon to one thirty on June 7, 2006. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. During the experiment was carrying out, the work plane illuminance and luminous distribution at surrounding the windows was measured. The semantic differential rating data of experiment were analyzed by t-test and factor analysis using SPSS 12.0 statistics package. The visual performance of the lightshelf was more positive. The factors affecting the visual performance are task performance and visual comfort. The subjects were more comfortable in a room installed with lightshelves on both the task performance and the visual comfort aspect. Therefore, the application of sloped lightshelf daylighting system improves visual performance of luminous environment.

Development and Performance Evaluation of a Sloped Lightshelf Daylighting System (Mock-up model을 이용한 경사형광선반 채광시스템의 개발 및 채광성능평가에 관한 연구)

  • Kim, Jeong-Tai;Kim, Ki-Cheol;Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.39-50
    • /
    • 2004
  • One of the challenge for successful daylighting design might be to capture sunlighting that varies in both intensity and position and to deliver the luminous flux into the inner space as deep as possible. Conventional glazing apertures allow daylight in the outer 3.5m of a perimeter spaces. More advanced daylighting technologies can extend this daylighting depth by reflecting sunlight further from the windows within a deep floor area. For this purpose, this study developed light shelves based on performance evaluation with a mock-up model that constructed recently and measured under real sky condition. All these daylighting devices have a customized geometry developed from the solar path at a given latitude and utilize unique reflecting finishing to maximize the amount of redirection and diffusion of the daylight. This paper tells that the best daylighting penetration typically can be expected from using light-colored sloped external shelves.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.